Loading...
HomeMy WebLinkAbout07100006 Site Plan The Schneider corporation b&-ta t 6901 otb beam 9111-gdnY Fatoric Part Harrison landscape Arebiteckae Indianapolis, Indian. 461 GIs •119 917-825-7100 GedoO e 917-626-7200 PAY ?p Plot Plan Legend This Plot Plan Prepared For. SUrerthome Homes ® Proposed Grades Lot # 43 , containing 16,783 S.F.t, in 000.0 Existing Grades Aberdeen Bend SubdhMsion * a * Contour Grade Approx. Lateral Location Section # 1 - a- Sanitary Sewer Lines 1NSTR. # 200500066134 x- - v - Storm Sewer Unes Water Service Lines Book # 3, Page 1739 - - - - - - - Sub-Surface Drain Lines Hari ton County, Gay Township ® Manhole (Sanitary or Storm) 12791 TRUMAN COURT (50? R/N) ® ® Beehive Inlet (Storm) Curb Inlet (Storm) Carmel, IN 46032 D End Section (Storm) Prepared Date: 09/21/07 : By. KAG J0. Fire Hldrant - _ • _ - • _ • - Flow Line of swole Community Restrictions: Side Yard = N/A Rear Yard = 25' Aggregate = 30' Zoning = Sl Slverthome Homes Pad Grade - 913.0 per plan Pad Grade + 1.0' = Garage FE (914.0 ) Garage FFE + 0.5 = Residential FFE (914.5 ) Residential FFE -10.07 = Basement FIFE (904.5 ) Driveway Slue = 6.3% Note : The garage finished floor elevation is 2.5' above the curb at the drive, per plan. Ground Cover Calculations: Drive =1,300SFt Public Walk =464 SFf Private Walk =195 SFt Seeding =8,136 SFt Sod = 5,004 SF: , to the rear of home. O 1 26.0' `? 38. 1"<,I 1 t , ABE 112 TC=913.90 PER PLAN 26.0' / 36.0' 15,0\ ? N\ V (^ 30.0' 6--8 N r- Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC=913.90 Downstream Manhole, TC=911.20 per plan. Note: The contractor Is to maintain a minimum distance of ten feel (10') between the sanitary sewer and water line laterals. Note: Builder to ensure positive drainage away from structure(s). Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately, failing to do so results in the contractors assumption of all liability. Note: The basement deratlen, depicted hereon, has been determined and based an the pad grades and/a eentoura taken from the construction plena fa this subdivision, unless slated, no Information about fluctuating water tables, sell conditions, a soil types has been provided or stated on sold plans This lot Is located near a body of water. Lot or sal oonddione may require that the basement floc desatim be had 2 foot above normd pod eievatiaa Site Investigation may be needed N water Is encountered during the excavation process or N other known water elea tion an soar conditions ore present Investigation and any remold procedures is at the dlsaation of the builder to determine and tan appropriate steps of action. If any ground water is encountered during excavation the 6urdr is encouraged to contact The Schneider corporation to discuss possible caun of acllm. NOTE: SUMP (S NEEDED. PLACED BY BUILDER A LOT# 43 VB07.0080426 o?o Assumed North Scale : 1' = 30' 186.58' 13.0' I 40.67' 8 Y N S?C ??? ? O 11.33' 3 15.67' a ?t4 3° .00 g 25.0' Si 30.0' h 5.0' sD 1 156.06' W o x N 75.7 65.1' 00 0 0 FLOOD HAZARD STATEMENT CERTIFICATION L S0303 This drawing is not intended to be represented as a retracement or original boundary survey, c route survey, or a Surveyor Location Report. FLOOD HAZARD STATEMENT The accuracy of any flood hazard data shown on this plot plan is subject to map scale uncertainty and to any other uncertainty In location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT UE within that special flood hazard zone A as said land plots by scole on community-pond / 180080 0205F of the flood Insurance rate maps for Carmel, IN (maps dated Feb. 19, 2003). STATE OF