HomeMy WebLinkAbout07080173 Site Plan
She Schneider CarpereUon 61littneerloy
0901 Otis Avenue sm"0118
Historic Part Harrison landscape Arebttecdue
lndlmepolls, Indic.. 40216-1037 0L4 • W
917-020-7100 Geala®
Sclyw
id
317-026-7200 PAX
...
Plot Plan Prepared far. R.H. of Indiana
BLOCK 4 LOT 287(404) containing 1,340 S.F.i in plo t Wan Legend
Stanford Park Section 13
Instndment / 200500009386 ? Proposed Grades
P.C. ¢ 3 Slide / 578 000ooo.0.o-
? Contour Grades
Grade
Amended Plat * Approx. Lateral Location
Instrument # 20050003471 - a- Sanitary Sewer Lines
P.C / 3 Side 637 - v -
- v - Storm Sewer Lines
Water Service Lines
Clay Tarp, Hamilton Colmty - - - - - - - Sub-Surface Droin Lines
See 20, T29K HE O Manhole (Sanitary or Storrs)
13304 Golden'Gate-Drive-West (24'R/W) 0- -
®
{Sr)'
9eehPNrlIntel (nletStorm)
Curb
Carmel, IN 46074 D End Section (Storm)
Pied Data 08/03/07 By. AMA A Fire Hydrant
Pmpowd BU 8y INVENTORY - Flow Line of swale
Building Line (BL / BSL)
- - - - - - - Easement Line
Community Restrictions:
Side Yard =3' min.
Rear Yard = N/A
Aggregate = 6' (B.H.)
Note:
This drawing is based on construction plans or record drawings,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately, failing to do
so results in the contractors assumption of oil liability.
LOT# 287(404)
Vb07.0077360
0
°m-
0
Assumed North
Scale : l' - 20'
STR. #713
TC=916.38 i
PER RECORD
DRAWING
Q
O
' 3: J
m
rr
\ of a fd:aDEICf Is oJI VOR W%iplxiY uIE i
LL' Z 8.7 63
65 .
.
z ;r, I LK o .
O Lq
J
m v W
a ai O
O W
.dW
V
7 O
°
?'
07
W 1
mI Up
W
?? ?-
d ?1
' v
r
S
. UPI ¢? ¢ 0.9
n
'
'
(/7 ° WAI n 71 71
38.75
¢ r,_,
2
STR. #71
TC=913.06
(
PER RECORD
FLOOD HAZARD STATEMENT DRAWING
CERTIFICA TION
Note: Per Carmel toning ordinance 26.1.1 : the
residential district limits height to twenty-five feet
(25), however a dwelling may be increased in height
to thirty-five feet (357 provided the side and rear
lards ore increased an additional one fool (1') for
each we fool (I") the structure exceeds the first
twenty-five feet (25') in height
Note:
The contractor is to maintain a minimum
distance of ten feet (10') between the
mnitry sewer and water line laterals
NOTE:
Builder to ensure positive
drainage away from structure(s).
This drawing is not intended to be represented as a retracemenl or
original boundary survey, a route survey, or a Surveyor Location Report.
Flood Hazard Staternam: The accuracy of any flocd hazard data shown on this report is subject to map
scale uncertainty and to any other uncertainty in cation or elevation on the referenced flood insurance rate
map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land
plots by scale cn flood insurance rate map r 16057 0205E fur City of Cannel, Indiana (mans cated Feoruary
19, 20031.
SIGNATURE : DATE:
SIGNATURE REPRESENTS ODNFIRMATION OF RECEIPT OF PLOT PLAN BY CUSTOMER
H
H--
Cn
W
w
W Z
O-' w
? rn
w
Q N
c?
z
W
Y
J O
C) Tt` m
R.H. of Indiana
Finished Floor Elevation Information
Pad Grade = 916.0 per plan
Pad Grade + 0.7' = Garage FIFE (9163)
Garage FFE + 0.5' = Residential FFE (917.2 )
Note: Sanitary Sewer
Top of Costing Information
Upstream Manhole, TC=916.38
Downstream Manhole, TC=913.06
per record drawing
Grand Cow Calmlations:
Drive = 346 SFt
Privale Walk - 30 SFt
Sod = 36 SYt , entire yard
3
a• ° apc
Opp y1
TYPICAL SHALE SECTION
1??' ?_. T