HomeMy WebLinkAbout07090152 Sewer/Water Permit/sCITY OF CARMEL / CLAY TOWNSHIP
j WATER / SEWER PERMIT / RECEIPT
101AVF
PARCEL ID M 1713120119015000
LOT & SUBDIVISION: 33B-A LITTLE FARMS
ADDRESS OF CONSTRUCTION: 1217 TURNER CT INDIANAPOLIS, IN 46280
PAYMENT RECEIVED FROM:
Name: SENTRY HOMES, INC.
CHECK #: 043068
EXCAVATOR INFORMATION:
Name: SENIOUR CONSTRUCTION
Ph. #: (317) 862-6889 Fax M Email:
Street Address: 6024 E ROCKLANE RD GREENWOOD, IN 46143
Bond Expiration:
PERMITTYPE: USEWRWATR
Snuri?l Nnfnn/rnndiftnnc-
SEWERNVATER PERMIT
Permit #: 07090154
Date: 10/01/2007
LOT 33A-A LITTLE FARMS. TOWNHOME IN 2 TOWNHOME
BLDG. ADDRESS UPDATED PER AKERS 9/28/07. MICHAEL
MERGELL (DEVELOPER) AND JENNIFER DENNIS (OF BLDR)
HAVE BOTH SAID THESE WILL CONTAIN REO'D 2 HR WALL.
' NO NOTES'
The building K Sewer Shall be pve sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting
.AS'ID1 specifications C700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer,
shall be installed in accordance with ASTM 2321 for pve pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent Ciw of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a). and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6' diameter.
411 installations shall be "open trench" inspected and approved by the Carmel Sewer Department before any backfilling is done. Non-
compliance may result in digging up the sewer installation and/or denial of fature sewer permits and/or denial of water connections.
No footing or foundation drains or other sources or&7ound water or storm water shall be permitted to enter the public sewer.
Sewer inspection- should be requested at 1317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumber bond posted with the CITY ENGINEER `S OFFICE. If any street
must. he cut. a senamte greet cut nermit shall he obtained.
APPLICANT NAME: JENNIFER DENNIS
PAYMENT RECEIVED BY:
FEES:
$1,396.00
CITY OF CARMEL
Item 1 of 1
PERMIT RECEIPT
OPERATOR: slillard
COPY # : 1 -? i
Sec:12 Ttp:17 Rng:3 Sub:096 Blk: Lot:33B-A
PARCEL ID ........: 1713120119015000
DATE ISSU-ED....... : 10/01/2007
RECEIPT #.........: 26398
REFERENCE ID # ...: 07090154
SITE ADDRESS .....: 1217 TURNER CT
SUBDIVISION ......: LITTLE FARMS
CITY INDIANAPOLIS
IMPACT AREA ......
OWNER ............: SENTRY HOMES, INC.
ADDRESS ..........: 801 ASHTON PARKE DR.
CITY/STATE/ZIP ...: GREENWOOD, IN 46143
RECEIVED FROM ..... SENTRY HOMES, INC.
CONTRACTOR .......: LIC ## XSENCON
COMPANY SENIOUR CONSTRUCTION
ADDRESS ..........: 6024 E ROCKLANE RD
CITY/STATE/ZIP ...: GREENWOOD, IN 46143
TELEPHONE ........: (317) 862-6889
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT
---------- ------------- ---------- ---- --- ----
USFWATCONN FLAT RATE 1.00 1310.00 0.00
UWATERTP_P FLAT RATE 1.00 86.00 0.00
---------- ----------
TOTAL PERMIT 1396.00 0.00
METHOD OF PAYMENT AMOUNT NUT43ER
----------------- ------------ ------------------
CHECK 1396.00 043068
TOTAL RECEIPT 1396.00
THIS REC
1310 00
86.00
1396.00
NEW BAL
0.00
0.00
-----10.00
Regional Waste
Residential
00487
Permit Type- ,------- - - Final
?Subdtvtsion'
---- -----
It#ie
L Farms
---
Sebti6n Number -
lift Station 01 Carmel Creek Slabcinl
Treatment Plant Carmel WW fP
Builder _ Sentry Homes,
Phone Number
Parcel Acreage
EDU in Gallons`
lnvoice',Number,
-31
I]
of
drains;
will.be re
manhole
ground or:stormwatef, shalt be`per€n'i'
lily for drains whichiare below'the?g?e
i beneath driveways or sidewalks. Th
ages to,the DistrcrsPsewer sysfem:'T
aused,by=construction: activity on;the
owner,
Inspections by the`pisglct are MANDATORY'and:shall beairanged;by contacting,'the District's°offce.at 844-9200
-24 flours in advancer All'new constructionwil be placedron billing six;mor ths:afterconnection has'beeniriade or
when,water Is connected whichever, comes first:
The building has: USMN CM-9A CM* DSMH
Grease Trap --- V - No Slab Foundation No lad Elevation 82631°ft 829.11 ft"'
Grit-Interceptor No Crawl Space Yes First. Floor Elevation's 830.56 it 830.`50ft-
'Grinder Station No Basement No, BasemenEElevation
- - - - - - - - - - -- - - - - - --- - - -
Calcufatipn is'basedon boffi.M nhole Lid Elevations and_tiie elevation of the FIM FiOOr -1 19'. 1.39
J_
Per Oidiriance 8-13,99 @nd•il e:etevavons provided the,substructurersha11 be plumbed b
The,Qistricbreserves the iighl to inspect elsump,pump oonnectlonsto'ensure no litegal;connec&ons have been-made
Manholes, shall, remainiaccessibie at all times. Buried Manholes'
Conditional P,ermit.Terms:;
All conditions have been met
By signing below, I,attesltnalJ am familiar wdh..iheDistrict's sspecclificati6ns and,agree to'aocept-iesponsil ity lor:all. work done. una rt
Builder!Owner.Sigriature ?.P.hon_e slur fiber
Printeii Name ,?!rCd C
Approved - Yerimit..' Date 911712007 I r, ... ... - ._ anon B.Cusfwner Se.vice .
Revise-d,Vnd7r permifis valid for,0NE-YEAR 'frdni the date issued. Permit valid only with CTRWD sea[ in red'!nk.
SANITARY SEWER PERMIT
INDIVIDUAL LOT j,EXISTING BUILDINGS
Lot Nurri 331EI-A.
_
Address Number - 1217.
Street
.
- - ---'
TurnleraCrt;
-----
-----
City -------- -__ Indianapolis,
Zip. Code: .46280 Fer
_ _
------
County --------
Hamilton
Local;SewerCharge.
------ -- ----- -_?----
Plan Review and,lnspe.ction
- -- -- -
-
-- - - --- --
Application Fee> -- - -
-
$140 00
??
EDUTee, - $1 6SO OOn '
Interceptor Fee '
FeesMue 31,750.00;
of the Clay Township Regional Waste
be inspected byDistnci personnel during
SUMMARY of LATERAL INSTALLATION REQUIREMENTS'
4. All houses„buildings, etc.; shall connect to the,District'ssanilary-sewer system;withm 9o days otnotice.providing°a
sewer is within ,300 feet for' Hamilton County orNDO feet for Boone County dkhe property,line_ Only 'one budding may
conneciJ6 the,§ewermain periateral unless otherwise approved.by the District-
2. No-fpundatido or'other storm water drains-shall be interconnecteTtoahe.sewer lateral.installedarnd•connected to;
ine District s sanitary sewer:
3. The eisting,sewer Ime"fr m the building to:theseptic'tank may only be.used'if.it,is located under;a.buiiding
addition; patio, porch or paved driveway. AirtesVis required to show if acceptable for re-use The property owner
shaiCbear the cosj:o_f all testing;, _TheDistncLinspector must,be onsite for the duration of the,air test,
4. The owner of contractor'shalLnotify the District;pnor to covering the,.installed:,lateral so that the District canfmake an
inspection to determine. compliance with the Districts sewer use ordinance Such notification shaPbe made 24 hours
pror'to,the need for the, inspection. Ifthe inspection fails`and a second inspection is required or coniractaris not on
(site for scheduled inspection, or-failsAo cancet.inspection, an additional fee•of 5100.00 wilftie due. This must'.be paid
prior•to•the timaV,4 a follow up mspectio°n:
,maintenance;of
cfion-to a public
nal or stone in:,a
nation and to notify
PVG:PIPE: tSDR'3516rSDR 26, ASTM D3034; 'SIX, INCH PIPE
PVC;PRESSURE'RATED PIPE: 'SDR^21, ASTM D22At, SIX INCH PIPE
RESTRAINED JOINT PVc:PIPE;(DIRECTIONAL DRIL(i: Yeiomine'SRD,21,
ASTM D2241r SIX INCH PIPE (us&only perapproval of'the•District Engineer)
GASKETED JOfNTS:'ASTM 153212
GASKETS:.ASTM 6477
FITTINGS.'.SDR 26 or better,(NO fernoo's allowed)
DUCTILE'IRON-MECHANICAL,000PLlNGIVVITH PROPER FITTINGS
CLEAN OUTS TO BE LOCATED NO MORE,THANTHREE FEET FROM THE
FOUNDATION AND NO MORE 'THAN;100'FEET APART.
7. Bedding; Use N1Jmber8 crushed stoneor Number SWactured face aggregateNuriber 8.stone backf 11 material isito
'be placed from 6 ihches below to 12 inches above the pipe The•trench shouldbe a minimum of 1$ inches wide (s z'
inches an both sides`of thepipe)
ins20 feet frorrilwater wells unless.PVC tallation requiring pressure pip shall be evie ed a and accepted bytiiie
e
SDR,2lralnd ASTM D2241 y I p posed than
Distnct and tt e.pistnct s.en sneer nor to installation.
9. Where a transdion is made between SDR 35 pipe and,pressure grade SDR21 pipe, 'a ductile iron gasketed
meclianicai coupling -shall ,be'used:
10:. Laterals shall terminatewitliin 3:feet df the.building.unlessthe conditions.in items#3 above are'me6 No glued pipe
shall be installed out'side•three feet of building foundaiion,walls.
11, Additional.information on District standards and'specifcatlons;maybe obtained•from'the Districtts office:dunng
business hours6f•6:60a;m: to 4.3o.p.m `Monday through Friday, A11 District siandards,ca , be located on ourwab"site
at fittp:llwww.ctrrrd. org/.
Clay Township Regional Waste:'District 1070,1 College Avenue - Suite A Indianapolis, Indiana 45280
,ptic.effluent shall not be' pumped outinto fhe sanitary sewer system.
12, Se
13: The'Dlstdct shall.inspectrALL laierals. Please cad;the District offiice.at 844"9200 24: hours prior to time of.
14. Contractors shall.lay 14;geuge-solid wire the entire length' ofthe_Iateral. Wires to be'placed on top of theta teral.
TNe'.Distri ct inspector'will verify placement of:lhe wge:, After inspecticn,,bedding is to.be,placed on top.
15- Call before you dig. IUPPS 1-80,0-382=5544, 48, hours prior to'digging,
Revi547;N/07'
6.. Acpepfa6le.Pipe?Materials:-
PLOT PLAN
LOT 33B- A
LITTLE FARMS ADDITION TO HOME PLACE
1217ATURM
HAMILTON COUNTY, INDIANA
ZONING
Side= 7.5'(min) 15' (4&) / Rear- 20•
(AS SHOWN ON TO NBCORDSD PLAT)
FINISHED FLOOR ELEVATION HOUSE = 830.50
FINISHED FLOOR ELEVATION GARAGE =829.20
ELEVATIONS
PROPOSED 0070
NOTES:
- VERIFY SANRARY SEWER LATERAL
LDDIRON PRCR 70 COLSTRLCIION
BIADMjaXRd1= SNU Vffy 71E
DI E100% OF T1E RUM AS %M
PRW M 0016ffUCRON
- ORVE BM TO COMFO Y M ID.U
STD. Rm 1s-01
- saU SWDIRY, AND wum UVE
LOGITM ARE BSSED UM DE
COLSIRL W ft" FOR UTRf MW
ADORIOV TO HaMR +LE
q 3v 31 CE%. SAN. SEWER
i
SAN. LATERALS
M STORM SEWER
_
TURNER
L=23.88' C OL t'(- f s WALK
E%. WATER UNE
ONC.
I
C 3 WNJ
}
3 1
?L
DRIVE
2
F.Y.SB
1 0 23.08' 1 23.08' 0 3.8'
i
a; o, m
11.83' - ' 11.83' y rmii
-
$ PROPOSED I
PROPOSED > M
m RESIDENCE RESIDENCE ^
v
t ,?
Y
i
.9
341' I
3491' ^ 00
n
BM
2D RY.SB.
La
IDT33B=A l LOT 33& SR
3A c ac
_ CONC. STOOP
59'
44 58.71'
.
SUMP PUMP SUMP PUMP
DISCHARGE LINE DISCHARGE LINE
HOW ? UM
'DON'T DIG BLIND'
KPOINTE
401 Cmnby Court
Suite 'A"
C=mwood. Tndia 46142
Office-317-AR4-3020
Fay - 317-9943025
&VAM-m pu?igg .e
SURVEYING, Inc.
PREPARED FOR
SENTRY HOMES, INC.
801 Ashton Parke Drive
Greenwood, -Indlana 46143
Call Pe
for omits Plus
or Ric 928-6447
6
gz?,il
O
co
I
mmovtw?c an,c?u,q ,w.
Y OR 06DRIUlM US COMMA
NOT NAMM It ACa1RACT OF 91R>44 Y W 7M5 NFDNA1101.
aaRACM % LL VLR/Y ALL DOM C0Rq m PR10R m AMY
00A:0GR WY AM ALL NSMACES SKL' E Bt0114R m THE NOT 10 BE SGIID - pMENSIDNS PRc/ALfM)
:"rIYM" ".?°R°?.°W">E.o HAMM. ,° oo so IDS.... °e °tr`.°sm, d ? Sheet 1 of 1.