Loading...
HomeMy WebLinkAbout07090049 Site PlanThe 3ebaeider Corporation 9901 Due Armae Hiatorte rat tlerriaaa bad; mnpolls Indiana 16215-110M 917-625-7100 917-528-72W FAX This Plot Plan Prepared For MA Homes Lot # 72, containing10,399 S.F.t, in Heather Knall Section 0 2 Instrument # 2006-00004470 PC 4 Slide 13 Clay Township, Hamilton County SEC 205 T18K RODE 2647 PARAMOUNT CIRCLE ( 50' R/W) Westfield, IN 46074 Prepared Date:09/06/07: By. KAG Community Restrictions: Side Yard = S min. Aggregate = 6' B.H. - -- Zoning - St M/I HOMES Pad Grade = 917.7 per plan Pad Grade + 0.2' = Garage FFE (917.9 ) Garage FFE + 0_5' = Residential FFE (918.4 ) Residential FFE - 9.0' = Basement FFE (909.4 Driveway Slope = 3.1% Note : The garage finished floor elevation is 1.1' above the nab at the drive, per plan. GROUND COVER CALCULATIONS: Drive = 661 SFt Public Walk =319 SFi Private Walk =N/A SF3 Seeding =5,247 SFt Sod =255 SYt, from front of residence. Note: Builder to ensure positive drainage away from structure(s). MH/722 TC=91&39 PER RECORD DRAWING FLOOD HAZARD STATEMENT CERTIFICATION Note: ?? This drawing is based on construction plans or record drawing and is not based upon a Field survey. The Schneider Corporal 3111-11114111 Landampe Arehilectum does not warrant the accuracy or sufficiency of this informal GIs - LS Contractors should verify existing conditions prior to any Galatea construction. Any discrepancy found an this drawing should b reported to The Schneider Corporation immediately, foiling to so results in the contractors assumption of all liability. Plot Plan Legend ® Proposed Grades 000.0 Existing Grades ?000.0? Contour Grade * Approx. Lateral Location a - Sanitary Sewer Lines per- Storm Sewer Lines - v - Water Service Lines - - - - - - Sub-Surface Drain Lines ® Manhole (Sanitary or Storm) ® Beehive Inlet (Storm) ® Curb Inlet (Storm) D End Section (Storm) A6 Fire Hydrant -Flow Line of scale - Building Line (BL / BSL) - - - - - - - Easement Line Snnitarv Top of Casting Information Upstream Manhole, TC=917.13 Downstream Manhole, TC=918.39 per record dreg. CONC DRIVE - Ma' 915.7 915.7 46.3' 915.7 3' - - ? m? 15' R.D.E. - - - u S4 ?y c ° 80.00'T - C. A. #7 I I 1' 36.3' 915. REVISION ill FLIPPED GARAGE HANDING V607,0079915 09113107 - KAG VAR. D.U.&S.S.E.& Z L. M. A. E.&P.I.E. E. 4; 7 ??E ° A.tOQE This drawing is not intended to be represented as a retrocement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown an this plat plan is sub)ect to map scale uncertainty and to any other uncertainly in location or elevation on the referenced flood insurance rote map (FIRM). ALL of the within described land DOES NOT LIE within that special flood hazard zone 'A', as said land plots by scale on Community Map Panel if 18057C0205F of the flood insurance rote maps (FIRM) for Hamilton County, Indiana, Dated May 19, 1981. Note The cmtroctor is to maintain o minimum distance of ten feet (10') between the smilary sewer and water lime laterals. 30.0' B-B I ROLL CORE P Note: The basernent elevation, depicted harem, has been detemknd and based an the pad grades aM/a contours taken ham the construction plan for this sAtdivisnm Unless stated, no nfmnotion about fluduati f; water table, sol conditim% a soi types has been provided or stated an said plans, This lot is located near a body of water. Lot a sd conditions may require that the basement hoar demotion be held 2 loot above normal pad elevation. Site invest/ onion may be needed if wales is encountered during the excavation process a if other know water elevation a sacs conditions we present. Investigation and my remedial procedures is at the discretion of the builder to determine ad take appropriate steps of action. If my ground water is am Imed during excavation the buider is encouraged to cmtoct The Sdmeider Corporation to discuss passible caries of action. NOTE: BY BUILDER AS NEEDED. LOT # 72 VB07.0079713 THE UPSTREAM MH TC ELEVATION SHALL BE NO LESS THAN 1'-0' BELOW RESIDENTIAL F.F.E. 0 Assumed North Scale : 1' = 30' CIRCLE 6.68 5' WAD( Rio I 16' 80.00' %. 26.0 CONC r DRIVE 20' D.U.&S.S.E. l _Oo. P! 203x' - 8 o 25' B.L. 8 THREE CAR 10.3} GARAGE 8 Portal 11.2' JaOV - ' BASEMENT _ 17.00 PUMP BRODERl A FRM&MSY RESIDENCE N PER "Pwl 5' WALK I M H.72328.4c_ ?4 T PER PER RECD RECORD DWG 2 0' D.U.&S.S.? 25' B.L. [ - - F 0 RCH F P 17. 10 I SUMP PUMP I?j I e ?9.Y l s' I I I I 5.1' T I 8 DECK N 'B TYPICAL SWALE SECTION NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REM YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.