HomeMy WebLinkAbout07090151 Sewer/Water Permit/sCITY OF CARMEL / CLAY TOWNSHIP
LeLVOI4( .
WATER / SEWER PERMIT / RECEIPT
\.Gp1ANR ? /PARCEL ID #: 1713120119014000
LOT & SUBDIVISION: 33A-13 LITTLE FARMS
ADDRESS OF CONSTRUCTION: 1222 TURNER CT INDIANAPOLIS, IN 46280
PAYMENT RECEIVED FROM:
Name: SENTRY HOMES, INC.
CHECK #: 043062
EXCAVATOR INFORMATION:
Name: SENIOUR CONSTRUCTION
Ph. #: (317) 862-6889 Fax #: Email:
Street Address: 6024 E ROCKLANE RD GREENWOOD, IN 46143
Bond Expiration:
PERMIT TYPE: USEWRWATR , SEWER/WATER PERMIT
Special Notes/Conditions:
Permit #: 07090160
Date: 10/01/2007
LOT 33A-B LITTLE FARMS. TOWNHOME IN 2 TOWNHOME
BLDG. WATER CONNECTION PERMIT. ADDRESS UPDATED
PER BILL AKERS OF COMMUNICATIONS ON 9/28/07.
' NO NOTES'
The building & Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 3' of latest revision: or vitrified clay pipe, meeting
ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTM 2321 for pvc pipe and the Uniforrn Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.1 and.2 of the International Residential Code. All building sewers shall he 6" diameter.
All installations shall be "open trench" inspected and approved by the Carmel Sewer Department before aria backfilline is done. Non-
compliance may result in digging up the sewer installation and/or denial of future sewer permits and!or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sever insnections should be requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street
must he cut a senarme street cut nennit shaft he obtained.
APPLICANT NAME: JENNIFER DENNIS
PAYMENT RECEIVED BY:
FEES:
$1,396.00
CITY OF CARMEL
Item 1 of 1
PERMIT RECEIPT
OPERATOR: slilla
COPY # : 1
Sec:12 Twp:17 Rng:3 Sub:096 Blk: Lot:33A-B
PARCEL ID ........: 1713120119014000
DATE ISSUED.......: 10/01/2007
RECEIPT #.........: 26397
REFERENCE ID 4 ...: 07090160
SITE ADDRESS .....: 1222 TURNER CT
SUBDIVISION ......: LITTLE FARMS
CITY .............: INDIANAPOLIS
IMPACT AREA .......
OWNER .......... ..: SENTRY HOMES, INC.
ADDRESS ........ ..: 801 ASHTON PARKE DR.
CITY/STATE/ZIP . ..: GREENWOOD, IN 46143
RECEIVED FROM .. ..: SENTRY HOMES, INC.
CONTRACTOR ..... ..: LIC # XSENCON
COMPANY ........ ..: SENIOUR CONSTRUCTION
ADDRESS ........ ..: 6024 E ROCKLANE RD
CITY/STATE/ZIP . ..: GREENWOOD, IN 46143
TELEPHONE ...... ... (317) 862-6889
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC
-------- NEW BAL
----------
---------- ------------- ------
USFWATCONN FLAT RATE ----
1.00 -------- --
1310.00 0.00 1310.00 O.AO
UNATERTAP FIAT RATE 1.00 86.00 0.00
--- 86.00
--------- 0.00
----------
TOTAL PERMIT -- -------- -------
1396.00 0.00 1396.00 0.00
METHOD OF PAYMENT AMOUNT
-- NUMBER
------------------
----------------- ----------
CHECK 1396. 00 043062
TOTAL RECEIPT 1396. 00
4 Regional Waste District
D ;4
00490 v v~
,ANITAKY SEWER PERMIT
INDIVIDUAL LOT/ EXISTING BUILDINGS
Permit Type
--------- Final
------- --
Subdivision Little Farms
Section Number
Lift Station
01 jCarmel Creek Station
Treatment Plant
------ Carmel WWTP
--------------
Builder -------------- ---- Sentry Homes
Phone Number'
Parcel Acreage
-----------------------------
EDU in Gallons 310
Invoice Number
Lot Number 3.3_A_-13
Address,Number
Street Turner ® C-f-
_
City
---------- Indianapolis
----
Zip Code - -------
46280
County ---------- ------- ----_--- - Hamilton. C?u
r
Local Sewer Charge ------- ------------------- t ?/
Plan Review and Inspection Q? -
Application Fee $100.00
EDU Fee
Interceptor Fee
----------- ZZA1
-------------------
Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the Districts sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest down stream'manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in,advance.,All new construction will be placed on billing six months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH CM-9A CM-9 DSMH
Grease Trap -- - - - -- - No - Slab Foundation No: Lid Elevation 829.31 R 829.11 R
-- - - ------------ -----------
Grit interceptor - -No Crawl Space Yes First Floor Elevation 832.20 it 832.20 ft
---------- ----------
Grinder Station No Basement No Basement Elevation
- - - ---------- ----------
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 1;89 3.09
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: EjectorPulfi30 r[I H 1A
4'The District reservesthe.right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible.at all times. Buried manholes will be corrected by. the Developer/Owner.
Conditional Permit Terms:
All conditions have been met Connection to,the sanitary sewer is now permitted.
011%0
By signing below„ I attest that I am fani liar with the DistnI s/pay?fications and agree to accept responsibility for all work done under this permit;
Builder / Owner Signature ?? ?!/yo cL-?CfG." Phone Number
Printed Name
Approve Permit. Date 911712007
Candy J.'Feltner, Director o/Admrnistratrar.6 Customer Service
Revised 7/26107 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains-shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located undera building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the Districfs:seweruse ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional.fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner.' Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM'D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND NO MORE'THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone orNumber 8 fractured face aggregate. Number 8 stone backfill,material is to
beyplaced from 6 inches below to 12 inches above the. pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
a. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR.35 pipe and.pressure grade SDR-21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10: Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the.Districfs office during
business hours'of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at,http:t/www-ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire.isto be placed on top of the lateral.
The District inspector_will verify placement of the. wire. After inspection, bedding is to be placed on top.
15. Call before.you dig. IUPPS 1-800-382-5544, 48 hours prior to digging
Revised 7/24107
PLOT PLAN
LOT ##33 /A-B
LITTLE FARMS ADDITION TO HOME PLACE
TURNER I c_4
HAMILTON COUNTY, INDIANA
ZONING
Side= 7.5'(min) 15' (AU.) /Rear- 20'
(AS SHOIH ON THE. REODRDED PLAT)
FINISHED FLOOR ELEVATION HOUSE = 832.20
FINISHED FLOOR ELEVATION GARAGE =830.90
ELEVATIONS
PROPOSED 00.0
NOTES:
- 1edTY Wm SEXe' UmK
LOGTION FM TD CU67RA M
S WL Vmy RE
MOO NS OF TIE DLILM AS SHA1N
PROR TO CON67RUCRON.
- awk ENW TO CXON TO LaaT.
STD. PLAN 16-01
- SMW SAWAIV, APO W M LK
LODUM ARE SM IA'Ql IIE
ODN57RA RM RAW FOR TARE MBAR
ADO" 70 HIAIEPVCE
i
401 Camby Court
Suite 'A°
Greenwood, Indiana 46142
Offim - 317-884-3020
Fm - 317-884-3025
A.MAM-.Mi nim
I,SZTRVEYING, Inc.
PREPARED FOR
SENTRY HOMES. INC.
801 Ashton -Parke Drive.
Greenwood, Indiana 46143
of-p ennits
Or Riau 9?B piue
Z1370
g
ag a T.
63.40' DBCHARGE LINE
56.44'
sz87
10' D.E. _
CONC. STOOP STR.
__-
-
TAT 33A-A t T 33A-B m
'
c 0 dL 4,8M LE R.r.SA
20 .
vmi 34.91 34.91
? c
m
01
M r
N _ ao in `n C-4
PROPOSED
. PROPOSED
r o I `? r RESIDENCE RESID CE
N
00
27.5.
1
DRrrE
14.92" 3' WUL
so'
Ex SAN. LATERAL g 3
L=23.56' ' TT
5' WALK _Tr;;
Ceal.I-g
PAM NOT TO BE
ALT 24. 2007
,,,?-EX. SAK LATERAL
-/EX. SAN. SEWER
162'
T C= _?
9.1 z9. i I.
STR/OY
SEX. STORM SEWER
SIR./102
w-
WATER LINE
- DIMID 50IS PRINAIM
EE16Ef1! T0. W er IN
Sheet 1 of 1
IOW MoLrr gas.
'DON'T DIG BLIND'