Loading...
HomeMy WebLinkAbout07080014 Site PlanThe Scboelder Cazponuao an Due Avenue Historic Fort Nmrieoo fadlampall, , ladiem {6218-]067 517-0216-7100 317-828-7200 VAX This Plot Plan Prepared For. MA Homes Lot # 38, containing10,000 S.F.t, in Heather Knoll section 11 Instrument /200500003045 P.C. 3, Side 560 Cloy Towship, Hamilton County SEC 20, T18N, R03E 14235 Camden Lane ( 50' R/W) Westfield, IN 46074 Prepared Date: 07/13/07: By AMA Community Restrictions: Side Yard = 3' min. Aggregate = 6' B.H. Zoning - SI bomtml Sturnybell Note: This drawing is based on construction plans or record drawings, readecepe Architecture and is not based upon a field survey. The Schneider Corporation GIs • Us does not warrant the accuracy or sufficiency of this information amlap - Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately, fading to do so results in the contractors assumption of all liability. Rot Plan Leoend I Proposed Grades 000.0 Existing Grades ?000.0? Contour Grade # Approx. Lateral Location - e - Sanitary Sewer Lines K - Storm Sewer Lines - v - Water Service Lines - - - - - - - Sub-Surface Drain Lines • Manhole (Sanitary or Storm) ® Beehive Inlet (Storm) IN Curb Inlet (Storm) D End Section (Storm) Fire Hydrant - . o = - . - Flow Line of swole - Building line (81. / BSL) - - - - - - - Easement Line M/i HOMES STR. 4 Tog Pad Grade = 918.1 per plan TC=9 7.54 PER RECORD Pad Grade + 0.2' = Garage FFE (918.3) DRAWING Garage FFE + 0.5' = Residential FFE (91118 ) Residential FFE - 9.0' = Basement FFE (909.8 ) Driveway Slope = 2.5% STR 706 TC- 6.98 CORD DDRAMWGG 0 ?PER. H-B i Note: Sanitary Sewer Top of Costing Information 36. Upstream Manhole, TC=917.54 26.0' / Downstream Manhole, TC=916.98 \ 190 per record drag. .6 / NOTE: GARAGE F.F.E. IS PROPOSED TO BE 0.9' ABOVE CURB AT DRIVEWAY T.B.M. GROUND COVER CALCULATIONS: L 97 Drive = 606 SFi '9 Public Walk =319 SFd Private Walk =N/A SF3 _ 16.5 Seeding =5,215 SFt ,qA Sod =272 SYt, from front of residence. FLOOD HAZARD STATEMENT CERTIFICATION s+, \`\\\\\`?\Y11111111111111f11????////// , p?? ?SS.GISLTEROIr'' °? S0303 STATE OF S CPC/` Note: The basmwnt devotion, depicted hereon, has lace ddennined and based an the pad grads and/or conloun taken ran the construction planar Ica this subdnitcn. Udesa stated, no nfamotfon about 0uctuaing water tables, eel conditions, or sal tees has been provided or staled on said plan. This lot is located nee a body of water. Lo or sW cancitlons may require that the bwanent floor elevation be held 2 foot above normal pod elevation. Site investigation may be needed it water is mcamlered during the movat'xin procea or it other known water elevation or sacs conditions ore present Investigation and my remedied procedure is at the d'metion of the builder to determine aM lake appropriate steps of action. If my ground water is enminlered Awing esrnwtion the builder is encouraged to contest The Schneider Corporation to disaa possible courses of action. NOTE: SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. Note: Builder to ensure positive drainage away from structure(s). Note.. The contractor is to maintain o minimum distance of ten feet (10') between the sanitary sewer and water line laterals. LOT If 38 VW7.0076791 ro '%38.r y? 2a7' \A6 / 12.2' i 5?t °LS?S° < 0 \ Assumed North \\ Scale : 1' = 30' %oo 0? 0 ? d• S? \4Q a \ t. \ O \\ , X i y ,5a\ \ "n /?. "? / / This drawing is not ini died to a represented as o retrocement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data show on this plot plan is subject to map scale uncertainty and to any other uncertainly in location or devotion on the referenced flood insurance rate map (FIRM} None of the within described land lies within that special flood hazard zone *A*. as said land plots by scale on Community Map Panel / 1800810001C of the flood insurance rate maps (FIRM) for Hamilton County, Indiana, Dated May 19, 1981. 40.3• v G O?c,.Q Pic, O • ?Q . Z o 1 SL2 f A Y SL_ pf TYPICAL SWALE SECTION NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1-