HomeMy WebLinkAbout07090082 Pool Plans.I
n M?
.e h
J
3 ?
? e
J ?
I
I
I
Npf p?j51J 0 a°v . .pair'
d\ 00°o 1- 00 u
6NO?yo?`?y? ? ? ? L
O h ?
J ? 2
a I :
g
ti ,V
?a ,M I
E ?
I
d
-.a .a e J
n a
4
J
a
a
ci
GENERAL NOTES
1. Install a G; CI as requlred by the National Electric Code
and the Canadian Electrical Coce:
2. All wiring should be done by a Ilcepsed electrical con-
tractor in accordance wltn local electrical codes and as
required by the National Electric Code or the Canadian
Electrical Code, is "applicable.
i. See Table I for recommended pool lighting levels. See
Table II, Page 4, for light niche bulb anc cord specifica-
licns.
J CAUTION Risk of burns: Lights over 1•DO`N.
ommenciad for spa Installation.
Table I: Typical Lighting Reeuh emen's
Allowance of
Watts/Sq. Foot
Type a Pool D,- Pool Area -
Small Residential Pods
(Less than 80I7 sq. h. (75 sq, m,)) 1/2 to 1
Large Public Pods 1 to 1.1/2
Diving pools (Less.than 12 h. (.151.1) deep) 1.1/2 to 2
Diving Pocls (12 :0 2G ft. 13.65 to 6M.) deep) 2 tai
Competition Tools. ;' - - 2 s0 3--
,are 900 wall liihl at deep end of wol Is recommended
•• .:Of compelllion xals; - - -
1- make sure Thal the starVYlnish ends of lanes are well Ilghted.
L vever install lights In end walls a1 end of s?rlmrr.ing lanes, :Howe-et,
ii shoo course racing is provided across the width of a 50 never
nurse, light fixtures may be installed ben eer lanes fencer racir:g
line<.) or. a separate switch.:
JUNCTION BOX
Locate Min. 4V (127a mn) Behind
Pool Wall and Min a' (249 mm?
Above Up of Cpping
(around ' \ W? From
'? ( P. Fr Supply
a• aAln\
(2CJ mm) .
adult from Nlohe
Lip or Coping
ElevaJcn
Figure junalgn BOX, Part 105730.0021
-"1 in (Sa l lsunl - - .L/' (l0.G5 -)
It Ye' or VWA n•m)
(271 T') 0c, 1
a
6um'?1 Crt ly,
G: ovnc
mr.:)
-?"'wY•'?f wl'I, \ Hen-u, Wil:
Faes Min; ?omxsnd tliht Cord
Figure 2: Niche Dime msions
Jur.cdon I .
Coping
Tib ? Bo-
6aok '\I ? j
'^.,.
water.
/
Level o
J, u
'
1P• h" p "
Tc J•:noJcn
mm) Q
M4
' I y/•(19.05 ni
\
0; 1 ;aa.a n,
- bl A?.prv?e:
S.S. '_Ipht Wl n. -
Nor Stria-a017-LG'(t 9.J5 m
. . No. SC44-:017.1'125.0 nml
C Q
. II ,.I Underaaler LIC;.t
r •'
0- Aptprovsc
r 4 csmcrd Clam;
' 4• min,
O.'. (t C7 n:r.)
a-r1 Bus (e.W. )
Figure 3; Niche Installation In Gunite Pool
- any person from contacting it, install the fiz,cre in or o
pool wall with the top of the lens opening ai least " d
(.5M) oelow the normal water level of the cool.
Lights and niches shall be used In fresh water pools cr
• The lens Is heat resistant, glass' and focuses the lignt be
In a 301 horizontal arc, with 1.5• downward deflectior
and Is sealed by a molded one-piece wrap-arcu-.d me(
prene gasket. A stainless steel face ring with 1C movnl