Loading...
HomeMy WebLinkAbout07080121 SewerCITY OF CARMEL 1 of 1 PERMIT RECEIPT OPERATOR: twedding COPY # : 1 Sec: Tim: Rng: Sub:B62 Elk: Loc:456 PARCEL ID ........: Z262456 DATE ISSUED.......: 08/22/2007 RECEIPT #.........: 26088 REFERENCE ID # ...: 07080120 SITE ADDRESS .....: 2184 TROWBRIDGE HIGH ST SUBDIVISION ......: VILLAGE OF WESTCLAY CITY .............: CARMEL IMPACT AREA ...... OWNER ............: SHAFFER ENTERPRISES ADDRESS ..........: P.O. BOX 374 CITY/STATE/ZIP ...: ZIONSVILLE, IN 46077 RECEIVED FROM ....: SHAFFER ENTERPRISES CONTRACTOR .......: LIC # XELITEX COMPANY ........... ELITE EXCAVATING ADDRESS ..........: 12413 BROOKS CROSSING CITY/STATE/ZIP ...: FISHERS, IN 46038 TELEPHONE ......... (317) 841-8951 ID UNIT QUANTITY AMOUNT PD-TO-DT ---- ------- ---------- ---------- ---------- :ONN FLAT RATE 1.00 1310.00 0.00 TAP FLAT RATE 1.00 86.00 0.00 ---------- ---------- PERMIT 1396.00 0.00 OF PAYMENT AMOUNT NUMBER ----------- ------------ ------------------ 1396.00 16207 ?ECEIPT 1396.00 THIS REC NEW SAL ---------- ---------- 1310.00 0.00 86.00 0.00 ---------- ---------- 1396.00 0.00 %. CITY OF CARMEL / CLAY TOWNSHIP Permit #: 07080120 WATER / SEWER PERMIT / RECEIPT Date: 08/22/2007 Mot! .. ANP- tCEL ID #: ZB62456 - & SUBDIVISION: 456 VILLAGE OF WESTCLAY )RESS OF CONSTRUCTION: 2184 TROWBRIDGE HIGH ST CARMEL, IN 46032 WENT RECEIVED FROM: te: SHAFFER ENTERPRISES CHECK #: 16207 'AVATOR INFORMATION: ie: ELITE EXCAVATING 1: (317) 841-8951 Fax #: Email: at Address: 12413 BROOKS CROSSING FISHERS, IN 46038 d Expiration: MIT TYPE: USEWRWATR ; SEWER/WATERPERMIT :ial Notes/Conditions: F 456 VILLAGE OF WESTCLAY D NOTES' wildine & Sewer Shall be five sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting d specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer be installed in accordance with .ASTM 2321 for pvc pipe and the Uniform Plumbing Code for the Stale of Indiana. Ali installations shall be ict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section '.(a), and sections P3008.1 and 2 of the International Residential Code. All building sewers shall be 6" diameter. st-llations shall be "open trench" inspected and approved by the Carmel Sewer Department before any backfilling is done. Non- liance may result in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections. oting or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer, inspections should be requested at (3 17) 571-2648 one to four hours in advance, rpections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All ers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street ie cut. a separate street cut nermit shall he ohtairiM. CANT NAME: RANDAL S. SHAFFER ENT RECEIVED B . ?? ?% .00 Regional Waste District Residential SANITARY SEWER PERMIT P0135 INDIVIDUAL LOT / EXISTING BUILDINGS Permit Type Final Lot Number 456 Lift Station 19 Village of West Clay Station Address Number 2184 Treatment Plant MIX Subdivision Village,of West Clay Section Number 5001 Builder Shaffer Ent Street Trowbridge High St City Carmel Zip Code 46032 County Hamilton Parcel Acreage Plan Review and Inspection Employees Application Fee $100.00 I. Square Footage EDU Fee $1,650.00 EDU 310 Interceptor Fee Invoice Number Fees Due $1,750.00 'EASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste strict (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during pen trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, other sources of ground or, stormwater, shall be permitted.to enter the District's' sanitary sewer system. The District Il assume'no liability _for drains which are below the grade. level of the nearest' downstream manhole nor for laterals iich are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be ponsible for damages to the District's'sewer'system. This includes damages to manftoles, castings, manhole lids dthe like, caused by construction activity on the building site which is the subject of this permit. 'pections by the District are MANDATORY and shall be'arranged by contacting the District's office at 844-9200 'hours'in advance. All,new construction will be placed on billing six months.after connection has been made or when ter, is connected, whichever comes first. Up VWC432 VW13431 bown building has a: Grease'Trap No Slab Foundation No Lid Elevation .903.52 ft' 902.03 ft Grit Interceptor No Crawl Space No First. Floor Elevation 906.50 ft. 906.50 ft Grinder Station No Basement Yes- Basement Elevation 896.50 ft 896.50 ft 'Calcuialion is based on both Manhole Lid Elevations and the elevation of the. First Floor f_ 2.98 4.47 Irdinance9-13-99 and. the elevations provided, the substructure shall be plumbed by: xPlumbed' with Grinder Pump Installed he District reserves the right to inspectall sump pump connections to ensure no illegal connections have been made. ???-"""Manholes. shall remain accessible at all times. Buried manholes will be corrected by the Developer/,Owner. Conditional' Permit Terms: Plans Submitted No Two sets of plans showing at least one sanitary manhole and top of casting elevation No Connection No NO CONNECTION to the sewer until further nofification. Certificate of Insurance No Certificate of Insurance must be on file with CTRWD' listed as certificate holder. Inspection Notice No 48 hours nofice before.work starts on manhole core drilling or cuts of active lines Fees Paid No, All District fees will be paid in full. Plan Review No ?rx'`Nq` Approval pending Districts review of plans. F511V ? r O?. Other Permits No Copies of approved permits from appropriate county on c ncies C NoOccupancy No No occupancy until further notification ( Fats, Oils & Grease No Fats, Oils and GreaseFacilities willabide by District stan 2rd Manhole Core _ "`vnJNAL'W ping below, 1 attest that I am f miffar wit, the Distr?s"ecifica ions n agr to accept responsibility for all work done under this. permit. -r / Owner Signatu Phone Number Printed Nam Permit.Date 8/112007 ?6/07 Permit is valid for ONE-YEAR from the.date issued. Permit valid only with CTRWD seal in red ink. SUMMARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90:days of notice providir sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building r connect to the sewer main per lateral unless otherwise approved by the District. 2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected the District's sanitary sewer. 3. The existing sewer line from the building to the septic tank may only be used if it is located under a building 'addition, patio, porch'orpaved driveway. Air test is required to show if acceptable for re-use. The property owne shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test. 4. The owner or contractor shall notify the District prior to covering the installed lateral sb that the District can ma inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 h prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is no site for scheduled inspection; cr fails to cancel inspection, an additional fee of $100.00 will be due., This must be prior to the time of the follow up inspection. 5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenanc private sewage disposal (septic) systems. The County. Ordinance provides in part that, upon connection to a pul 'sewer, aseptic tank "...stiall be abandoned (pumped clean) and filled completely with earthen material or stone; safe and sanitary manner." Please contact the appropriate County Board of Health for further information and tc the department of the abandonment. 6. Acceptable Pipe. Materials: PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21, ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer) GA:SKETED JOINTS:.ASTM D3212 GASKETS: ASTM F477 FITTINGS: SDR 26'or better (NO fernco's allowed) DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE FOUNDATION AND NO MORE THAN 100 FEET APART. 7. Bedding.Use Number 8 crushed stone or Number8 fractured face aggregate. Number8 stone backfill mat be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wic inches on both sides of the pipe) 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC.pressure grade pipe is used;, SDk21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepter District and the Districts engineer prior to installation. , 9. Where a transition is made between SDR'35 pipe and pressure grade SDR 21 pipe, a ductile iron gaskete mechanical coupling shall,be used. 10. Laterals shall terminate within .3 feet of the building unless the conditions in item #3 above are met. No c shallbe installed outside three feet of building foundation walls. 11. Additional information on'District standards and specifications maybe obtained from the District's office i business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our' at http_:/Mrvw.ctrwd.org/. Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280 12. Septic effluent shall not be pumped out into the sanitary sewer system. 13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours'prior to time d 14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be-placed on top of tt The.District inspector will verify placement of the wire. After inspection, bedding is to be placed on top. 15. Call before you dig. IUPPS 1-800-382-5544, 48 hours, prior to digging Ri A° Group nd Surveyors 'est Carmel Drive, Carmel, IN 46032 7.844.3333 F 317.844.3383 n/ww.seagroupllc.com IT PLAN WAS 0 BASED ON TION TAKEN FROM PLATS, SUBDIVISION lECORD DRAWINGS ANS PROVIDED BY T IS THE IIBILITY OF THE :TOR TO VERIFY SITE NS PRIOR TO ICTION AND NOTIFY A GROUP LLC and { OF ANY kNCIES. LOCATION OF UTILITIES ON NOTE: (SECONDARY AREAS NOTE: PAD ELEVATION PLOT PLAN ARE GENERAL - WESTCLAY) MAX. HEIGHT: SHOWN IS PER PLANS AND LOCATIONS PER PLAN AND 35' ON LOTS 100' AND IS NOT THE AS-BUILT SHOULD BE VERIFIED IN THE LARGER (TO EVE LINE) 30' ELEVATION. FIELD. ON LESS THAN 100 MAX. COVERAGE: 50% I NOTE: (PRIMARY AREAS - WESTCLAY) MAX. HEIGHT: 30' BUILD-UP LINE: 2 STORIES MAX. COVERAGE: 50% 1 OF UTILITY S ON PLOT PLAN ERAL LOCATIONS N AND SHOULD BE IN THE FIELD. TO ENSURE POSITIVE IAY FROM RE. BE PLACED BY AS NEEDED. BUILDER IS TO ;IDEYARD SWALE TO SHOWN ON THIS F BUILDER IS TO ACHIEVE DRAINAGE AWAY tOPOSED 'RE, THE ENGINEER E CONTACTED. IS NOT TO DEVIATE LADES SHOWN ON 1N WITHOUT THE OF BOTH THE 2 AND BRENWICK. .LEVATIONS AND IDES DEPICTED ON )T PLAN IS OPEN IEW BY BRENWICK 'MENT. THE BUILDER ONED_THAT.SAID TION IS SUBJECT IGE. GRANULAR BACKFILL SUGGESTED UNDER DRIVEWAY AT SANITARY SEWER LATERAL TRENCH, WATER LINE TRENCH AND ANY OTHER EXCAVATED AREAS. (IF SITUATION OCCURS) G 3 LOCATION PER ICT10N PLAN S. CONFIRM BEFORE iCTION OF 6" f LATERAL AND ERVICE LINE. ? T DNCRETE APRON TO 1 XISTING ALLEY N PAVEMENT LOT# 456 6,500 S. F. IN STREETS FROM LEAVING LOT TO BE AT THE END OF Y. ;E TO BE USED EEDED TO KEEP OF STREETS AND iTORM SEWERS. WATER TAP TO BE :D WITH GRANULAR TO WITHIN 10" OF ;URS. =TAP ICE LA TERAL S AT CURB ARE SS= SANITARY 1= SUBSURFACE WATER MINIMUM SETBACKS = 3 Feel (S Feet Min. one sidel = 20 Feet I Feet fi J S' MIN. 6" 18.3 i2' ALLEY SAN. LAT. ESMT. CONC. DRI;r_ 905.1 1 GARAGE rro z o FFE=905.1 I m I J 18.00' I -4.67 f O O O I ?? N - - -' N? - -- - m ESMT I o -1 FFE=896.5± 0 c m o I U, ° O 1 0.67' . O ^' F PROPOSED m FRIA & MSY RESIDENCE FFE=906.5 NOTE: THE INFORMATION FOR THE ELEVATION DIFFERENCE BETWEEN THE PRIMARY FINISHED FLOOR ELEVATION TO THE TOP OF BASEMENT WALL AND TO THE BASEMENT FINISHED FLOOR WAS PROVIDED BY THE BUILDER. 00.0 PROPOSED GRADE GROUND WATER F1 -sw sw - SANITARY SEWER -sn rn - STORM SEWER UN -1IIR •TM- WATER LINE ---------------- EASEMENT LINE - - BUILDING SETBAO ? 1 _'•L 7 ?? P IN o a ou iv <n `- a SAN APPROX EDGE 12' ALLEY ESMT. r? OF PVMT. SAN -? 6A 50. APRON I v O o TJ ? ? N = o w a in 12.0' } WALK _TROWBRIDGE HIGH STREE_T_ ? 902.36 40' R/W -WIR I W W KR ty Description: nber 456 in Village of Westday, Section 5001, an Addition in Hamilton County, , as per plat thereof recorded as Instrument Number 200500019934 found in the f the Recorder of Hamilton County, Indiana. PLOT PLAN I"=20' July 25, 2007 Drawn by DJR ed: Prepared For: Shoffer Enterprises of Indiana Residence 2184 Trowbridge High Street .No.- LS20200083 STATE OF