Loading...
HomeMy WebLinkAbout07100004 Site PlanNote The Seluxdda Corporation byfaeenla This drawing is based on construction plans or record drawings, 6901 Otis ATeaue sozreyina and is not based upon a field survey. The Schneider Corporation Historic Fort Harrison landscape Ambitecture does not warrant the accuracy or sufRclency of this infonnatior. Indianapolis, indite.. 48216-1037 317 826 7100 GIB •179 Ge°D Contractors should verify existing conditions prior to any - - 917-826-7200 PdY U construction. Any discrepancy found on this drawing should This Plot Plan Prepared For: Arbor Homes Lot # 46 , containing 12,599 S.F.=, in The Trails at Hayden Run Sec. 1 INSTR. #-200500069468 Clay Twp, Hamilton County Sec 20, T29N, R3E 14240 LANGHAM DRIVE (50'R/W) Westfield, IN 46074 Prepared Date: 09/21/07 : By. KAG Community Restrictions: Side Yard =3' min. Recr Yard = N/A Aggregate = 6 (6.H.) ARBOR HOMES Pad Grade = 920.3 per plan Pad Grade + 1.0' = Garage FFE (921.3 ) Garage FFE + 0.5' = Residential FFE (921.8 ) Residential FE - 9.0' = Basement FIFE (912.8 ) Driveway Slope = 5.0% Note : The garage finished floor elevation is 1.9' above the curb at the drive, per plan. GROUND COVER CALCULATIONS: Drive = 648 SFf Public Walk =369 SFt Private Walk =75 SFd: Seeding = 6,649SF± Sod = 3,631 SFt , even with the rear of house. T0=919.00 PER PLAN 15' O.U.&S.E 4 W 4j u on ? rr j J O W ri ?? rn Z II II d 9E C z°o be reported to The Schneider Corporation immediately, failing to do so results in the contractors assumption of all Iicb9fty. Plot Plan Legend Note: Proposed Grades The basement elevation, depicted hereon, has bem determined and based on ODO.0 Existing Andes the pad grades and/or ombeurs taken from the construction Florist far this -000.0 Contour Grade subdivision. Unless stated, no Information about.fluctuating water tables, m0 * Approx. Lateral Location conditions, or sod types has been provided or stated m mid plans. This lot 8- Sanitary Sewer Lines is located new a body of water. Lot or sot conditions may requite that the BT - Storm Sewer lines basement floor elevatim be held 2 foot above normal pod elevation. Site - v - Water Service Linee in,eslig6on may be needed if water Is encountered during the excavation - - - - - - - Sub-Surface Drain Lines groom or H other renown water elevation or mOs conditions are present. 10 Manhole (Sanitary or Storm) Imesllgal'wn and any remedial procedures Is at the discretion of the buidr ® Beehive Inlet (Storm) to determine and take appropriate steps of action. If my grand votr is ® Curb Inlet (Storm) encountered during excavation the bulder_Is encouraged to contact the D End Section (Storm) Schneider Corporation to discuss passible courses of actim. A. Fire Hydrant NOTE: Flaw Une of swde Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC=920.59 Downstream Manhole, TC=920.05 per record drawing. Note: The contactor Is to maintain a minimum distance of ten feet (10) between the sanitry sewer and water line laterals. Note: Builder to ensure positive drainage away from structure(s). M.F.P.G.=920.0 (MIOUM FLOW PROTECTION GRADE) 15' D.U.&S.E W °I o rn °' I 66.7 74.7 FLOOD HAZARD STATEMENT CERTIFICATION L, L S0303 STATE OF SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. LOT # 46 AA W? V v V ' I ' B-B VB # 07.0080316 [I n-Fy??1{ o?o `r Assumed North Scale : 1' = 30' M.H'009 TC=92059 PER RE ORA'w1NG II I I ? rn 75 &o' - 11 J -_- I I A anI m 34.33' w ` ' A [d l ? I o us I PER PLAN n n z6.r- , o za I m i 00 I • I gg r9 O A C5 I rn q 37.3S 12N I F.P. I 380 ? I 18 0 I . 920.3 919.8 i O VACATION FOR THE STULTZ & ALMOND LEGAL EASEMENT DATED JANUARY 9TH, 2006. This drawing is no( intended to be represented as a retrccement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement The =racy of any flood hazard data shown on this repot. Is mb)mt to map Kole uncertainty and to any other uncertainty in location or elevation on the referenced flood Insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as mid land plots by scale an flood Insurance rate map it 18D57CD205F for qty of Cannel, Indiana (maps dated February 19, 2003). u? I I I - - A W i TC=919.70 ? PER PLAN 919.4 I I u: O I = I O I O I I I es ?R I M.H.?Ofi iC-920.05 PER RECORD DRAYANG z 3 4: P ? t ¢ppE TYPICAL SWALE SECTION Note: Per Cannel zoning orbanee 25.1.1 : The residential district limits height to twenty-five fat (25), however a dwelling may be increased in height to thIrty-five feet (35) provided the side and rear yards are increased on additional one foot (i) far each one foot (1) the structure exceeds the first twenty-five fat', (25') in height.