HomeMy WebLinkAbout07090129 Sewer/Water Permit/sCITY OF CARMEL
Item 1 cf 1 PERMIT RECEIPT OPERATOR: plux
COPY # : 1 rol%
Sec:28 Two:18 Rng:03 Sub:STP B10 2B Lct:208
PARCEL ID ........: 1709290018038000
DATE ISSUED.......: 09/26/2007
RECEIPT #••.......: 26349
REFERENCE ID # ...: 07090125
SITE ADDRESS .....: 13455 CUPPERTINO LN
SUBDIVISION ......: STANFORD PARK
CITY .............: WESTFIELD
IMPACT AREA ......
OWNER ............: RYLAND HOMES
ADDRESS ..........: 9025 N. RIVER RD.
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46240
RECEIVED FROM ....: RYLAND HOMES
CONTRACTOR .......: LIC # XA-1SUP
COMPANY ..........: A-1 SUPERIOR EXCA VATING
ADDRESS ..........: 3143 ROSEWAY DR
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46226
TELEPHONE ........: (317) S98-0767
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT
- THIS REC
-- NEW SAL
-----
-----
---------- ------------- ----------
USFWATCONN FLAT RATE i.00 ---------- -----
1310.00 -----
0.00 1310.00 -
0.00
UWATERTAP FLAT RATE 1.00 86.00 0.00
- - 86.00
--------- 0.00
---
TOTAL PERMIT ---------- -----
1396.00 ----
0.00 1396.00 0.00
METHOD OF PAYMENT AMOUNT NUMBER
----------------
--
----------------- ------------
CHECK 1396.00 13723
TOTAL RECEIPT 1396.00
r` Permit
°, . CITY OF CARMEL /CLAY TOWNSHIP #: 07090125
f WATER / SEWER PERMIT / RECEIPT Date: 09/26/2007
?h?IpMF
PARCEL ID M 1709290018038000
LOT & SUBDIVISION: 208 STANFORD PARK
ADDRESS OF CONSTRUCTION: 13455 CUPPERTINO LN WESTFIELD. IN 46074
PAYMENT RECEIVED FROM:
Name: RYLAND HOMES
CHECK M 13723
EXCAVATOR INFORMATION:
Name: A-1 SUPERIOR EXCAVATING
Ph. #: (317) 898-0767 Fax M Email:
Street Address: 3143 ROSEWAY DR INDIANAPOLIS, IN 46226
Bond Expiration:
PERMIT TYPE: USEWRWATR ; SEWERNVATER PERMIT
Special Notes/Conditions:
LOT 253 STANFORD PARK, WATER PERMIT
' NO NOTES'
The building & Sewer Shall be pve sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe. meeting
ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTM 2321 for pve pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.1 and 2 of the International Residential Code. All building sewers shall be 6" diameter.
All installation= hall be "oocn trench" inspected and approved by the Carmel Sewer Department before any backftlline is done. Non-
compliance may result in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sewer inspections should be requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street
must. he cut. a senarale street cut nerpit shall he ohmined.
APPLICANT NAME: RE GROCE
PAYMENT RECEIVED BY: ?C? YI ?t
FEES:
$1,396.00
'F Regional Waste District
Residential RAN111reav Qr_wco tororu I r
00596 INDIVIDUAL LOT/ EXISTING BUILDINGS
Permit Type
---------- Final
----- --------------- ----
Subdivision
---------- Stanford Park
---------------- - -------
Section Number 2B-
-----------------
Lift Station
Lift
---------- 23 126th. Street Station
------------------------
--
Treatment Plant -
MIX
Builder _ _ _ __ _ _ _ __ Ryland Homes
Phone Number
------- 846-2783
------------------------
ParcelAcreage
EDU.in Gallons. ----------------------------^ 310
I
Lot Number ______ 1208
Address Number 13455
Street Cu ertino Ln
---------------------------------=--
ciWestfield
city -------------------------------
Zip Code 46074
County ------------------------------ Hamilton
Local. Sewer Charge
- ------ -------------------
Plan Review and Inspection
- - ----------------
Application Fee $100.00
-- ----------------------
EDU Fee $1,650:00
Interceptor Fee.
Invoice Number Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste i
District (see reverse) and any conditions noted below. All installations' shall be inspected by District personnel during
"open trench" phase and before backflling with stone to twelve inches above the pipe.. NO footing or foundation '
drains, or other sources of ground or, stormwater,, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for,
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner; developer or builder)
will be responsible for damages to'the District's sewer system: This includes damages to manholes,, castings,
manhole, lidsand the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing six months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH SFP-742 SFP-741 DSMH
Grease Trap
------ No
------ Slab Foundation
-- No
----- Lid Elevation 915.53 It
------ -------- 917.14 ft
-----------
Grit Interceptor
----- No
--- - Crawl Space - No
--- First Floor Elevation 918.40 ft
---------- 918.40 ft
----------
Grinder Station No Basement Yes Basement Elevation 909.40 It 909.40 ft
Calculation is based on. both Manhole Lid. Elevations and the elevation of the First Floor 2_$7t 1.26
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure, no illegal connections have been made.
Manholes shall remain accessible at all limes. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met. Connection to the sanitary sewer is now permitted.
By signing below, I attest that I am familiar .with the District's spear tions and agree to accept responsibility for all work done under this permit.
Builder/Owner Signature hone Number
Printed Name Z G?Z?
Approved By Permit Date 9!2512007
Candy J- Feltner, Director of inistratand Customer servi*
Revised 7/26107 Permit invalid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
1 No foundation or other storm water drains shall: be interconnected to'the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the, building to the septic tank may only be used if it is located under a building
addition, patio, porch"orpaved , driveway. Air test is:required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance. with the Distrct's sewer use ordinance. Such notification shall'be made 24 hours
priorto the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due.. This must be paid
prior to the time of the follow up inspection..
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
,private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe'and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,.
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number8 stone backfill material is to
be placed.from 6 inches below to 12 inches above the pipe. The trench.should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall'be installed no closer than 20 feetfrom water wells unless PVC pressure: grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can.be located on our web site
at http:J/wvw.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A.Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 644.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig'. IUPPS 1-800-382-5544, 48 hours prior to digging
Revised 724/07
7bs Schneider Corporation RO&MIAI Note:
8901 Otter Akre smnft This drawing is based on construction plans or record drawings,
Malaria Tort Bnrima taubm" A m61tadmw and is not based upon a field survey. The Schneider Corporation
Iodlaoepdy myepe 406-1097 (a Us does not warrant the accuracy or sufficiency of this information.
317--7100 Galau Contractors should verify existing conditions prior to any
1117-87E-72OI 71I construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately, failing to do
This Plot Plan Prepared For.
R.H. of INDIANA
Lot # 208 , containing 6,378 S.F.d:, in
Stanford Park Sec. 28
Instrument #200600049043
Plat Cabinet 4, Slide 126
Hamilton County, Clay Township
Sec. 29, T1BN, R3E
13455 Cupertino Lane _(50' R/W)
Carmel, IN 46074
Prepared Date: 09 20/07: By. AMA
Proposed Buyers : Franklin &
Marjorie Huff
Community Restrictions:
Side Yard = 3'
Rear Yard = N/A
Aggregate = 6' B.H.
Zoning = R-2, ROSO
Finished Floor Elevation Information
Pod Grade = 916.2 per plan
Pod Grade + 01 = Garage FFE (916.9 )
Garage FIFE + 1.5' = Residential FFE (916.4
, )
Residential FFE - 9.0' - Basement FFE:(909.4
Note : The garage finished floor elevation
is 1.8' above the curb at the drive, per
plan.
Sidewalk to be placed
online with from property line,
5' from back of curb,
per plop.
DRAWING
1. LJ
z
Q
J
O
Plot Plan Legend so results in the contractors assumption of all liability.
® Grraades
Existing Note:
?0p0.0? Cantom Grade The basement elevation, depicted hereon, has been determined
* A
p
pax
r
Lateral Location and based on the pad grades and/cur contours taken from
a 5
o
d
?y
SewerSewamlkNm
? the construction plans for this subdivision. Unless staled, no
- v Wat
er'SwAcs Linn Information about fluctuating water lables, sop condition%i or
--- -- Sub-Surfoee,Drain Liwa sop types has been provided or stated in sold plans. This lot
O Mardiale'(Smltary or slam) Is located near a body of water. Lot or sad conditions may
Beehhw Wat (Storm)
i
n
en
' require that the basement floor elevation be held 2 fool
D F? Sec
o
(st
o
) above normal pod elevation. Site investigation may be
Ai Fire Hrt needed if water is encountered during the excavation process
- • • - - ... - Flow_L}ia of cede or If other known water elevation or sop conditions are
_
present. Investigation and any remedial procedures Is at the
discretion of the builder to determine and take appropriate
steps of action. If any ground water is encountered during
excavation the builder is encouraged to contact The Schneider
Note: Sanitary Sewer Corporation to discuss possible courses of action.
Top of Costing Informatioon
Upstream Manhole, TC=915.53
Downstream Manhole, TC=917.94
per record drawing
Note: The contractor is to maintain
a minimum distance of ten feet (td)
between the sanitary sewer and
water line laterals.
Ground Cover Calculations
) Drive = 496 SF!
Public Walk =145 SFt
Private Walk =103 SFr:
Hydroseeding =n/a SFt
Sod =410 SY3 , from
entire yard
UPSTREAM SANITARY MH NOTE
The upstream sanitary manhole
T.C. elevation shall be no less
than one foot ( 1'-D') below
residential F.F.E.
I g --,
I
T-
-1 ' f-
I 9I
4 4.5
I
I o
o ,,
s
i
? gg
c?
36.a'
1100
a
30
0'
.
J
I B-B : ,.... ...
I
I yil w
TR./ 742
C= 15.53
PER RECORD
DRAWING
rc
Note: Sump pump(s) to be
placed by builder as needed
Note: Builder to ensure
positive drainage away from
structure(s).
LOT # 208
VB # 07.0079377
M
141.68'
16.2
m?
err
p
o?o
0
Assumed North
Scale: I' = 30'
° Io
I?
K?
m
9aNAM : DATE
3
4vr •i aPE
SNARK FBIWO R 0WI NAMON OF RECF.PT of PLOT PLW BY WSTOWR. - I.t
T ICAL SWAIE XCAON
Note: This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or o Surveyor Location Report.
Fkwd Hazard Slztement The accuracy of any flood hazard data shown on this report is subject
to map scale uncertainty and to any other uncertainty In location or elevation on the
referenced flood insurance rate map. ALL of the within described land DOES NOT l1E within
that special flood hazard zone A as said land plots by scale on flood insurance rate mop
+18057C 0205F for the City of Carmel, Indiana (maps dated February 19, 2003).
ILd CD
I? o
m
Kxj
w. .
FLOOD HAZARD STATEMENT
CERTIFICATION
?\\\\\?\ Gt\5 rI ERV'•/7?7i? /?G
S0303
STATE OF _
' (- . 4