Loading...
HomeMy WebLinkAbout07080155 Site Planchn The flob.,la corporal" >uf?l Note: 99 01 Oth Armor This drawing is based on construction plans or record drawings, Itlatorla Fort Berrieon tamewpe Architect = and is not based upon a field survey The Schneider Corporation li dlenepft fadlenn 46216-1037 ® • la does not warrant the accuracy or sufficiency of this information 317-886-7190 GO*O . Contractors should verify existing conditions prior to any 317-6713"7200 FAX construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation Immediately,, failing to do This Plot Plan Prepared For. R.H. of INDIANA Lot # 209 , containing 6,382 Stanford Park Sec. 2B Instrument #200600049043 Plat Cabinet 4, Slide 126 S.F.t, in Hamilton County, Clay Township Sec. 29, T1BN, RX 13447 Cuppertino Lane (50' R/W) Carmel, IN 46074 Prepared Date: 08/10/07 : By. AMA Proposed Buyer(s): Darrel J k Janet Forsman Community Restrictions: Side Yard = 3' Rear Yard = N/A Aggregate = 6' 8.1-1. Zoning = R-2, ROSO Finished Floor Elevation Information Pad Grade = 916.7 per plan Pad Grade + 0.7' = Garage FFE (917.4 ) Garage FFE + 1.5' = Residential FFE ( 918.9 ) Residential FFE - 9.0' = Basement FFE (909.9 Note : The garage finished floor elevation is 27' above the curb at the drive, per plan. Sidewalk to be placed ordine with property line, 5'from bad of curb, per plan. STR # 741 TC-917.94 PER RECORD DRAWNG r I o I 30.0' I - O Ln I" I IL J :?j I I Z as 1? I Q I J I I I a 9150 I Z I I-J-J I I U i S I sift. i 742 ' i TC-915.53 PER RECORD rr DRAWWG Plat Plan Legend so results in the contractors assumption of all liability. ® RExisting Wsedtrad> Note: ? 00110 Contour Grade The basement elevation, depicted hereon, has been determined 'k APaMIL Lateral Location -a- Sonla Sewer Linea and based on the pad grades and/or contours taken from ry -a- storm 9ewe Lines the construction plans for this subdivision. Unless stated, no - v - Water Servim Lkms Information about fluctuating water tables, son conditions, or --- - sub-Surface Orate Urea sol types has been provided or stated In said plans. This ;lot • M anhole (Sanitary ar storm) is located near a bod of w ter L t l diti GO&W at cwb inlet (storm) () y . a o or so con ons may require that the basement floor elevaton be held 2 fool D End Swoon (Storm) above normal pod elevation. Site Investigation may be Fire Hydrant needed If water is encountered during the excavation process - • • • - • • • - Flaw Lre of new, or if other known water elevation or sal conditions are present Investigation and any remedial procedures is at the discretion of the budder to determine and take appropriate Note: Sanitary Sewer steps of action. If any ground water is encountered during, Top of Casting Information excavation the budder Is encouraged to contact The Schneider Upstream Manhole, TC=915.53 Corporation to discuss possible courses of action. Downstream Manhole, TC=917.94 per record drawing UPSTREAM SANITARY MH NOTE The upstream sanitary manhole T.C. elevation shall be no less than one foot (1'-0•) below residential F.F.E. Note: The contractor is to maintain )a minimum distance of ten feet (16) between the sanitary sewer and water line laterals. Ground Cover Calculations: Drive = 496 SF± Public Walk =145 SFt Private Walk =49 SFt Hydroseeding =n/o SFt Sod =409 SYt , entire yard. Note: Budder to ensure positive drainage away from structure(s). Note: Sump pump(s) to be placed by budder as needed. LOT # 209 VB # 07.0078388 0 4m- 0 Assumed North Scale: 1• = 30' l 141./I o r 915.1 4.5' y -fi 3 117 e I gg p 3 ?,y l C I 1 C) 39.4 5 o 915 l7 -C c >39 . I- t2 d -J 4' N? U Y I ? r N4. 914.9 915.4 o r? ? ? I?1 f Z Cx?I n Its n FLOOD HAZARD STATEMENT CERTIFICATION ?a• .?? v - No. sxURK : OAM S0303 i S /.'• STATE OF SIOURWE 9EP6ESO113 00161WIM OF KOEFT OF PLOT PUN BY CUSTO R °I aPF- %`q/ .HOI AN P.1QQ\\? D ..SURV? Note: This drawing is not intended to be represented as a retracement or TYPICAL swAIF secnaN giiillllit1p41 original boundary survey, a route survey, or a Surveyor Location Report. Flood HazaldStatement The accuracy of any flood hazard data shown on this report Is subject to map scale uncertainty and to any other uncertainty in location or elevation an the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rate map 118057C 0205F for the City of Cannel, Indiana (maps dated February 19, 2003).