HomeMy WebLinkAbout07100030 Site PlanAI%IP
The Sabnelder Corporstion
8901 Otte Avenue
®etatie port Hem on
Indlempolls, mdMne 406-1037
317-826-7100
917-82e-7200 PAY
&Illineedy
SM-7119
landscape Areblteetare
GIs • us
Gedop
Plot Plan Legend
This Plot Plan Prepared For R.H. of Ind ® Proposed Grades
Lo # 979 , containing 6,490 S.F.t, in DOO.O Existing Grades
Village of Westclay ?1GWO. Contour Grade
Section ?00ry,2 * Approx. Lateral Location
Sanitary Sewer Lines
INST. It 200500060673 - err - Storm Sewer Lines
PC 3, SUDE 791 - v - Water Service Lines
i
REPLAT INSTR 20060000694$ - - - - - -
0 - Sub-Surface Drain L
nes
Manhole (Sanitary or Storm)
PC 4, SLIDE 31 - ® Beehive Inlet (Storm,)
Hamilton Count , Clay Tap 19 Curb Inlet (Storm)
Sec 19 T18N OY
r D
A End Section (Storm)
Fire Hydrant
2461 Gwinnett Street (50'R/W) Flow Line of Swale
Carmel, IN 46074
- - - - - Building Line (BL / BSL)
-Easement Line
Prepared Dote: 09/21/07 : By. KAG
Proposed Buyer s?CASEY AND
ELIZABETH WATSON Note: Sanitary Sewer
Community Restrictions: Top of Casting Information
Side Ycrd = 5' MIN (ONE SIDE) Upstream Manhole, TC=904.63
Rear Yord = N/A Downstream Manhole, TC=905.97
Aggregate = 20% LOT WIDTH, MIN. 5' ONE SIDE per record drawing
Zoning = Sl
z
R.H. of Indiana OVE
Finished Floor Elevation Information rroICAL SWALE SECTION
TBM at face of curb=904.3
TBM a; alley-905.5
Proposed Grade at Swale=906.2, high side
Garage FFE at weatherlip=909.2-2.54=906.66 §RT
Residential FFE=906.2+3.0=909.2 PER RECC
Basement FFE=909.2-10.0=899.2 DRAWWG?
Ground Cover Calculations: TC-904.07
Drive = 666 SFi PER RECOF
Public Walk =239 SFi ORAVING
C%MdMM
Private Walk =41 SF+
Hydroseeding =N/A SFt
Sod =315 SYi , entire yard.
Sidewalk to be placed
flush from property line, -
5.5' from back of curb,
per plan.
Note:
The contractor is to maintain a minimum
distance of ten feet (I0') between the
sanitary sewer and water line laterals.
FLOOD HAZARD STATEMENT
CERTIFICATION
V57fRE:..
o: No.
S0303
STATE OF
Note:
This drawing is based on construction plans or record
drawings, and is not based upon a field survey. The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
piscrepancy found on this drawing should be reported to
e Schneider Corporation immediately, falling to des so
eisults in the contractors assumption of all liability.
The basement elevation, depicted hereon, has been determined and
based on the pad grades and/or contours taken from the construction
plans far this srbdivsim. Unless Stated. no hfomatim about
fluctuating water tables, son conditions, or sell types has been provided
a stated or, said plans. This lot Is located near a body of water. Lot
a son conditions may require that the basement door elevation be
hold 2 foot above normal pod elevatm Site investigation may be
needed if water is encountered during the excavation processor It
other kno.n water elevation or sots conditions are present
Investigatim and any remedial procedures is at the discretion of the
buider to determine and take appropriate steps of action. If my
ground water is encountered during excavation the bulder is
en=raged to cmtod The Schneider Corporalim to discuss posainle
courses of action.
Note: Sump pump(s) to be
Lot 979 placed by budder as needed.
V4.o7 000000 Nate: Sulder to ensure positive
b07 / O 00 drainage away from structure(s).
U
Note: (secondary areas -
Westclay) Max. height: 35' on
lots 100' and larger (lo eve line)
30' on less than 100' Max.
a o coverage: 50%
O Note: (primary areas - Westclay)
Assumed North Max. height: 30'
Scale : 1' - 30' Build-up line: 2 stories
Mm. coverage: 50%
GANNETT STREET, JGVNN
1BM-904.3 904.4 29.0
PER PLAN B-B
\ /-ROLL CURBI
Area of water tap to be restored
to its' original condition prior to
construction.
Granular back fell suggested
under driveway at sanitary
sewer lateral trench, water line
trench and any other excavated
areas. (If situation occurs)
Location of utilities on plat plan
ore general locations per plan and
should be verified in the field.
BASEMDIT PUMP
Ig) FIEHSON F
FRMAMSY
RESIDENCE
1Y
THREE CAR
GARAGE
CONIC
n.... 1- T.
12' ALLEY ESMT
v?
%Iniiruq r u n l u moal?r?
v. =905
I STR. / 133 PQ on AP
TC=905.97 ' ALLEY ESMT
PER RECORD - - -
DRAWING
This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or c Surveyor Location Report.
All service laterals
crossing at curb are
SIl stamped:
PU SA= Sanitary Sewer
SS= Subsurface Drain
W= Water
e,g
ITO Pad elevation shown is per plans
and is not the as-built
elevation.
p a
r-
1 The information for the elevation
• difference between the primary,
o finished floor elevation to the .
i top of basement wall and to
the basement finished floor was
provided by the client.
Area of water tap to be
back filled with granular
material to within 10'
of top of curb.
2_ AUEY
Flood Hazard Statement: The accuracy of any loco hazard data shown on this report is subject to map scale
uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL
of the within described land DOES NOT lie within that special flood hazard zone AE as said lane plots by scale on
flood insurance rate map #180081 0205 F for the City of Carmel, Indiana dated February 19, 2003.
SIGNATURE : DATE
SIGNATURE REPRESENTS CONFIRMATION OF RECEIPT OF PLOT PLAN BY CUSTOMER.
Note: Per Cannel zoning ordinance
26.1.1 : The residential district limit,
height to iwenty-five feet (25?,
however a dwelling may be ncreowd in
height to thirty-fvx feet (35) provided
the side and rear yards are increased
an additional one foot (1) fa each one
foot (1') the structure exceeds the first
twenty-five feet (25) in height.