HomeMy WebLinkAbout07080219 Sewer / Water PermitRegional Waste District
1dential 4jr SANITARY SEWER PERMIT
I720 D1 INDIVIDUAL LOT/ EXISTING BUILDINGS
nit Type Final
division Saddlebrook aI Shelborne
ion Number
--- 1
--------------------------.----
Station -
- 16 Zionsville Presbyterian Station
- ...----------------------
tment Plant CTRWD VWVTP
' -------- --------------
der _ _ -
- Jones Building Group
ne Number 317-557-9443
:el Acreage
--------------------------------
in Gallons 310
ice Number
Lot Number
- ---------------- - 9
--
Address Number 3328
Street
---------------------- Homestretch Dr
----------------
City - --- - -Carmel
Zip Code 46032
County
- -------------------- _ Hamilton
------ -
Local Sewer Charge
Plan Review and -Inspection
Application Fee ---- ----------- $10000
EDU Fee 51,200:00
Interceptor Fee
Fees Due
4SE"NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
ict (see reverse) and any conditions noted below, All installations shall be inspected by District personnel during
n trench" phase and before backfilling with stone to twelve inches above the:pipe. NO footing or foundation
is, or other sources of ground or stormwater, shall be permitted.to enter the District's sanitary sewer system. The
ict will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
als which are extended beneath driveways or sidewalks. The.permit holder (property owner, developer or builder)
re responsible for damages to the District's sewer system. This includes damages to manholes, castings,
hole lids and the like; caused by construction activity on the building site which is the subject of this permit.
ections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
ours in advance. All new construction will be placed on billing six months after connection has been made or
a water is connected, whichever comes first.
building-has: USMH SBK-812 SBK-811 DSMH
ase Trap
------ No
------ Slab Foundation
- No Lid Elevation
- 905.56 ft 906.81 ft
-----------
Interceptor
-`- No-
----- Crawl Space No First Floor Elevation
- 909.00 ft 909:00 ft
-- -------- --------
-der Station No
- Basement
-------- Yes Basement Elevation
----- - 899.00 it 899.00 ft
--------- ----------
----
-----
I
Calculation is based on both Manhole Lid C-levations and the elevation or lhe.First Floor
-----u'i
.? _ 2.19
3
)rdinanceg-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
The District'reseives the right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible at all times.-,Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met. Connection to the sanitary sewer is now permitted.
C tRWn
>igning below, I attest that I am familiar with ^the-0 tricfsspecilications and agree to accept. responsibility for allwork done under this permit.
ilder / Owner,Signature./ / Phone Number 31)- 71Y 3557
Printed Name ' 4 a h14l7rN5 - Aljlih??
Approv 8 z Permit Date 81 2 412 0 0 7
Feltner, Ouedorof Admmatratron BCusfomer Sernce
ad 7126107 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice provi
sewer is within 300-feet for Hamilton County or 100 feet for Boone County of the, property line. Only one buildin
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation orother "storm water, drains shall be interconnected to the sewer lateral installed and'connecte
the District's sanitary sewer.
3. The ezi"sting,sewer line from the building to the septic tank may only be used if it is located under a.building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owr
shall bear the cost of all testing. The District inspector must ,be onsite for the duration of the air test.
4. The owner or contractor shall notify the District -prior to covering the installed lateral so that the District can rr
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is.n
site for scheduled inspection, ortifails to cancel inspection, an additional fee. of $100.00 will be due. This must be
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenan
private sewage disposal (septic) systems, The County Ordinance provides in part that, upon connection to a pr
sewer; a septic tank '...shall be.abandoned (pumped clean) and filled completely with earthen material or stone
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and t
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE' SDR.35 or SDR26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM.D2241, SIX INCH PIPE
RESTRAINED JOINT PVC 'PIPE (DIRECTIONAL DRILL): Yelomine"SRD 21,
ASTM.D2241, SIX INCH.PIPE (use only per approval of the District Engineer)
GASKETED JOINTS. ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON' MECHANICAL COUPLING WITH PROPER FITTINGS
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill mate
be placed from 6_inches below to 12 inches above the pipe. The trench should be a,minimum of 18 inches wide
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water.wells unless PVC pressure grade pipe is used n
SDR 21 and ASTM D2241. Any, proposed' installation. requiring pressure pipe shall be reviewed and accepted
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10: Laterals shall terminate within 3, feet of the building unless the conditions in item #3 above are met. No glr
shall be installed outside three feet of building foundation walls.
11.. Additional information on District standards and specifications maybe obtained from the District's office du
business hours of 8''00a.m. to 4:30.p.m. Monday through Friday: All District standards can be located on our wi
at http://www.etRvd.org/.
Clay TownshipRegional_Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent, shall notbe pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top.of the I
The District inspector will verify placement of the wire After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging
Revise
&A" Group
a"c! Sur-veyor-s
West Carmel Drive, Carmel, IN 46032
317.844.3333 F 317.844.3383
www.seagrouplic.com
00.0 PROPOSED GRADE PER PLAN
GROUND WATER FLOW
- SANITARY SEWER LINE
-m m - STORM SEWER LINE
-? ?- WATER LINE
.------------- EASEMENT LINE
- - BUILDING SETBACK LINE
IS PLOT PLAN WAS
EPARED BASED ON
7ORMATION TAKEN FROM
CORD PLATS, SUBDIVISION
ANS, RECORD DRAWINGS
D PLANS PROVIDED BY
ENT. IT IS THE
SPONSIBILITY OF THE
NTRACTOR TO VERIFY SITE
NDITIONS PRIOR TO
NSTRUCTION AND NOTIFY
E S E A GROUP LLC OF
Y DISCREPANCIES.
:ATION OF UTILITY
'ERALS ON PLOT PLAN
GENERAL LOCATIONS
t PLAN AND SHOULD BE
FIED IN THE FIELD.
E:
LDER TO ENSURE POSITIVE
W AWAY FROM
UCTURE.
'
Q p
/
GARAGE tel.\\ ??5 \?
\ FFE=90&0
/ ?ca:c
0R6t \ \ /
GARAGE
\ FFE=903.0 /
MINIMUM SETBACKS
MIN SIDE YARD = 5 0 Feel
MIN REAR YARD = 30 Feet
Ayy = 15 Feet between structures
NOTE:
BUILDER TO MAINTAIN A 10'
SEPERATION BETWEEN WATER
AND SANITARY LATERALS.
NOTE:
SUMP TO BE PLACED BY
BUILDER AS NEEDED.
i 3` 91
PROPOSED
FRM a MSY
RESIDENCE
FFE=909.0
8SMT
FFE=899.0
so
00 • / ^6
/
CLCQ // ?
101
1X?b?'
ly Description:
ember 9 in Saddlebrook at Shelbourne, Section One, an Addition in Hamilton
'y, Indiana, as per plat thereof recorded as Instrument Number 200500077945
in the Office of the Recorder of Hamilton County, Indiana.
PLOT PLAN
May 1, 2007
Prepared For:
Jones Building Group
Drawn by DJR Residence
Revised: June 22, 2007 1 3328 Homestretch Drive
LOT# 9
15,000.0 S.F.
gyp? Q?p?
4
. AI G rR%5??
•??OISTE'jiE;OA
No.
€ LS20200083
STATE OF
SU
/
c
O \
O \
/ \\ 905.0 \\
,SqM; CITY OF CARMEL / CLAY TOWNSHIP
?WATER / SEWER PERMIT / RECEIPT
2CEL ID #: ZSBS9
r & SUBDIVISION: 9 SADDLEBROOK AT SHELBORNE
DRESS OF CONSTRUCTION: 3328 HOMESTRETCH DR CARMEL, IN 46032
fMENT RECEIVED FROM:
ne: JONES BUILDING GROUP
CHECK #: 15537
:AVATOR INFORMATION:
ne: SANITARY MANAGEMENT & ENG. CO.
#: (317) 577-1150 Fax M Email:
et Address: 11901 LAKESIDE DR. FISHERS, IN 46038
d Expiration:
'.MIT TYPE: USEWRWATR ; SEWERNVATER PERMIT
cial Notes/Conditions:
Permit #: 07080218
Date: 08/2712007
T 9 SADDLEBROOK AT SHELBOURNE. WATER.
O NOTES'
building & Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting
M specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
be installed in accordance with ASTM 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
ict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
?(a), and sections P3008-1 and 2 of the International Residential Code. All building sewer shall be 6" diameter.
t tallations shall be "oven trench" inspected and approved by the Carmel Sewer Department before any backfilling is done. Non-
diance may result in digging up the sewer installation and/or denial of future sewer permits and.'or denial of water connections -
toting or foundation drains or other Sources of ground water or storm water shall be permitted to enter the public sewer.
r inspection- should be requested at (317) 571-2645 one to four hours in advance.
spcctions or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
wrs or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY EN'GINEER'S OFFICE. If any street
to cut. a senwate street cut nerrnit shall he obtained.
CANT NAME: DAVID HATCHER
ENT RECEIVED BY;
00
CITY OF CARMEL
i of 1
PERMIT RECEIPT
OPERATOR: twedding
COPY # : 1
Sec:32 Twp:18 Rng:3 Sub:SBS Blk:i Lot:9
PARCEL ID ........: ZSBS9
DATE ISSUED.......: 08/27/2007
RECEIPT #.........: 26121
REFERENCE ID # ...: 07080218
SITE ADDRESS .....: 3328 HOMESTRETCH DR
SUBDIVISION ......: SADDL•EBROOK AT SHELBOPNE
CITY ............. : CARMEL
IMPACT AREA ......
OWNER ............ : JUNES BUILDING GROUP
ADDRESS .......... : P.O. BOX 3741
CITY/STATE/ZIP ... : CARMEL, IN 46032
RECEIVED FROM .... : JONES BUILDING GROUP
CONTRACTOR ....... . LIC # XSANIMAN
COMPANY .......... : SANITARY MANAGEMENT & ENG. CO.
ADDRESS .......... : 11901 LAKESIDE DR.
CITY/STATE/ZIP ... . FISHERS, IN 46038
TELEPHONE ........ : (317) 577-1150
ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC
-
-
----
=ONN ------------- --------
FLAT RATE 1. -- ---------- ----------
00 1310.00 0.00 ------
-
-
1310.00
CAP FLAT FATE 1. 00 86.00 0.00 86.00
------
-
-
HERM IT ---------- ----------
1396.00 0.00 -
-
1396.00
OF PAYMENT AMOUNT NUMBER
---------- ------------ ------------------
1396.00 15537
=EIPT 1396.00
NEW SAL
0.00
0.00
0.00