Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
,~_ ~l""'lE
/ ~":~." j~~!~~;,~~
"C' li'" ,~ V"
"''':i~!.:~
- :.~~~.
Project number
~.._---
Release dale
08/02/07_
I Occupancy classification
TOWNHOUSE
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/S-98)
Report Printed on: August 2, 2007
327744
Construction type
V.S
Scope of release
ARCH ELEC FDN MECH
PLUM STR
'" INDIANA 02
)Jj..~. F 0000
~S
gJr
, HllOSI~R SAFE'!'i
Type of release
Standard
--
Project name
Townhomes at Guilford
Available At Your Local Licence Branch
SUPPORT HOOSIER SAFETY
To: Owner I Architect I Engineer
Pulte Homes
Wolfgang B Dorsch AR10200014
100 bloomfield Hills Pkwy
Bloomfield Hills MI 48304
Street address
11731 ~ 11743 Yale Drive
City I County
Fax & e-mail: 2489885008, wolfgang.dorsch@pulte.com Carmel HAMILTON
I ;._______
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans andlor specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error. in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date,
CONOITIONS,
Note :(A 1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class 0 felony punishable by a prison term and a fine up to $10,000.
in accordance with Section 19 of the General Administrative Rules (675 lAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
50
500317A
5003178
500317C
5003170
500807A
500309A
5D0309B
BUILDtNG 18
THIS PROJECT HAS BEEN REVIEWED UNDER THE 2005 INDIANA RESIDENTIAL CODE
Townhouses shall be separated by fire-resistance rated wall assembly in accordance with Section
R317.2, tRC (675 lAC 14-4.3).
Each individual townhouses shall be structurally independent in accordance with Section R317.2.4,
IRC (675 lAC 14-4.3).
Townhouse common walls shall be continuous from the foundation to the underside of the roof
sheathing, deck, or slab, and shall extend the full length of the common wall in accordance with
Section R317.2.1, IRC (675 lAC 14-4.3).
Parapets shall be provided for townhouses as an extension of the common wall in accordance with
Section R317.2.2, tRC (675 lAC 14-4.3).
Attic access shall be in accordance with Section R807.1, IRC (675 lAC 14-4-3).
Permitted openings between the garage and residence shall be equipped with solid wood, or solid
or honeycomb core steel doors not less than 1-3/8 inches thick or 20-minute fire-rated doors in
accordance with Section R309.1, IRC (675 lAC 14-4.3).
Garages shall be separated from the residence and its attic areas by a smoke separation of not less
than 1/2-inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be
separated from all habitable rooms above by not less. than 5/8 inch Type X gypsum board or
equivalent. The structure supporting the separation shall also be protected by not less than 1/2 inch
gypsum board or equivalent in accordance with Section R309.2, tRC (675 lAC 14-4.3).
Page 1/2
Wuuld you like to reduce your turnaround time?
ELECTRONICALL Y FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/firefbranchesfplan_reviewfindex.htm!.
This oll.line filing is throLJgh a secure site. you can use it to submit your project information, pay the fees and upload your project plans.
I',:' oi Jul'" 1 200-:- '!Ii! ",xlstlng e-f)j~ slle e.E i It?24 - 7@dijS. in. go,.' Will HO JUll~et b~ lil SlJr'IIc..~.
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above-
stated dale. unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter, If you
choose to petition, and the before-mentioned procedures are followed. your petition for review Will be granted. and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed. this Order will
be final. and you must comply with its requirements.
Filed By
I Code review official
FRED BENNETT
Code Enforcement & Plan Review Branch Director
Address (name,title of local official,street,city,state and ZIP code
BUILDING COMMISSIONER
CHARLES KIPHART
ONE HAMILTON SQUARE SUITE 138
NOBLESVILLE, IN 46060
~-
State Fire Marshal
v~d6~
War 0 ~
I
Lfax & e-mail: 3177742559! cek@co.hamilton.in.us
Page 2/2