HomeMy WebLinkAbout07080155 Site Planchn
The flob.,la corporal"
>uf?l Note:
99
01 Oth Armor
This drawing is based on construction plans or record drawings,
Itlatorla Fort Berrieon tamewpe Architect = and is not based upon a field survey The Schneider Corporation
li dlenepft fadlenn 46216-1037 ® • la does not warrant the accuracy or sufficiency of this information
317-886-7190 GO*O .
Contractors should verify existing conditions prior to any
317-6713"7200 FAX construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation Immediately,, failing to do
This Plot Plan Prepared For.
R.H. of INDIANA
Lot # 209 , containing 6,382
Stanford Park Sec. 2B
Instrument #200600049043
Plat Cabinet 4, Slide 126
S.F.t, in
Hamilton County, Clay Township
Sec. 29, T1BN, RX
13447 Cuppertino Lane (50' R/W)
Carmel, IN 46074
Prepared Date: 08/10/07 : By. AMA
Proposed Buyer(s): Darrel J k
Janet Forsman
Community Restrictions:
Side Yard = 3'
Rear Yard = N/A
Aggregate = 6' 8.1-1.
Zoning = R-2, ROSO
Finished Floor Elevation Information
Pad Grade = 916.7 per plan
Pad Grade + 0.7' = Garage FFE (917.4 )
Garage FFE + 1.5' = Residential FFE ( 918.9 )
Residential FFE - 9.0' = Basement FFE (909.9
Note : The garage finished floor elevation
is 27' above the curb at the drive, per
plan.
Sidewalk to be placed
ordine with property line,
5'from bad of curb,
per plan.
STR # 741
TC-917.94
PER RECORD
DRAWNG
r I
o I 30.0' I
- O
Ln I"
I IL J :?j I
I Z as 1?
I Q
I J I
I I
a 9150 I Z I
I-J-J
I
I U i S
I
sift. i 742 ' i
TC-915.53
PER RECORD rr
DRAWWG
Plat Plan Legend so results in the contractors assumption of all liability.
® RExisting Wsedtrad> Note:
? 00110 Contour Grade The basement elevation, depicted hereon, has been determined
'k APaMIL Lateral Location
-a- Sonla
Sewer Linea and based on the pad grades and/or contours taken from
ry
-a- storm 9ewe Lines the construction plans for this subdivision. Unless stated, no
- v - Water Servim Lkms Information about fluctuating water tables, son conditions, or
--- - sub-Surface Orate Urea sol types has been provided or stated In said plans. This ;lot
• M
anhole (Sanitary ar storm) is located near a bod
of w
ter
L
t
l
diti
GO&W at
cwb inlet (storm) () y
.
a
o
or so
con
ons may
require that the basement floor elevaton be held 2 fool
D End Swoon (Storm) above normal pod elevation. Site Investigation may be
Fire Hydrant needed If water is encountered during the excavation process
- • • • - • • • - Flaw Lre of new, or if other known water elevation or sal conditions are
present Investigation and any remedial procedures is at the
discretion of the budder to determine and take appropriate
Note: Sanitary Sewer steps of action. If any ground water is encountered during,
Top of Casting Information excavation the budder Is encouraged to contact The Schneider
Upstream Manhole, TC=915.53 Corporation to discuss possible courses of action.
Downstream Manhole, TC=917.94
per record drawing
UPSTREAM SANITARY MH NOTE
The upstream sanitary manhole
T.C. elevation shall be no less
than one foot (1'-0•) below
residential F.F.E.
Note: The contractor is to maintain
)a minimum distance of ten feet (16)
between the sanitary sewer and
water line laterals.
Ground Cover Calculations:
Drive = 496 SF±
Public Walk =145 SFt
Private Walk =49 SFt
Hydroseeding =n/o SFt
Sod =409 SYt ,
entire yard.
Note: Budder to ensure
positive drainage away from
structure(s).
Note: Sump pump(s) to be
placed by budder as needed.
LOT # 209
VB # 07.0078388
0
4m-
0
Assumed North
Scale: 1• = 30'
l 141./I o r
915.1 4.5'
y
-fi 3 117
e I gg
p 3 ?,y
l
C I 1
C) 39.4
5 o
915
l7
-C
c
>39 .
I- t2 d
-J 4'
N? U Y I ?
r N4.
914.9 915.4
o
r?
?
?
I?1 f
Z
Cx?I
n Its
n
FLOOD HAZARD STATEMENT
CERTIFICATION
?a• .??
v -
No.
sxURK : OAM
S0303
i S /.'• STATE OF
SIOURWE 9EP6ESO113 00161WIM OF KOEFT OF PLOT PUN BY CUSTO R °I aPF- %`q/ .HOI AN P.1QQ\\?
D ..SURV?
Note: This drawing is not intended to be represented as a retracement or TYPICAL swAIF secnaN giiillllit1p41
original boundary survey, a route survey, or a Surveyor Location Report.
Flood HazaldStatement The accuracy of any flood hazard data shown on this report Is subject
to map scale uncertainty and to any other uncertainty in location or elevation an the
referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within
that special flood hazard zone A as said land plots by scale on flood insurance rate map
118057C 0205F for the City of Cannel, Indiana (maps dated February 19, 2003).