HomeMy WebLinkAbout07100012 Sewer/Water Permit/sCITY OF CARMEL
Item. 1 of 1
PERMIT RECEIPT
OPERATOR:
COPY # .
plux
1 f
1 Sec:20 Twp:18 Rng:03 Sub:TRH Blk: Lot:5
PARCEL ID ........: ZTRH5
DATE ISSUED.......: 10/03/2007
RECEIPT #.........: 26419
REFERENCE ID # ...: 07100008
SITE ADDRESS .....: 14218 BRANDT LN
SUBDIVISION ......: TRAILS AT HAYDEN RUN, THE
CITY .............: WESTFIELD
IMPACT AREA ......
OWNER ......... ... : ARBOR HOMES, LLC
ADDRESS ....... ... : 6666 E. 75TH ST., {#400
CITY/STATE/ZIP ... : INDIANAPOLIS, IN 46250
RECEIVED FROM . ... : ARBOR HOMES, LLC
CONTRACTOR .... ... : LIC # XJDHCON
COMPANY ....... ... : JDH CONTRACTING
ADDRESS ....... ... : 8109 NETWORK DR.
CITY/STATE/ZIP ... : PLAINFIELD, IN 46 168
TELEPHONE ..... ... : (317) 839-0520
FEE ID NIT QUANTITY AMOUNT PD-TO -DT
- - THIS REC
--------- NEW BAL
- ---
-----
---------- -------------
USFWATCONN FLAT RATE ---
1. -- ----- ------
-----
00 1310.00 ---
0.00
1310.00
0.00
UWATERTAP FLAT RATE 1. 00 86.00 0.00
- 86.00
--------- 0.00
----------
TOTAL PERMIT ---------- ------
1396.00 ----
0.00 1396.00 0.00
METHOD OF PAYMENT AMOUNT NUMBER
------------
--
-
----------------- ---------
CHECK 1396 ---
.00 -
--
07100008
TOTAL RECEIPT 1396 .00
CITY OF CARMEL / CLAY TOWNSHIP
J. F4 i
WATER / SEWER PERMIT / RECEIPT
PARCEL ID #: ZTRH5
LOT & SUBDIVISION: 5 TRAILS AT HAYDEN RUN, THE
ADDRESS OF CONSTRUCTION: 14218 BRANDT LN WESTFIELD, IN 46074
PAYMENT RECEIVED FROM:
Name: ARBOR HOMES, LLC
CHECK #: 07100008
EXCAVATOR INFORMATION:
Name: JDH CONTRACTING
Ph. #: (317) 839-0520 Fax M Email:
Street Address: 8109 NETWORK DR. PLAINFIELD, IN 46168
Bond Expiration:
PERMIT TYPE: USEWRWATR ; SEWERNVATER PERMIT
Permit #: 07100008
Date: 10/0312007
Notesluonanions:
LOT 5 THE TRAILS @ HAYDEN RUN, WATER PERMIT
NO NOTES "
The building & Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting',
.ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTNI 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.1 and 2 of the International Residential Code. All building sewers shall be B' diameter.
All installations shall be "open trench" insuected and approved by the Carmel Sewer Department before any backbiting is done. Non-
compliance may result in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public server.
Sewer inspections should be requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street
most he cur_ a separate street cm. nermit shall be. obtained.
APPLICANT NAME: JOCELYN ZELLERS
PAYMENT RECEIVED BY-,.?
FEES:
$1,396.00
-- II k
Regional Waste District
Residential SANITARY SEWER,PERMIT
00609 INDIVIDUAL LOT/ EXISTING BUILDINGS `
Permit Type Final
Subdivision Trails_at Ha_d_e_n_ -Run
Section Number 1
Lift Station
---------- 23 126th Street station
-------- --------------- --
Treatment Plant
------- MIX
----------
Builder
- ------------ Arbor Homes
-----------------------
___
Phone Number
------- ;
317-842-1075
----------------- -- -----
Parcel Acreage
------------ ------- ------------
EDU in Gallons 310
Lot Number 5
Address Number -14218
Street Brandt Ln
City Westfield
------------------------------- ;------
Zip Code 46074
------------------------------------
County Hamilton
------------------------------------
Local Sewer Charge
----------------- ------
Plan Review and Inspection
------------------
Application Fee $100.00
EDU Fee $1,650.00
------------------------------------
Interceptor Fee
Invoice Number Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
.'open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the. District's sanitary sewer system. The.
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit
Inspections by the District are MANDATORY and shall be arranged bycontacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing six months after connection has been made c ;,r
when water is connected, whichever comes first.
The building has: USMH THR-806 THR-805 DSMH
Grease Trap No Slab Foundation No Lid Elevation 920.88 It 920.02 ff
_--__- _--_-_ -
- -_-- --------------- --------.--r
Grit Interceptor
--- No
----- Crawl Space
----- No
----- First Floor Elevation 921.90 ft
---------- 921.90 tt?
---------
Grinder Station
No
Basement -
Yes
Basement-Elevation 911.90 ft 1
911:90 ft1
Calculation is based od both Manhole Lid Elevations and the elevation of the.First Floor 1.02 1_08
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
{ The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
shall remain accessible at all times. Buried manholes will be. corrected by the Developer/Owner
Conditional. Permit Terms: -•
All conditions have been met. Connection to the sanitary sewer is now.permitted.
By signing below,-Fattest that lam famili wthe ' trio's' cifications and. agree to accept responsibility for all work done under
Builder / Owner Signature L Phone Number -?)JLA
Printed Name _Q ??'P?
Permit Date 10/212007
Revised 7!26107 Permit is.valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the, District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3; The existing sewer line from the building to the septic tank,may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the.District's sewer use ordinance. Such notification.shall be made 24 hours
prior to the need for the inspection. If the.inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or failsto cancel'inspection, an additional fee'of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "... shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,.
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO femco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
B. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed.and accepted by the
District and the District's engineer prior to installation:
9. Where a transition is made between SDR' 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of B:OOa.m. to'4:30 p.m.. Monday through Friday: All District standards can be located on our web site
at http://www.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out-into ttie.sani1ary seweF system
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours priorto time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig; IUPPS 1-800-382-5544, 48 hours,prior to digging.
Revised 7124/07
She 8chneldr Corporation
8801 DUB Arsine
Hie= Port Herrltoa
7adlypepaH" hidiena 462Le-10.97
917-826-7100
817-826-720) VAX
This Plot Plan Prepared Far. Arbor Homes
Lot # 5 , containing 14,406 S.F.t, in
The Trails at Hayden- Run Sec. 1
INSTR. # 200500069468
Clay Twp, Hamilton County
Sec 20, T29N, R3E
14218 BRANDT LANE (50'R/W)
Westfield, IN 46074
Prepared Date: 08/08/07: By. KAG
Community Restrictions
Side Yard =3' min.
Rear. Yard = N/A
Aggregate = (B.H.)
ARBOR HOMES
Pod Grade = 920.4 per celc.
Pad Grade + 1.0' = Garage FFE (921.4 )
Garage FFE + 0.5' = Residential FIFE (921.9 )
Residential FIFE - 10.0 = Basement FFE (911.9 )
Driveway Slope = 5.1%
Note : The garage finished floor elevation
Is 2.0' above the curb at the drive, per
plan.
GROUND COVER CALCULATIONS:
Drive = 928 SFt
Public Welke =33 SFt
Private Walk =77 SFt
Seeding = 8,289SF--
Sod = 3,056 SFf ,
even with the rear of house.
Note:
linvpearbIg this drawing is based an construction plans or record drawings,
Sur-Thas and is not based upon a field survey. The Schneider Corporation
landmape Architactar°
Gig - S does not warrant the accuracy or sufficiency of this Information.
Gig -
or Contractors should verify edsting conditions prior to. any
construction. Any discrepancy found on this drawing,should
be reported to The Schneider Corporation immediately, failing
to do so results In the contraators assumption of all liability.
Plot Plan Legend
FO-0-0,7
000.0 Proposed Grades
Ezdstkig Grades Note:
The basement elevation, depicted hrem, has been determined end based or
-000
0 Centaur Grade the pod grades and/or contours taken from the cenatructon plans far this
i
.
* Approx. Lateral Location subdlvscn. Unless stated, no information about fluctuat
ng water table, sod
6
8 Sanitary Sewer lines conddons, or sol types has been provided or stated an said plans This lot
-
? Storm Sewer Lines
e
er is located near a body of water...ot or sol conditions may require that the
-
v
- w
Lines
Water Service basement. flan elmilon be held 2 foot above normal pod elevation. Site
Investigation may be needed 0 water is encountered during the sxcavotir
- - -
- SubSurface Drain lines process or If other known water elevation or sots conditions are present.
• Manhole (Sanitary r Stone) Investigation and any remedial procedures is at the discretion of the builder
® Beehive Inlet (Stone) to determine and take appropriate steps of action. It myngrcund water is
® Curb Inlet (Storm) encountered during excavation the bulder Is encouraged to contact The
D End Section (Storm) Schneider Corporation to disam possible course of action.
Fire Hydrant
- _ • _ - - > • - Flow Line of swale NOTE:
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC=920.68
Downstream Manhole, TC=920.02
per record drawing.
Note:
fie contractor Is to maintain a
minimum distance of ten feet (10?
between the sonitry sewer and water
line laterals
Note: Buidr to ensure positive
drainage away 'van structure(s).
15' D.U.&S.E
SUMP PUMP(S) TO BE PLACED
BY BUILDER AS NEEDED.
nt.
M,KW
70=920.66
PER RECORD
LOT # 5
VB # 07.0078336
0
o?o
Assumed North
Scale : 1• = 30'
z
5
a
v
0
m
n
w=elLAN
I IPER PLAN I
, I -
I r-
16 a I
-------- -15'D. U.&S.E-L 28.1'0
I I 34.33' 38.7 -
a e ml
II
'
_
Y,
Z ?I
70.0
I 7.00
S 2
m
I
1 g g
200
' 7. 2.00 ?
69.0
I
F q
?r
? d
00 II
i ' 3
1'
1.6 O
N 0.
QL.;k I I
4 rwy
/
1
M
1
h
I 'r-------------------- J J ^
1
ti¢
I
W i.l
Q
Note:
Per Cormel zoning ordinance 26.1.1 : The residential
district remits height to twenty-fire feet (25?1, however
a dwelling may be Increased in height to thirty-five
feet (35') provided the side and rear yards are increased
an additional one foot (1) far each one foot (1') the
structure exceeds the first twenty-five feet (25) in
height
A .
4
OPE
4'1
TYPICAL SWALE SECTION
This drawing is not intended to be represented as a retracement or
oricinci boundary survey, a route survey, or a Surveyor Location Report.
Flood Hazard Statement: The cemroey of any flood hazard data shown on this report
is subject to map scale uncertainty and to any other uncertanty in location or
elevation an the referenced flood insurance rate map. ALL of the within described land
DOES NOT LIE within that special flood hazard zone A as said land plots by scale on
flood insurance rote map 118057OD205F for Clty of Carmel, Indiana (maps doled
February 19, 2003).
REASON E1
ADDED 3RD CAR BAY
V307.0080695
09/27/07 - KAG
W IN >
Z I
5 p' Q I
ER PLAN J I
I
I
o
qGG "i
S T
Q I
? IC
r
of I
?- 1
1
D•10.0? 1? c
16 300'
wya B-B
1
3
FLOOD HAZARD STATEMENT
CERTIFICATION
N0.
S0303
STATE OF
!.? •'•rA'DIANP'?.tJ
yD"•..S URV??