VIA HAND DELIVERY
Mr. Jon C. Dobosiewicz
Department of Commun ity Services
City of Cannel
1 Civic Square
Cannel, Indiana 46032
RE: Development Plan and ADLS Approvals for West 106lh Properties, LLC, Docket
No. 62-02 DP/ADLS
Our File Number: 3214.002
Dear Jon:
Please find enclosed the. colored drawings of the ground sign to be installed for West
lOGth Properties, LLC's project to be located at the southeast comer of 106tl1 Street and
Commerce Drive,
To the extent that you have any questions or if I can be of any (urtller assistance to you,
please do not hesitate to contact me. Thank you very much for your cooperation and assistance in
this matter.
Very truly yours,
DREWRY SIMMONS PITTS & VORNEHM, LLP
~ C~ cf/- -'hr tfU.VtJ.-(
Mark T. Monroe, AICP
Land Use Planner
Enclosures
(J:Il'eislaw\ClielltsIS- TISwisslJ \Ltr\Dobosiewicz 7.15.02,doc
. ~~:
~~,\. \
u U
DREWRY SIMMONS Plffi & VORNEHM, LLP
A T T 0 A N E Y 5
v
. "'_._------.-_._.._._.~----'-_.~._"
8888 Keystone Crossing, Suile 1200 . Indianapolis, Indiana 46240 . (317) 580-4848 telephone . (317) 580-4855 facsimile' '
February 5,2004
Angelina Butler
Department of Community Services
1 Civic Square
Camlel, Indiana 46032
Re: Cannel Centre West Office Building, Lot #2, Docket No. 04010005 ADLS Amend.
Dear Angie:
We have received your review letter dated .T anuary 14, 2004' regarding the Cannel
Centre West Office BUllding on Lot #2. Please find enclosed revised site plans tbat
address the following conullents:
1, . The legal description has been added to the plans.
2. Each tenant will have a wall sign located over the tenant space. The signs will be
individual letters, dark bronze in color and back lit. Their allowable size is
dictated by the Sign Ordinance.
3. The drive at the rear of the bui Iding wi 11 be used for the loading berth.
4. All easement have been labeled on the plan.
S. No rooftop mechanical equipment is planned and the dumpster area will be shared
with Building #1.
6. Building dimensions have been labeled on the plans.
7. We have not received a letter from the Urban Forester but we have addressed in
plan fonn his verbal comments from the T AC meeting.
8. Your comment is duly noted.
9. The 10 ft. path was shown on the previous plans.
Also, please find enclosed responses to the review letters that we have received to
date. Tfyon have any additional questions regm"ding this project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration of this matter.
Very Truly Yours
Drewl'y Simmons Pitts & V omelml, LLP
.~~o.y'.~~
Mark T. Monroe
Attomey for West 106tl1 Properties, LLC
Enclosures
2'-0.
STONE CAP
E.IJ.S. SIGN FACE
2'x2' BRICK PIERS
STONE WATER TABLE
SPLIT FACE TEXTURE CONC.
MASON RY BASE
10'-0'
1'-0'
'CARMEL CENTR .
....... ,-:- WEST : . ~.:.'.
. .
. I .
c
CHANNEL LETTERS TO
MATCH STANDARD BUILDING
SIGNAGE
'"
I
;"
. . C
"
u
U
i"'"
One Civic Square
Carmel, IN 40032
(317) 571-2417
Fax: (317) 571-2426
To: Uv/~;
Fax: .5J' CJ - -f1 ~:?
Phone: ..5J'tI ~ #~ Date:
/;/e;;-/ C}2//Yie/ Qa-l~~ 6'/cc.j.g
Re:Oy/7Je/Q/)!e/'"" UieJ,L f~~ A'j cc:
From~ JVce
I
Pages:
-:7-/,;) -&0\
.
o Urg.ent
D For Review D PJease Comment 0 Please Reply
o Please Recycle
2)c9c,t:el /1/0. 6 d-o~ JJ~/A..lJ.L..5
To: >flu/ ~/~
FaJC 6(ftJ-$-S
Phone: 6if tJ - ~J!f9'.
Re: /{;rend&? '7-/~ -o~
u
u
One Civic Square
Carmel, IN 4E032
(317) 571-2417
Fax: (317) 571-2426
From: W/"Q!;,
.
Pages~ ~
Date: 1~1' "'00\
CC~
o Urgent 0 For Review 0 Please Comment D Please Reply
o Please Recycle
tyesf O,r/ne/ ~/1~r 6/cc~ <3-
Cdyme/ Ce-o-kr ffe,i ~e $cy.r.
~i2 -00< j);:;/A-ZJ4:S .
u
/~~c-'7j...... _
/'\ \" --- -,..,' .~,
If>>/ . ~ ~<(\
t-t RECEIVED \\~').
'. . tl J{JN 21 2002 .t
Transmlft~:I, DOCS ,:~~
\/'. )/
'/>::l~ ,,'/
';:~.. .. -.~". ~. /'
, , ';,T I I _/'
, --
u
r
6845 E. US 36, Suite 500 It Avon · Indiana 0461230317.272.0108. FAX 317.272,04121'1 www.schneidercorp.com
TO:
John Dobosiewicz
City of Carmel
One Civic Square
Carmel, IN 46032
DATE:
JOB#:
PROJECT:
RE:
6/26/02
4179.001
. 5/3 Bank - West Carmel Center
Site Plan
FROM: Dan Schnur
FAX:
DIRECT DIAL:
WE ARE SENDING YOU:
[g] Attached Via: 0 Mail [g] Fed Ex 0 UPS 0 Courier 0 Pick Up 0 Other 0 Fax
FAX#:
NUMBER OF PAGES:
TELEPHONE #:
# Copies Date Description
1 Revised Site Plan
THE ABOVE ARE TRANSMITTED as checked below:
o For approval
o For your use
REMARKS:
o As requested
[Z] For review and comment
o FOR BIDS DUE
o Other
COpy TO:
File
if enclosures are not as noted, kindly notify us at once.
Offices inlndianapofis, Avon, Carmel, and Lafayette, Indiana
p:\4k\41791001 \docs~cd062602-2.doc
To: ~/ ~ /:S
Fax: .5rYtJ - 4/'d~~
.U
u
.-
One Civic Square
Carme;I, IN 4E032
(317) 571-2417
Fax: (317) 571-2426
From:
Jpt2
..z;-~/ C~ Ii' fZ r
6-027- OOt.
,
Pages:
Date!
Phorte~
. -sL:tdC / ~/ ..J14; q/ izJ ~
. Re: ~rA.J't:L,.~"1
cc:
o Urgent D Fer Review 0 Please CQtnn1ent 0 Please Reply
o Please Recy.:::le
7?~4..rtL /7~'
#7
~ c:2 __ 0;;; ..2);0 /A-LJL..$ Wft J-/ a.,.-/11 (? / c:!,.? '7
8 /oCk ..6' -
C~;n€,/ C-/r h/LJ:~ ~~ 8t'J
q
~
I
I
l
,I
I
!
-
u
u
08/0"L
$;L.:PCM..
-
~~~fu:r-_~.a C5~')
I
J~ .
.
\,oJ \) 9.~L.1.L"" . ___
,
----.-1-
=_=-_-~~lll-> ~~
7 ii
I
______ ;_ Gt>w~.lJ.:~A( ~~I~
i,
Hl
I
'I~~
,.. .vJJ/~_L4d>IIf.!.S_~ ____
- ---- - -- - ~.$l:f. p....,,- ~~_. ~__
.-- ---.-'! ~-P-~ ~ .J2~
l::J'~ '- ~ ",VL"7I ~_~ _
~~t!:; J.D ~K
_-_~~___l"'~-~n .~- ___ --- ~~~=~~______~~-_______m-~~__~
._ - -- -~,,'.;,i, =J l> ------, ---.. -- - -. --'.- - --. ---- -- - - - - -. -- --- - - ----
~-fML~~T>ffJI.I8.;..- . .. ___ .--___ .._____._._____ .__.. -----,
- :~,
: il!
-~----- -r"'J
- --- -- .H- ---------
I
, ~
I
__J
,
u ---1
J
i
--------------1
I
_ - - -. . J
-- ----~
I
. ------ rl - -
,
I
I
i
~
I
----I
I
# --------.-- - -
J
,.~ "
W"~ ',. \j
QREWRY SI!vtM~NJ; ~::~~~;&Y()RNE~f.l, L@t1. P:.;:~;:7J~~;;'"
, Ulv Ie ' Ic-"j
eJ' 1'1 Pt70P 1--:: J
\:\ uocs.~t
8888 Keystone Crossing, Suite l200 . Indianapolis, [ndiana 46240 . (3l7) 580-4848 telephnnt: . (317) 5811-4855 f3csimiJe . www.drewrysilllm.ls.com
\"*'~.~ . ,.;0/
, --Y
!~; tG\ .
- \
\
June 11,2002
Mr. Jon C. Dobosicwicz
Department of Community Services
City of Carmel
1 Civic Square
Carmel, Indiana 46032
RE: Development Plan and ADLS Approvals for West 106th Properties, LLC, Docket
N o';i62..D"2"DP/ADLS
Our File N;r~~4.002
Dear Jon:
Please find enclosed the "cut sheets" for the proposed lighting to be installed for West
1061h Properties, LLC's proj ect to be located at the southeast comer of 1061h Street and
Commerce Drive.
To the extent that you have any questions or if I can be of any further assistance to you,
please do not hesitate to contact me. Thank you very much for your cooperation and assistance in
this matter.
Very truly yours,
DREWRY SIM1VfONS PITTS & VORNEHM, LLP
.,/~
Paul G. Reis
"oJ
Enclosures
G:\reislaw\Clients\S- T\Swiss\l \Ltr\Dobosiewicz 6-ll b-02,doc
I 0 -../
I " .,
CARMEL CENTE:R
Type: A Mfg:
TWIN HEAD POLE ASSEMBLY
c@us
LISTED
l.isted for wet loeatlons
The AutoLux is a low profile, sharp cutoff luminaire, designed for automotive dealership lighting.
Combining a high performance multi-faceted segmented reflector with versatile light distributions and a
variety of mounting capabilities, the AutoLux is the superior choice for your lighting needs.
Quality engineering and computerized state of the art machinery join together to set the new standard for
quality in the lighting industry.
~
lA:i'i I '"~ I~
. Wattage
Optics
7/T' ~.T"
." ..{. ,--~.... . d..,/L
Sounoe Volta B
Source Voltage
Mounting
~d
Finish
Options
Model No.
Mounting
Finish
Options
o ALX-1 0 Type I ~ o 1500 OM-i 0120 o Bolt~On Arm o Bronze o Photo Cell
(T1) (1500) (M) (1) (BOA) (BZ) (PC)
o ALX-2 0 o 10.00 DPS 0208 o Sllp-FitArm o Quartz Restrike
Type II ~ (1000) o Black
(T2) 0750 IP) (2) (SFA) (BK) (QR)
o Typelll ~ (750) o HPS
0450 . 0 240 D Knuckle Mount o White o Light Shield
(T3) (450) IS) (3) (KM) (WH) (LS)
o Type IV ~ 0400 0277 D Wall Mount o Green o Single In-Line Fuse
(T4) ( 400) (4) (WM) (GN) (SF)
[I] 0350
o Type V (350) 0480 o Gray o Double In-Line Fuse
(T5) 0320 (5) . (GY) (OF)
(320)
D 250 o M.Tap o Custom
(250) (6) (CC)
0200
(200)
o 175
(175)
0150
(150)
o 100
(100)
Fnl mo~ :d1!!:~~lIerj i,.,lo;malioll Of; maun'iflg, wilili~', D~ iroslal:aliM :I'lWur::iOrs. please wn<i-lIll ramol}'_ ~J"I~ lhat I~ Pc.les ~i~ r.OI ;).Idereo i\"~:h flxtUII:!S, please SD-ef~l\j ins m;Jun~l1~ loquirrn1f:1!'.. Tr
dOCl.lr.".et11 cCir'1\ain.s ProDiill-:.ar-j IIItorrnalilJl1 u! Vlsin~ai,.e log-h1il'lg,lL:-. ~n~ use o~ 1h"tl- inf\llmatlGn ~"quirr.s ihl': w.rltlen spp.ro\lel orV,~i",r\aift! Lighli;;~. LLC.ln kl!8'O,n9 wilh our iO~, ~{]Ii-cy [jrm1~I"IIJCfl
impcrt)lfemenl" V~looairc fe$~,'Ie" 1118 ri~h\ ,'.; d1;:mgie. an~i specif,c.a~<;"'s ooll~ajne-d herei~1 withoul prim noliei'.
217 East 157th Street. Gardena, California 90248
Ph (310) 512-6480 Fax (310) 512-6486
VVVV'IN.visBoll'1aireUi gh1:i ng .com
hI )(.'ll
u
AutoLux S
Housing.
.Allhousings are manufactured using technologically advanced
computer numerical control (CNC) machinery. Precision
sheared and formed, .080 gauge, corrosion resistant aluminum.
. The computerized (CNC) machinery enables all AutoLux
housings to be constructed quickly, efficiently, and adhering to
exacting ISO 9002 standards. All external hardware is
stainless steel.
Lens and Door Assembly
. Door assembly is (CNC) precision, sheared and formed from
.080 corrosion resistant aluminum and Quali-Guard@ finish.
. The lens is a tempered clear safety glass, secured by
aluminum lens retainers and sealed with form fitting silicone
gasketing.
Optical System
~ The Optical System is (CNC) cut and bent, providing precise
and consistent, mu Iti-faceted 95 percent reflective systems for
IES types I, II, III, IV, and V distributions.
Quali-Guard@
. The finish is a Quali-Guard@ textured, chemically pretreated
through a multiple stage washer, electrostatically applied,
thermoset polyester powder coat finish, with a minimum of two
mi. thickness. Finish is oven baked at a temperature of 400
degrees fahrenheit. to promote maximum adherence and
finish hardness. All finishes are available in standard and
custom colors.
BotfmOn""Arm Detail
--t---
2"
----.-f-- -E)
t 2h"
5" - t - - -8
J 2h" I
-~---!...,.- -8
u
ecificafions
Mounting
. An extruded aluminum, bolt-on-arm with continuous channels,
securing (2) 3/8 inch zinc running bolts with stainless steel
hardware is standard. Extruded aluminum arm is premounted to
. fixtures by Visionaire.
. Optional slip-fit arm provides ease of installation. This is
recommended for retrofitting existing poles.
Electrical Assembly
. Ballast is factory wired and tapped to voltage specifications.
All ballasts are CWA or HPF regulating auto transformers,
available in Metal Halide, Pulse Start, and High Pressure
Sodium. Ballast is capable of providing consistent lamp
starting down to -20 degrees fahrenheit 8allast is fastened to
an easily accessible ballast tray for service convenience.
. Socket is a glazed porcelain medium or mogul base with nickel
plated contacts, rated at 5K and 600V.
Options
. Fixtures available with a variety of options, including photo
cell, quartz restrike, light shield, and fusing. Please consult
factory for custom options.
Listing
. AutoLux is UL listed, suitable for damp and wet locations.
All fixtures factory tested and prelamped prior to shipment.
c@us
LISTED
SlipmFit Arm Detail
o~
o
-l-
7"
I
_.1'__,0
I
I' 0
'~7~
~~:
,
o
; 2" I
, '
,
Adjustable Knuckle
217 East 157th Street, Gardena, California 90248
Ph (310) 512-6480 Fax (310) 512-6486
VVVll'vv.v i siona ij re! i ghti 1119 .com
u
u
Streight Square Poles
AQ, and AR Series: Anchor Base
Tenon Top or Side Mount
Capped
Tenon Top (Post Top)
TENONS: 23; B" or 3", Tenons are 6061- T 6 aluminum; for other
optional tenons, contact Shakespeare. Post top fixtures,
flood lights. or brackets mount with ease,
Square Shrouds
OPSH-AQ for all AQ series poles'
OPSH-AR for 01/ AR series poles
Square Poles
Anchor Base
ANCHOR BASE: Cast A356-T6
aluminum, polyurethane coated
to match pale color.
Bolt
Hole
Circle
_h
Hot dipped galvanized steel
anchor bolts (4" x 4" poles: 5/8" x
21" x 3"; 5" x 5" poles: 1" x 30" X 4")
complete with nuts (2) and
washers (2) are supplied
standard,
I
~ I
SQuare4
I~
Square Poles Anchor Base Dimensions
Bait Hole
Series Circle Drovvlng Square Hole Pole Size
....
Mounting
Height
(Snaft Length)
-,
r
18" Std.
8"
13/16" 6' to 16'
1,25"x2.0" 6' to 30'
AQ
AR
Square
Square
7,4"
11 "
)1,1"
-~",.'\
. Ie
./)
4i;j)
~r:~i
Page 14
..J
","i
U How to OrderU
A complete Shakespeare Fiber-
fi~) glass Pole Catalog Number includes
all of the information detailed below,
in. order from left to right including
the dash. The lett~rs and numbers to
the left of the dash are the Basic Cata-
log Number, found in the listings of
the poles. To the right of the dash are
the options which you can specify in
the order listed. Most available options
are listed in the template below. Call
Shakespeare for all other options.
To decide which Shakespeare
fiberglass pole you need, first consid-
er your application: anchor base Or
direct burial (Shakespeare re~om-
mends direct burial far cost efficiency
and ease of installation), round or
square, regular or breakaway, and the
method of luminaire attachment.
Using your required mounting
height, wind speed, and the total EPA
and weight of aU intended attachmen-
ts, select a pole. with loading ratings
that meets your needs.
The Basic Catalog Number is list-
ed in the catalog pages (plus two dig-
. its after the dash for mast arm poles).
The remainder of the Shakespeare
Catalog Number defines options, ac-
cessories, .colors, etc. Please use the
Shakespeare standard specification for
these options whenever possible.
You can assemble your own cata-
log numbers, or call Shakespeare for
assistance. If you need help choosing
or specifying, Shakspeare's experi-
enced staff will be glad to help.
Shakespeare Fiberglass Poles Catalog Number Template
SERIES
(from Spec Charts)
SOH X
ABC D
Q R T
,A.dd
W
to Series
for
Break-
away
Poles
BASE TYPE
A=Anchor Base
B=Direcf Burial
BASE TYPE
SERIES
BREAKAWAY
LUMINAIRE MOUNTING
OO=Copped Only (not predrilledl
OT=3" Tenon (T9/16' min. ID x 30// long)
02=20h" Tenon (13/1~" min. ID x 33// long)
03=4" Tenon (31/." ID x 6" long) . not available on AS 10 Ihru 25
or 8S 10 thru 25
04=3" Tenon (25/8" ID X 2" long . AO and BO only, Suitable (or
most inline ballast fixtures
OB=Copped and predrllled for single Shakespeare 8" to 14" arm
09=Copped and predrllled for twin Shakespeare 8" to 14"arms
lO=Ccpped and predrllled for single Shakespeare mast orm
20=Ccpped and predrilled for twin ShakespeOle most arms
15=Ccpp.ed and predrllled for Shakespeare 15' truss arm
25=Copped and predrilled for two Shakespeare 15' fruss arms
99=Other (specify)
(Not Mounting Height) I I
I
. CATALOG FIXTURE FINISH & COLOR HANDH
LENGTH (ft.) MOUNTING
30 1lIIl!l 01 N2 B
,
A S W
I______________J
Base Catalog Number
NONE
18" Anchor Bose only
54"
66"
7811
~ Distance )
from Base of
Pole
90"
102'
01her (specify)
2'12' x 5"
Oval
AA
BB
BC
BE
BG
BI
BK
BZ
FINISH
N=Natural . S=Smoofh
Color Natural Smooth
Block .Nl 51
Gray N2 52
Brown N3 53
Green N4 54
Dr. Bronze N5 55
Silver N6 56
White N7 57
Other N9 59
(custom)
OLE
CONDUCTOR
ENTRANCE
B
1
I I
~---------_______J
Options
CONDUCTOR ENTRANCE, SIZE AND LOCATION
1 eo. 2 ea. 1 eo. 2 ea.
2'!~" 2';," 21//x6" 2'1/'x6"
Grommeted No Grommef
NONE OJ 01 OJ 01
12" - 38 39 42 43
24" ~ Distance ) 08 09 12 13
36" from Base of 20 21 24 25
48" Pole 32 33 36 37
60" 44 45 48 49
Other (spacifv) 99 99 99 99
Is something missing? In order to simplify ordering aHd streamline this manua I, Shakespeare lIas omitted a selectiol1
of infreqitC/1tIy specIfied options and dimensions. I71ese are still available on request. Call Shakespeare for further il1formatiol1.
HANDHOLE (with removoble cover)
(sorne models)
4"x6" 4"x12"
Oval Oval
AA AA
CB DB
CC DC
CE DE
CG DG
CI DI
CK DK
CZ DZ
Page 7
~:~~{ ;~f:':-'. ~\Mi~~~=-" '...~?~
w
cf~l~~~eaut
rr'@';: V,!Ei~~lf,!I8.~"J,:? ;
U . .
Straight Square Poles .'1~11~
. ~~~
AQ and AR Series: Anchor Bose :~~~
Contemporary styli ng
fV)
.'
POLE DIAMETER SUGGESTED MAXIMUM TOTAL LOADlNC;;
STANDARD
NOMINAL HANDHOlE BOLT !>ASIC
MOUNTING SHAFT POL~ SHAFT SHAFT LOCATION TOTAL 80 MPH 9Q MPH 100 MPH 120 MPlI HOLE CATALOG
HEIGHT LENGTH WEIGHT TOP BASE FROM IIASE WEIGHT !:PA' EPA" EPA" . EPA' CIRCLE NUMBER COMMENT
(Fl.) (Ft.) (lb..) (In.) (In.) (In.) (Lb..) (Sq. Fl.) (Sq. Fl.) (Sq. Ft.) (Sq. Ft.) (In.)
6' to 16' mounting heights - STRAIGHT SQUARE 4"x4" (Series AQ)
6 6 18 4 4 18 150 23.2 17.9 14.2 9.4 8 AQ06 Smooth. Bronze
8 8 23 4 4 18 150 16.5 12.6 9.8 6.1 8 AQ08 Smooth. Bronze
10 10 27 4 4 18 150 12.0 8.9 6.7 3.7 8 AQ10 Smooth, Bronze
12 12 31 4 4 18 100 9.1 6.5 ' 4.6 2.1 8 AQ12 Smooth. Bronze
14 14 35 4 4 18 100 6.7 4.4 2.8 0,7 8 AQ14 Smootti. Bronze
16 16 39 4 4 18 100 3.7 2.2 1.1 8 AQ16 Smooth. Bronze
6' to 30' mounting heights - STRAIGHT SQUARE S"XS" (Series AR)
6 6 41 5 5 18 200 99.4 78.2 63.1 43.3 11 AR06 Smooth. Bronze
8 8 51 5 5 18 200 76.4 59.9 48.1 32.7 11 AR08 Smooth. Bronze
10 10 61 5 5 18 200 61.5 48.0 38.4 25.8 11 ARlO Smooth, Bronze
12 12 71 5 5 18 200 51.0 39.6 31.4 20.8 11 AR12 Smooth, Bronze
14 14 82 5 5 18 .200 34.5 26.6 21.0 13.6 11 AR14 Smooth. Bronze
18 18 102 5 5 18 200 25.9 19.4 14.9 9,1 11 AR18 Smooth, Bronze
20 20 113 5 5 18 150 22,3 16,7 12.6 7.4 11 AR20 Smooth, Bronze
v~?5 25 138 5 5 18 150 15.9 11.4 8.1 3.9 11 AR25 Smooth, Bronze
() 30 30 164 5 5 18 100 8.6 5.1 2.6 11 AR30 Smooth.. Bronze
A Q series
. 4" x 4" Straight Square design
. Mounting heights to 16'
. Smooth finish
. Bronze color standard - pigments
integrated int? the resin
" UV and weatheHesistant pig-
mented polyurethane coating
. Tenon Top or Capped for side
drilling
. EP A ratings are the same for capped or tenon top poles,
. Poles can be predrilled for bolt-on side mount fixture(s), arms, etc.
. Fiberglass shrouds (1- or 2-piece) optional.
. A,II EPA calculations are based on poles with hondhoJes,
AR series
. 5" x 5" Straight Square design
. Mounting heights to 30'
. Smooth finish
. Bronze color standard - pigments
integrated into the resin
. UV and weather-resistant pig-
mented polyurethane cooting
. Tenon Top or Capped for side
drilling
Standard Handhole: 2112" x 5" oval. Ali hand hole covers are polyurethane coated to match pole color,
* All EPA, recommendations, including 120 mp'l, are calculated per AASHTO standards and include a 30% gust ioctor
Page 15
Innova~ Forlns For Cast-in-Place
Lighting Poles-Signs"BoUards- Flagpoles- Floorlights-Piers
118 Sandford Drive" Stouffville, Ontario, Canada L4A 7X5 " TeL (905) 642-3225 .. Fax (905) 642-3227
~r
12"
J
*
VARJADLE
UP TO.J.6"
~.
IJ-
"
16" 01,1..
* U')CAl1QFiOfOmONAL ...CCENiCOLORUANU
NEWAVEA 510R-HIGH
w~vw.ArtFO RMS ConcreteBases. com
U.s. DISTRIBUTOR - G. A. MASLONA ASSOCIATES" TEL. (716) 674-9233 ., FAX (716) 675-6468
u
u
www.ArtFORMSConcreteBases.com
ztj"DrA.
1S"DIA.
2U"DJA
20' DlA.
I ,( 1B"D1A. ...,J
l'
'1 J I
UPID
12' lr
J t' Ii
J 18"DIA. l
,
NEWAVEA S10R-LOW
~r
i1r
)~
1S"DI'"
o
o
o
*
u D [
UI'TD
or
UI'TO
36-
'.DIA.
l, 10"01A. "L
.~}~
o
o
o
I.
r
lB"OIA.
,L
J
'e~ PIA.
y
MODUA SOOR
NEWAVE4 stDR-HIGH
J
'2"DIA,
I.
,
1,
r-
24' DJA.
2Z" DIA.
(1
0081-4 305R
UP
~
I
*1
i
ENOTE m
0-
m
~
r
r
901A.
,
r
A 01A. ':~L
I 8DIA.
I'
( t
I '~H
(
B DIA. t
SE
CLASSICA 255R
CLASSICA 305R
CLA.SSICA 480R
CLA.SSIGA 6tOR
~
13" 10" ~.75"
15" '2" 3.75"
22.5" 16" 5.5"
30" 24" 775"
H
(
-
)
llQIES.:
~
r
B D1A.
-/
B H
10"
12" UPTO
lB" 30'
24"
2. OIMENSIONS SHONN ARE IN NOMlNAL INCHES
~. THt.~ SKETCHGS OEPfCl' rA~-;'lN..PI Ar.~
ARCHITECTURAL CONCRETE BASES V1A
SINGLE-USE ArtFCRMS CONCR"TE FORMS.
J
24'DlA.
J
CUSTOM MAROSE 255R
CUSTOM MAROSE 305R
CUSTOM MAROSE 460R
CUSTOM MAROSE 61DR
3. -t lNDtCAT"t='s.OPTlONAl S:;:LF-lOCK}NG
Jo!..UMINUM COLORACCBil BAND FOR
HORIZONlAL REYEAl(SJ.
KELLAMY 610R
. j<;~~, :.~(,(:,t~,. .
'(r,c-?,.;'''!''..,'':'
'<"u ,j"-. .,;/:l::~-,.
CAST-IN-PLACE
ARCHITECTURAL CONCRETE BASES
for...
SITE LIGHTING POLES. FLOOIJUGHTS. LIGHTING & PROTECTIVE BOLLARDS
R.AGPOLES ' COLUMNS, SIGN POSTS, GAZE'f30IFYWIUONiPERGOLAlTRELUS POSTS
FENCE/GATE POSTS, PORCH POSTS. DECK POSTS. DRIVEWAY LAMP POSTS. OrnER' CUSTOM
ArtFORMS International Inc. Vi.'WW.ArtFORMSConcreteBases.com
EMAIL: ArtFORMS@ArtFORMSConcreteBases.com TEL: 905-642-3225 FAX: 905-642-3227
ArtFORMS Architectural Concrete Bases are casl-in-place on the jobsite by the Property OWf'ler's
construction Contractor by means of versatile, cost-effective, single-use ArtFORMS Concrete Forms
:J
CARMEL CENTE:R
Type: Al Mfq:
SINGLE HEAD POLE ASSEMBLY
I
nr-
C
-_L
c@us
LISTED
Listed for wet locations
The AutoLux is a low profile, sharp cutoff luminaire, designed for automotive dealership lighting.
. Combining a high performance multi-faceted segmented reflector with versatile light distributions and a
variety of mounting capabilities, the AutoLux is the superior choice for your lighting needs.
Quality engineering and computerized state of the art machinery join together to set the new standard for
quality in the lighting industry,
Model No. Oplics IDDDI Mounting IDI Options
ALX
Model No. Optics Wattage Source Voltage Mounting Finish Options
o ALX.1 0 Type I ~ o 1500 OM-! 0120 o BolI-OhArm o Bronze o Photo Cell
(n) (1500) (M) (1) (BOAI (BZ) (PC)
o ALX.2 0 o 1000 0208 o Quartz Restrike
Type II ~ (1000) DPS o Slip-Fit Arm o Black
(T2) 0750 (PI (2) (SFAI (BKI (QRI
~ (750) 0240
o Type III 0450 o HPS o Knuckle Mount o White o light Shield
(T31 (450) (S) (3) (KM) (WH) (LSI
o Type IV ~ 0400 0277 o Wall Mount o Green o Single In-Line Fuse
(T41 (400) (4) (WM) (GNI) (SF)
0350
o Type V - (350) 0480 o Gray o Double In-Line Fuse
(TS) 0320 (5. (GY) (DF)
(320)
0250 o M.Tap o Custom
(250) (61 (CC)
0200
(200)
o 175
(175)
o 150
(150)
o 100
(1001
Fj,lr tnQ~ c-e:a.iloeo;;'lf'If::;rmalw on mounling. wi!in;g, 01 illlilallaliGI\ ill'"lrddi:1:;;, pleD-~e ~r,sun iamr-,;. N-:\e :h<ll it Foles (I'~ '101 o'dele.cJ with fixt:J,-es" p1ea.e spe:ity l;o~ ",olJntin~ ~El~tjjrf:im~n1.. T ~
dJ':urnenl c.onla:ns. ",lC'Pji~lary iflllJ~ma~OII 01 Vii:llunair,o L;9~,ling, LlC. Any lJ;e or 1M!:!. inlD::i1;;:li{lr, reQu~r(os IPc "'Ii~e-n appro~'al of Visionil"e Li'9h1in~, LLC, In ke-eping wiV ourl QM oo-lic!, 0: (;~tnLJO
irj,PTo'eme-;l;. VlsiOllail'6 r6PJr"e~ the lighllil c.18ngB allY :iJ€dr!';;aiion~ r.r1~Tei::ie:1 ~e(.ein wi:r.oui pl'i1)1 nOlle€!.
217 East 157th Street, Gardena, California 90248
Prl (310) 512-6480 Fax: (310) 512-6486
vvvll'vv. visuonail"elii!!9 ('1I::(ng_ com
AL}(.1.
u u
AutoLux Specifications.
Housing
. All housings are manufactured using technologically advanced
computer numerical control (CNC) machinery. Precision
sheared and formed, .080 gauge, corrosion resistant aluminum.
. The computerized (CNC) machinery enables all AutoLux
housings to be constructed quickly, efficiently, and adhering to
exacting ISO 9002 standards. All external hardware is
stainless steel.
Lens and Door Assembly
. Door assembly is (CNC) precision, sheared:and formed from
.080 corrosion resistant aluminum and Quali-Guard@ finish.
. The lens is a tempered clear safety glass, secured by
aluminum lens retainers and sealed with form fitting silicone
gasketing.
Optical System
. The Optical System is (CNC) cut and bent, providing precise
and consistent, multi-faceted 95 percent reflective systems for
IES types I, II, III, IV, and V distributions.
Quali-Guard@
. The finish is a Quali-Guard@ textured, chemically pretreated
through a multiple stage washer, electrostatically applied,
thermoset polyester powder coat finish, with a minimum of two
ml. thickness. Finish is oven baked at a temperature of 400
degrees fahrenheit. to promote maximum adherence and
finish hardness. All finishes are available in standard and
custom colors.
lB.oltmOn-Arm Detail
--...---
2"
- f - - ;l~ - - 8
5" - i - - -8
! 2~" I
-------- -0
:~
I
I
Mounting
. An extruded aluminum, bolt-on-arm with continuous channels,
securing (2) 3/8 inch zinc running bolts with stainless steel
hardware is standard. Extruded aluminum arm is premounted to
fixtures by Visionaire.
. Optional slip-fit arm provides ease of installation. This is
recommended for retrofitting existing poles.
Electrical Assembly
. Ballast is factory wired and tapped to voltage specifications.
All ballasts are CWA or HPF regulating auto transformers,
available in Metal Halide, Pulse Start, and High Pressure
Sodium. Ballast is capable of providing consistent lamp
starting down to -20 degrees fahrenheit. Ballast is fastened to
an easily accessible ballast tray for service convenience.
. Socket is a glazed porcelain medium or mogul base with nickel
plated contacts, rated at 5K and 600V.
Options
. Fixtures available with a variety of options, including photo
cel!, quartz restrike, light shield, and fusing. Please consult
factory for custom options.
Listing
. AutoLux is UL listed, suitable for damp and wet locations.
All fixtures factory tested and prelamped prior to shipment.
c@us
LISTED
Slip-Fit Arm Detail
-r-
to U
;~_ 0
T'
~:
,
o
Adjustable Knuckle
217 East 157th Street. Gardena. California 90248
Ph (310) 512-6480 Fax (310) 512-6486
VlfVVV\r. vi si ana ire I i 9 h 1l:i ng .COI1l'1l
Capped
w
.U
Straight Square Poles
AQ, and AR Series: Anchor Base
Tenon Top or Side Mount
e),
Tenon Tap (Past Top)
TENONS: 23/8" or 3". Tenons are 6061~T6 aluminum; for other
optional tenons, contact Shakespeare, Post top fixtures,
flood lights, "or brackets mount vvith ease,
Square Shrouds
OPSH-AQ for 01/ AQ series poles
OPSH-AR for 01/ AR seriespoJes
Square Poles
Anchor Base
Bolt
Hole 0
CircZ..,' ~Q
Hole QUO
-~
Square-+[
1<-
ANCHOR BASE: Cast A356-T6
aluminum. polyurethane coated
to match pole color,
Hot dipped galvanized steel
anchor bolts (4" x 4" poles: 5(8" x
21" x 3"; 5" x 5" poles: 1" x 30" x 4")
complete with nuts (2) ond
washers (2) are supplied
standard.
Square Poles Anchor Base Dimensions
80li Hole
Series Circle Drowing Square Hole Pole Size
~
Mounting
Height
(Shaff Length)
I
18" Std.
_v_l_
AQ
AR
8"
11 "
Square
Square
\3/16" 6' to 16'
1.25"x2.0' 6' to 30'
-
7,4"
11.1 "
Page 14
,,:.
U How to Orde"rU
t')
A complete Shakespeare Fiber-
glass Pole Catalog Number includes
all of the information detailed below,
in order from left to right ~ncluding
the dash. The letters and numbers. to
the left of the dash are the Basic Cata-
log Number, found in the listings of
the poles. To the right of the dash are
the options which you can specify in
the order listed. Most available options
are listed in the template below. Call
Shakespeare for all oth~r options.
To decide which Shakespeare
fiberglass pole you need, first consid-
er your application: anchor base or
direct burial (Shakespeare rel;:om-
mends direct burial for cost efficiency
and ease of installation), round or
.square, regular or breakaway, and the
method of luminaire attachment.
Using your reqillred mounting
height, wind speed, and the total BPA
and weight of all intended attachmen-
ts, select a pole with loading ratings
that meets your needs.
The Basic Catalog Number is list-
ed in the catalog pages (plus two dig-
. its after the dash for mast arm poles).
The remainder of the Shakespeare
Catalog Number defines options, ac-
cessories, colors, etc. Please use the
Shakespeare standard spec~fication for
these options whenever possible.
You can assemble your Own cata-
log numbers, or call Shakespeare tor
assistance. If you need help choosing
or specifying, Shakspeare's experi-
enced staff will be glad to help.
Shakespeare Fibe'rglass Poles Catalog Number Template
LUMINAIRE MOUNTING
OO=Capped Only (not predrilled)
01=3" Tenon (19/10<< mill. ID x 3'/4" long)
02=23 h" Tenon (l3f 10" min. ID x 3'! / long)
03=4" Tenon (3'/4" ID x 6.' long) . not available on AS 10 thru 2S
or as 10 thru 25
04=3"Tenon (2518" ID x 2" long . AO Dnd SO only, Suitable tor
most inllne ballast fixtures
08=Copped and predrilled for single Shakespeare B".io 14" arm
09=Copped and predrilled for twin Shakespeare 8" to 14" arms
lO=Cdpped and predrilled for single Shokespeare mast arm
20=Copped and predrilled for twin.Shakespeare masi arms
15=Copped and predrilled for Shakespeore 15' truss arm
25=Copped and predrilled for two Shakespeare 15' if'JSS arms
99=Other (specify) .
SERIES
(from Spec Charts)
SOH X
ABC D
Q R T
Add
W
10 Series
for
Break-
away
Poles
BASE TYPE
A"Anchor Base
B"Direct Burial
SERIES BREAKAWAY CATALOG FIXTURE FINISH & COLOR HAND HOLE
LENGTH (ft.) MOUNTING
S W 30 .. 01 .N2 BB
I I I
----~~~__.~.-----.J <.--_---~---- ~~
Base Catalog Number Options
HANDHOLE (with removable cover)
21/2" X 5'1 (,ome models)
411x611 4"x12"
Oval Oval Ovol
NONE AA AA ."..A CONDUCTOR ENTRANCE, 51
1 B" AnChor Bose ani)' BB CB DB 1 ea.
5L1' BC CC DC 21/<"
66' ~ Disio f,ce ) BE CE DE Gramm
78' from Base of BG CG DG NONE 01
90" Pole BI CI DI 12" 38
102" BK CK DK 24" Distencs 08
Oiher (specify) BZ CZ DZ 3611 from Bose of 20
Pole
B,L\.SE TYPE
I
I~~_-
J8~
~
)
FINISH
N=Natural . S=Smooth
Color Natural Smooth
Black NT 51
Gray N2 52
Brown N3 53
Green N4 54
Dr. Bronze N5 55
Silver N6 56
White N7 57
Oiher N9 59
(custom)
CONDUCTOR
ENTR.Il,NCE
01
I
~~~~~J
ZE AND LOCATION
2eo. lea. 2ea.
2'// 2112"x6" 21/,"x6"
eted No Grornmet
32
44
99
01
39
09
21
33
45
99
01
43
13
25
37
49
99
60'.
Other (specify)
01
42
12
24
36
48
99
Is something missing? 111 order to simpl(fy ordering and streamline this manual, Shakespeare has omitted a selection
of infreqi.iently specified options and dimensions, These are still available on request. Call Shakespeare for further mJormatiol1.
Page 7
~}~~1i18$~"Ji, ;:iWr~~^~'~~\'1
u
rS~
11[,'::.; ,": ';$Ih!.eE" -18?'71'\ ,~. :
U
Straight Square Pol.es
AQ and AR Series: Anchor Bose
Contemporary styling li~
;~~i~'~
li?l
POLE DIAMETER SUGG~STED MI'.XIM UM TOTAL lOADING
STANDARD
NOMINAL HANDHOLE BOLT BASIC
MOUNTING SHAFT POLE SHAFT SHAFT lOCATION TOTAL 80 MPH 90 MPH 100 MPH 120 MP~ HOLE CATALOG
HEIGHT LENGTH WEIGHT rop BASE FROM BASE WE'IGHT EPA' EPA* EPA* , EPA* CIRCLE NUMBER COMMENT
(Fl,) (Fl,) (lb,,) (In.) (In.) (In.) (lb'.) (Sq. FI.) (Sq. Ft.) (Sq. Fl.) (S~. ~t.l (In.) '.
6' to 16' mounting heights - STRAIGHT SQUARE 4"x4" (Series AQ)
6 6 18 4 4 18 150 23.2 17:9 14.2 9.4 8 AQ06 Smooth. Bronze
8 8 23 4 4 18 150 16.5 12.6 9.8 6.1 8 AQ08 Smooth. Bronze
10 10 27 4 4 18 150 12,0 8,9 6.7 3.7 8 AQ10 Smooth. Bronze
12 12 31 4 4 18 100 9.1 6.5 4.6 2.1 8 AQ12 Smooth, Bronze
14 14 35 4 4 18 100 6.7 4.4 2.8 0.7 8 AQ14 Smooth, Bronze
16 16 39 4 4 18 100 3.7 2.2 1 .1 8 AQ16 Smooth, Bronze
6' to 30' mounting heights - STRAIGHT SQUARE 5"xS" (Series AR)
6 6 41 5 5 18 200 99.4 78.2 63.1 43.3 11 AR06 Smooth. Bronze
8 8 51 5 5 18 200 76,4 59.9 48.1 32.7 11 AR08 Smooth, Bronze
10 10 61 5 5 18 200 61,5 48,0 38.4 25.8 11 ARlO Smooth. Bronze
12 12 71 5 5 18 200 51.0 39.6 31,4 20,8 11 AR12 Smooth, Bronze
14 14 82 5 5 18 200 34.5 26.6 21.0 13.6 11 AR14 Smooth, Bronze
18 18 102 5 5 18 200 25.9 19.4 14,9 9.' 11 AR18 Smooth, Bronze
20 20 113 5 5 18 150 22,3 16.7 12.6 7.4 11 AR20 Smooth. Bronze
,~~ 25 138 5 5 18 150 15.9 11 ,4 . 8.1 3.9 11 AR25 Smooth, Bronze
<) 30 30 164 5 5 18 100 8,6 5.1 2.6 11 AR30 Smooth, Bronze
AQ series
. 4" x 4" Straight Square design
. Mounting heights to 16'
. Smooth finish
~. Bronze color standard - pigments
integrated into the resin
. UV and weather-resistant pig-
mented polyurethane coating
. Tenon Top or Capped for side
drilling
. EPA ratings are the same for capped or tenon top poles.
. Poles con be predrilled tor bolt"on side mount fixture(s), arms, etc.
. Fiberglass shrouds (1- or 2-piece) optional.
. All EPA colculations are based on poles with hond,lo/es.
AR series
. 5" x 5" Straight Square design
. Mounting heights to 30'
. Smooth finish
. Bronze color standard - pigments
integrated into the resin
. UV and weather-resistant pig-
mented pOlyurethane coating
. Tenon Top or Capped for side
drilling
Standard Hondhole: 2i // x 5" oval. All hondhole covers ore pOlyurethane cooted to match pole color.
* A/! EPA recommendations, including 120 mph. are calculated per llASHTO stcndards and include a 30% glJsi factor,
Page 15
\
V
Innovative Forms For Cast-in-Place
Lighting Poles-Signs- Bollard.<.- Flagpol es-Floorlights- Piers
118 Sandford Drive · Stouffville, Ontario, Canada L4A 7X5 .. TeL (905) 642-3225 · Fax (905) 642-3227
It
lU" DlA.
Il
18" D1A.
12"
*
1
VAlUABLE
UP TO 36"
j
^
IS" nlA.
J
,
* wc,.,noNr.l'f'Or'rjUI'f"'L..Ct:;'~:NTCOUJR.Il..ND
NEWAVEA 510R-HIGH
www..A.rtFOIU.1SConcreteBases.com
U.S. DISTRIBUTOR - G. A. MASLONA ASSOCIATES.. TEL. (716) 674-9233 .. FAX (716) 675-6468
w
u
WW'W.ArtFORMSConcreteBases.com
2V' DIA.
16"D1A.
?IT DIA.
{
~I
,"(
2O'DIA.
lB"OIA,
x'L
.(
l-r
16"011'..
'7
UP TO
n'
o
o
o
"
o lJ 0
UPTO
42""
J 1S'"DIIl J
NEWAVEA 51OR-LOW
U?TO
36"
12" OIA,
o
o
o
'0" Pill
.r
J
16' PIA.
,l
J
1S'DII\,
t.
/
'~
lIPTD
12"
---"".
MGDUA SOOR
NEWAVEA 51OR-HIGH
;,
12" DlA.
J
Z4"DIA..
~I:
r
*'1
i
l
SEENo~~'1
UPTO
36"
22"'011\.
:1
l
Ii.
I
I
I
OGBLA 305R
/"~
r:
.,
A OIA.
l' SOIA. :h
I ~
J
(
I ) '~ H
(
~
L B DlA. L
A B H
CLASS/CA 255R 13" 10" 4.75'"
CLASSICA 305R 15- 12- 3.75'
CLASSJCA 4.60R 22,5" ,a- 5.5"
CLASSICA 610R 30" 24- 7.75'
E\ 01.0..
H
ll!l!ES:
8 OIA.
"
1.THi;:;:SE.SKE'TCHES.DEP1er r"J.J..r.T.-lN-.pt M"::I=
ARCHITECTURAL CONCRETE BOSES VIA
S1NG\.E4.!SE ArlFORMS CONCRETE PO"-M5.
}
2<"01A.
J.
CUSTOM MAROSE 255R
CUSTOM MAROSE 305R
CUSTOM MAROSE 450R
CUSTOM MAROSE 6fOR
~
~
~UPTO
~ 30-
24" I
2.. mMENSlON5 SHOWN ARE IN NOMINAL lNCHES.
KELLAMY StOR
~. * INDICATES OPTIDNAl S~L=-{'OCK!NG
ALUMINUM COlORJ>.CCENT SAND FOR
HORIZCWlAL REVEI\L(S).
. . . ??...~t::tfl~)::f;~~
"" (I'c':;'~ry~\, 'cl'~~"
{':':~y"'{jtl": ~ .>:'~./u";
CAST-iN-PLACE
ARCHITECTURAL CONCRETE BASES
for...
SITE LIGHTING POLES. FLOODLIGHTS. LIGHTING & PROTECTIVE BOLLARDS
FLAGPOLES. COLUMNS. SIGN POSTS. GAZEBOIR4VILlONIPERGOLIVTRELuS POSTS
FENCE/GATEPOSTS. PORCH POSTS , DECK POSTS .DRII/EWAY/.AMPPOSTS. OTHER. CUSrGM
ArtFORMS Internalionallnc. wW'N.ArtFORMSConcreleBases.com
EMAIL: ArtFORMS@ArlFORMSConcreteBasescom TEL 905-642-3225 FAX: 905-642-3227
ArlFORMS Architectural Concrete Bases are cast-in-place on the jobsite by the Property Owner's
construction Contractor by means of versatile, cost-effective, single-use ArtFORMS Concrete Forms
.
UCARMEL ce:NTER
Type: F Mfg:
FLOOD
I
t----- B ~
1-c~
/ ~(
///?
'/;/
.-~/
.--r
A
/ uL
c@us
USUll
Li.le~ fo,wot loeati.ons
SFRB.1 & 2
< ~FiXfure " = ~ :B.l ~€; . :Max. Wajls: :,EPA' ..
SFM~1 9.25" 9.25" 7" 175w 0.7
SFR-1 7.75" 14.75" 13.4" 400w 1.1
SF 1...-1 17" . 17" 6" 400w 125
SFRB-1 10" 15" 7" 175w 1.2
SFRB-2 16" 16" 7.5" 400w 1.6
SFL-K 24" 24" 10" 1000w 27
The SmartFlood family of luminaires were designed and constructed for superior durability and
performance.The rugged housings and mounting variations provide versatility while maintaining
aesthetics, efficiency, and economics.
Engineered and constructed for superior adjustability, utilizing either an adjustable knuckle or trunion, the
SmartFlood's proven performance and light control make it the "smart" choice for a variety of general area
lighting applications. .
Model No.
Mounting
1c:J! Opt,,", I
Finish Options
o Bronze o Photo Cell
(BZ) (PC)
o Black o Quartz Restrike
(BK) (QRI
o White o Light Shield
(WH) (LS)
o Green o Single In-Line Fuse
(GNI (SF)
o Gray D Double In-Line Fuse
(GYI (DF)
o Custom
(CCI
Opllcs
Ic:JDc:J!
SFL
o 5FL-K
Optics Wattage . Source Voltage Mounting
0 Narrow Beam o 1 DOD OlVH 0120 o KnuckleMount
(NB) (1000) (M) (11 (KM)
0 0750 OPS o 20B D Trunion Mount
Wide Beam (750}
(WB) 0450 (P) (2) (TM)
(450) o KPS 0240
0400
(400) (S) (3)
0350 0277
(350) (4)
0320
(320) 0480
0250 (5)
(250)
0200 o M.Tap
(200) (6)
o 175
(175)
o 150
(150)
o 100
(100)
0.70
. (70)
Model No.
o SFM-1
o SFR-1
o SFL-1
o SFRB-1
o SFRB.2
fu! mUll' lklagl"d illlorm~~"lIlHJ mou~tin9' \'I'irifl~, -or ~stallaoon ifr.5lruc;tjoll:j;> pJlo!ool~e COl\SUn Ii:lQiO'). NfJl.e lI1al ir Po'~ ,lie nol Ci~telj: \'Alh fj~ure5, pl[!a~ SoPN:if)' m,"- mllun:ir.g re-qlJilm.e~t5_ Thi::
oOCl.lmenl !;ootail1.S p-r~~;etilry lIrlonrla~Ol1 oI1Jekina:ire Li9hlill9' I.lC."'",y 'Jst'''orl;tt~.s i:'lrOlrn.!l~OO lequirtsti1e...,ltl~n eppm\l.'!lDIVl~~nalre L~hlin!T_ LLC. k1 keepi.n~.""il/lOUI TOM poli:y 01 run,,!lJlJU~
imprQvelTlt:r1~ 'ils.iQ[Ib;re ~tSoerve:s IiH!rigttto (:h~~ an)' 5~~~lion~i:ontair.ed ~t{-inwh.~t{]tn pMrnOlite. '
217 East 157th Street, Gardena. California 90248
ilflNT'11iI1J Ph (310) ~1~~6480_ Fa~ (31~) 512-6486
b. \:"",..<c ., <" ,,,"' \i;o '.:"", v.lv.rvv.vlsaonaareBaghtlll1lg.com
5FL-1B
u u
SmartFlood Specifications
Housing
.; Rugged, one piece die-cast, soft corner aluminum housing
with 0.12 inch nominal wall thickness.
(SFM-1, SFR-1, & SFL-1)
. SFRB-1 & 2 and SFL-K, are precision formed'from c?rrosion
resistant aluminum, utilizing state of the art (CNC) machfnery,
designed to ensure accuracy and consistency in all fixture
housings, as well as a weathertight seal.
. All hardware is rust resistant stainless steel.
. All housings feature Visionaire's proprietaryQuali-Guard@ paint
finish, available in an array of colors.
Lens and Door Assembly
. Die-cast external hinged door frame is fully gasketed. A one
piece extruded silicone gasket seals the door frame against
the housing. (SFM.1, SFR-1, & SFL-1)
. The Lens is a clear tempered flat glass, completely enclosed
and gasketed for a weathertight seal.
Optical System
. The Optical System is (CNC) cut and bent, providing
precise and consistent, multi-faceted 95 percent reflective
systems for narrow and wide beam applications.
Quali-Guard~
. The finish is a Quali-Guard@ textured, chemically pretreated
through a multiple stage washer, electrostatically applied,
thermoset polyester powder coat finish, with a minimum of two
ml. thickness. Finish is oven baked at a temperature of 400
degrees fahrenheit. to promote maximum adherence and
finish hardness. All finishes are available in standard .and
custom colors.
Adjustable Knuckle
o
Mounting
. The SmartFlood luminaires are available with either a die-cast
aluminum, adjustable knuckle; designed to slip over 2-3/8 inch
to 3 inch 00. pipe, or an adjustable trunion "U" bracket, with
stainless steel hardware. Knuckles and trunion brackets are
premounted to fixtures by Visional.re.
Electrical Assembly
. Ballast is factory wired and tapped to voltage specifications.
All ballasts are CWA or HPF regulating auto transformers,
available in Metal Halide, Pulse Start, and High Pressure
Sodium, Ballast is capable of providing consistent lamp
starting down to -20: degrees fahrenheit. Ballast is fastened to
an easily accessible ballast tray for service convenience.
. Socket is a glazed porcelain medium or mogul base with nickel
plated contacts, rated at5K and 60QV.
Options
. Fixtures available with a variety of options, including photocell,
Quartz restrike, light shield. and fusing. Please consult factory
for custom options.
Listing
. SmartFlood is UL listed, suitable for damp and wet locations.
All fixtures factory tested and prelamped prior to shipment.
c@us
USTED
Adjustable Trunion
217 East 157th Street, Gardena, California 90248
Ptl (310) 512-6480 Fax (310) 512-6486
VIr'WVII. visionairrel ight i 1I'Il9 .COIVI
..
U
CARMEL CENTER
Type: W Mfq:
WALL MOUNT
~B
A
\-T
c
1
)01
Size 2
24"
12"
10"
400w
The Silhouette 2 Sharp Cut~Off Wall Sconce is an HID luminaire suitable
for low glare applications where light spillage is of a concern.
The Housing is available in two sizes. Size One is made of corrosion
resistant precision cast aluminum, Size Two is made of die-formed
aluminum. Both have an exterior decorative reveal.
The Reftector is a sharp cut-off, specular aluminum available in up or down
light and various beam distributions.
The Lens is a diffused tempered glass that is fully gasketed to prevent
moisture and insects.
The Silhouette 2 Wall Sconce utilizes Metal Halide and High Pressure
Sodium lamps, up to 175w. (Compact Fluorescent is available as well
Please consult factory for various wattages.)
Ballast is factory wired and tapped to voltage specifications. All ballasts
are CWA or HPF regulating aula transformers.
F~f mon, llelOlJI(-d irrfarmathn [In rnuu~ljng. wiri.n-y, III ~1Slallalj'1l1l,in~II\..'tlJt~1~, ~I~se wn~ulllactQry Nll'le Ihill. if Poles are !lot O'foor-ed wi1ll ~};Iun~~. p\e~v.- ~~ify the Fi'.o!,/:-jli!'l9 ~i."i:I~il~IJ1':!r1~
lhis dut;Um~1 Ci.mtaim. pfUprie-Lary ifllmmatioo 01 ~5-i0I"18if(l Lighting. llC. An" US~.D; ~h-islnlorm~lio-;1 r~~uiiel \)"Ie wrltler', ~Wl)~al (Il Vi:s.il)~.ai,~ Uqruir;g, Ltt. Il1lrp:~plnQ ""111 our TO\'l pcl,~
0'1 ~Ol1fnllO\,JS imp;o~emen\' lJ.silJn~lre 1t!St:i~oe~ l~e lig~ :Q r;:h!jl'l~l:' ~~ s~[.int-!I1iat1s l'.onlalned ~,ercin w.illioln plln! nndce
;"..In........ '.iiE c~
'Ilmi.~
1.;.:\:::' '1;,,,;,.,,":,+",,,,
Illt;;. ilfLtSl''1 "
J'-~ , ~-, ,ifI7lIJ l
loi,,- :",,,~.,-.=... r.c-':
217 East 157th Street, Gardena, California 90248
Ph (310) 512-6480 Fax (310) 512-6486
'\NV\rW. vis ion a i relii91 h ti ng .com
/
Fax
u
u
" ! ," _-"UT':L;~~,""7~"~lJ ~.. ~"'~~'~1:' ""'~.f'." . .-.7 :::~.~ o"~. .~~~t(.,~
,",C'JY:~OlfCARMEl/ ;:;' ",,,~
." '.,,{ _ .." ~~ .j' ~,;;.-"l,; .. ~ ~..-; If :' i-\. ; or> ~; ~ ~ ;,0; ; ~
, D,ep.!ft;~~m,cn~~~.m~~ S~rvices .
r~'-r .~~w"If, _~-, .,';_, ,':l~ ;((:i~:';.i:.;';'~~ ~~;_ :C"~':;l"'::'.'" ',.I'.,i,/ (.: tl~tJ :}.!
One Civic Square
Carmel, IN 46:J32
(317) 571-2417
FaX: (317) 571-2426
To~ /a-v--I ~.
Fax: /3 go /1/ f'~.5
Phone:
/J. \ \ ,
FrOh1~ ~
Pages~ 2-
Date: tP r /.0 - 02-
R"w~02 Df//!{JLS
cc:
o Urgent 0 Far Review D P.lease Comment 0 Please Reply
o Please Recycle
.,.
D~1tY SfMMQNS PITts & V~HM, IIp
.'
A T TOR N E Y S
v
!l888 Keystone Crossing, Suite 1200 . Indianapolis, Indilma 46240 . (317) 580-4848 telephnne . (317) 58/).4855 facsimile . www.drewrysimmons.com
May 31,2002
. ,-;--l ~'-,,-,.,..
'. '.. ,1 ;~.........
y i' '\
~ "\?\
/-..., \/
(;;-:; RECEIVED \~
~ MAY 31 2002 ~
~5 DOCS ~-...
\(~~ ~~1f
~-~/
Via Hand Delivery
Mr. Jon Dobosiewicz
City of Cannel
Department of Community Services
1 Civic Square
Cannel, Indiana 46032
Re: Camlel Centre West Office Buildings, Docket No. 62-02 D.P.lADLS
Dear Jon:
We have received your review letter dated March 29,2002 regarding the Carmel
Centre West Office Buildings. Please find enclosed a revised ADLS application, revised
site plans, and revised building elevations that address the following comments:
Application:
1. The Development Plan consists of 4 acres. The legal description on the site plan
has been changed to reflect the 4 acres. The applicant owns 2.243 acres where the
first two office building will be located and has obtained the consent of the owner
ofthe adjoining 1. 759 acres to file a Development Plan on their behalf.
2. The first page of the ADLS application has been revised to reflect two office
buildings.
3, A Replat for Block B of West Cannel Center will be filed once it is complete.
Development Plan:
I, The right-of-way dimension along 106th Street has been revised per the
supplementary letter dated April 22, 2002 from the Hamilton County Highway
Department.
2. The setbacks have been revised to reflect the additional right-of way along 106111
Street.
3. The location ofthe casement for the pipeline is shown on the site plans,
4. The number of parking spaces shown on the site plan complies with the
Carmel/Clay Zoning Ordinance.
Mr. Jon Dobosiewicz
May 31, 2002
Page 2 of 2
5. The side yard setback along the east end of the tract has been revised to reflect a
50-foot setback.
6. The landscape plan has been completed. The parking areas are screened.
7. The dimension of tbe parking lot islands has been revised to reflect 9 feet.
8. The plans have been revised to reflect a 5-foot foundation planting around all
buildings.
9. A dumpster detail has been added to the plans that shows an enclosure that is
architecturally compatible with the building.
10. The phrase "Future Development" has been deleted from Sheet 4.
u
u
"
ADLS:
1, The buildings meet the 20-foot minimum height requirement. The building
elevations have been revised to indicate a 1 lJ2 story design on the front and sides
of the buildings.
2. An 8-footoffset has been provided in the middle of each building. Also, a base
has been added to the design of both buildings. The quoins have been removed
from the entrances of both buildings.
3. The location of the mechanical equipment has been added to the site plans.
4. A photometric plan has been added to the set of site plans that shows no more to
than .3 footcandles at all property lines.
5. The light poles wil1 be no taller than 24 feet.
6. Landscaping has been added 011 the landscape plan to the base of the center
identification ground sign.
7. The wall signs bave been changed to individual letters and comply with the size
requirements of the Cannel/Clay Sign Ordinance.
Also, please find enclosed responses to the review letters that we have received to
date. If you have any additional questions regarding this project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration of this matter.
Very Truly Yours
Drewry Simmons Pitts & Vorne1ml, LLP
.~~s
(~~~ . est 106tl1 Properties, LLC
Enclosures
;-..
u
u
Paul G. Reis
preis@tlrewrysimmons.com
DREWRY SIMMONS PITTS & VOR1\rrHJVC1,LP
------.-~-~----------,::~~-:_~~~~-s--~u--~~---- A.{.\}- ~ .l}C1I?~
/J.'~ .'y./ ',/
Y . _ _ if HA1ECtVEOV ~~
. Indianapulis, Indiana 46240 . (317) 511(1.4848 telephone . (3171 ;,l)()-4lbS facsnmle . WW\".dr3Jy~ns.cOfn
o::! DOCS ~
-;;. ~ c"iJ
J @; rT110~>
May 29, 2002
8888 Keystone Crossing, Suite 12()(I
Mr. Steve Cash
Hamilton County Surveyor's Office
One Hamilton County Square, Suite 188
Noblesville, Indiana 46060-2230
Re: Carmel Centre West Office Buildings, 106111 Street and Commerce Drive
Clay Township
Dear Steve:
We have received your review letter dated April 16, 2002 regarding the Carmel
Centre West Office Buildings to be located at the southeast comer of 106tl1 Street and
Commerce Drive in Clay Township. Please find enclosed revised site plans that address
your comments:
1. The project engineer will file the Outlet Permit with your office.
2. The grading plan now indicates that the easternmost part of the site will drain to a
swail on the eastern boundary of the site and the parking lot for Building 3 will
drain to inlets in the parking lot.
3. The existing and future inlets have been properly designated on the plans.
4. There will be some minor grading done on the eastenul10st part of the site and
temporary seeding will be put in place per the request of the Hamilton County
Soil and Conservation District.
If you have any additional que.stions regarding this project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration of this matter.
Very tmly yours,
Drewry Silmnons Pitts & V ornehm, LLP
Enclosure
u
u
DR[ift{l\Y ~L1\1MQt-JS P fITS & Vo RN EJj1\1:,- LLp
A T TOR N E ~ 5
v
8888 Keyslone Crossing, Snile 1200 . Indianapolis, Indianll 46240 . (317) 580-4848 telephone . (317) 580-4855 facsimile . www.c1rewrysimmons.com
Paul G. Reis
prdS@firewry simmons. com
May 29, 2002
Mr. John South, P.E.
Hamilton County Soil and Water Conservation District
11 08 South 9th Street
Noblesville, Indiana 46060-2230
Re: Carmel Centre West Office Buildings, 106th Street and Commerce Drive
Clay Township
Dear Jo1m:
We have received your review letter dated April 16,2002 regarding the Carmel
Centre West Office Buildings to be located at the southeast comer of 106th Street and
Commerce Drive in Clay Township. Please find enclosed revised site plans that address
your comments:
1. The parking lot will be installed prior to starting the building construction.
2. Temporary seeding has been added to phase 2 and 3 of the site.
3. Inlet protection has been added to the plan for the existing two stubs.
4. A note has been added to the demolition plan regarding the silt fence, inlet
protection and construction entrance.
If you have any additional questions regarding tlus project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration of this matter.
Very truly yours,
Drewry Simmons Pitts & V ornehm, LLP
~;s~
Attome~est 106th Properties, LLC
Enclosure
...
.
u
u
DREWRY SrMivtQB~_PITTS_.& VQ~~JT1V[Ttp
A T TOR N E Y S
v
8888 Keystone Crossing, Suite 1200 . Indianapolis, Indiana 46240 . (317) 580-4848 telephone . (317) 580-4855 facsimile . www.drewrysimmons.com
Paul G. Reis
prei.~;irelVrysimnlOlls. com
May 29, 2002
Sharon Prater .
eMS Energy - Panhandle Eastern Pipe Line
P.O. Box 38
Zionsville, Indiana 46077
Re: Carmel Centre West Office Buildings, 106111 Street and Commerce Drive
Clay Township
Dear Sharon
We have received your review letter dated March 27,2002 regarding the Carmel
Centre West Office Buildings to be located at the southeast corner of 106111 Street and
Commerce Drive in Clay Township. Please find enclosed revised site plans that address
your comments:
1. The pipeline will be located and marked in the field before construction.
2. The project engineer has compared the centerline descriptions in the legal
documents for accuracy.
3. The location of Building #3 has been moved to be at least 33 feet from the
pipeline.
4. As the plans indicate, no pipe or culveli is being installed at the south entrance to
the site.
If you have any additional questions regarding this project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration ohhis matter.
Very truly yours,
est 106111 Propeliies, LL C
Enclosure
. ,
u
u
DRfYYRY $IMMQNS PITI~__&YQB.NEHM, LLP
.~_~~_~n'~
A T TOR N ~ Y ~
v
8RS8 Ke~'stonc Crossing, Suite 1200 . Indianapolis, Indiana 46241J . (317) 5S0-4S48 telephone . (317) 580-4855 facsimile . www.drewrysimlIlons.com
Paul G. Reis
preis@drew1)lsimmolls.com
May 29, 2002
Gary Hoyt
Cannel Fire Department
2 Civic Square
Cannel, Indiana 46032
Re: Carmel Centre West Office Buildings, 106th Street and Commerce Drive
Clay Township
Dear Gary:
We have received your review letter dated March 21, 2002 regarding the Cannel
Centre \Vest Office Buildings to be located at the southeast comer of 106t11 Street and
Commerce Drive in Clay Township. Please find enclosed revised site plans that address
your comments:
1. The buildings are not planned to be sprinkled.
2. The buildings are not planned to be sprinlded.
3. The fire hydrant has been located just north of Building 2.
4. The buildings are not planned to have multi-stories or have basements.
5. Our client is willing to meet with you to discuss the location and number of the
Knox boxes.
If you have any additional questions regarding this project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration of this matter.
Very truly yours,
Drevvry Simmons Pitts & V ornehm, LLP
kc .
p~ i.~
Attorney ~est 106t11 Properties, LLC
Enclosure
p.
u
u
D~wRY _SIMM~Y~5J'JII~~J:z:VQBN~liM,JLP-
A T T 0 ~ N E Y 5
v
S888 Keystune Crossing, Suite 1200 . lndinnaplllis, Indiana 46240 . (3]7) SSO-484l:! telephone . (317) 580-4855 rae.simile . www.drcwrvsimmolls.('om
Paul G. Reis
preis@drewrysimmolls.com
May 29,2002
Mr. Steve Broermann
Hamilton County Highway Department
1700 South 10tll Street
Noblesville, Indiana 46060
Re: Carmel Centre West Office Buildings, 106tl1 Street and Commerce Drive
Clay Township
Dear Steve:
We have received your review letters dated March 26,2002 and April 22, 2002
regarding the Cannel Centre West Office Buildings to be located atthe southeast corner
of 106tl1 Street and Commerce Drive in Clay Township. Please find enclosed revised site
plans that address your comments:
1. The right-of-way dimension along 106111 Street has been revised per the
suppLementary letter dated ApriL 22, 2002 from your office.
2. The plans indicate that eastbound lane of 106tl1 Street will be widened to 24 feet to
the east property line and a taper will be provided east of the project boundaries.
3. Adequate roadside drainage has been provided along the south side of the portion
of 106111 Street to be widened.
4. Note 2 in Section 02510 ofthe specifications have been revised to include "The
Hamilton County Highway Department."
5. The curb return radius has been increased to 30' at the north entrance and 45' at
the south entrance.
6. Your comment is duly noted and has been passed along to the project engineer
and the property owner.
7 . Your comment is duly noted and has been passed along to the project engineer
and the property owner.
8. The pavement section has been added to the Construction Details sheet.
t-~ ."
y'
u
o
Mr. Steve Broermann
May 29, 2002
Page 2 of2
If you have any additional questions regarding this project, please do not hesitate to
contact me at 580-4848. Thank you for your time and consideration of this matter.
Very truly yours,
Drewry Simmons Pitts & V orne]1ill, LLP
~c;.
PmLl G. .. eis
Atto for T 1061h Properties, LLC
Enclosure
"
u
u
Johllson, Sue E
From:
Sent:
To:
Cc:
Subject:
Dobosiewicz, Jon C
Friday, May 03, 2002 1 :34 PM
Johnson, Sue E
Lillig, Laurence M; Lawrence, Kelli A; Hollibaugh, Mike P; Hanson, Brian P
Docket Number Assignment - DP/ADLS; West Carmel Center, Block B - Carmel Center West
Office Buildings
Sue Ellen,
Please issue the necessary Docket Number for the West Carmel Center, Block B - Carmel Center West
Office Buildings, DP/ADLS. It will be the following:
402..
lij-02 DP/ADLS $700 + $860 ($700+$35 per acre)
Total Fee:
$1,560
Docket No.lt02 DP/ADLS; West Carmel Center, Block B - Carmel Center West Office Buildings
The applicant seeks Development Plan and ADLS approval to construct an office center. The site is located at
the southeast comer of West I 06th Street and Commerce Drive. The site is zoned B-5/Business and is subject to
the requirements of the US 421/IvIichigan Road Overlay Zone.
Filed by Paul G. Reis of the Reis Law Firm for West 1061h Street Properties, LLC.
Please note the' following:
· This Item was discussed at the Wednesday, April 17, 2002, Technical Advisory Committee meeting.
· Mailed and Published Public Notice needs to occur no later than Friday, May 24,2002.
· Ten (20) Informational Packets must be delivered to Plan Commission Secretary Ramona Hancock no later
than noon, Friday, llme 7, 2002. Failure to submit InfonnationaJ Packets by this time will result in the tabling
of the petition to the Tuesday, July 16, 2002, agenda of the Plan Commission.
. Proof of Notice will need to be received by this Department no later than noon, Monday, June 17, 2002.
Failure to submit Proof of Notice by this time will result in the tabling ofthe petition.
· This Item will appear on the June 18,2002, agenda of the Plan Commission under Public Hearings.
· This Item will also appear on the July 2, 2002, agenda of the Plan Commission Special Studies Committee.
o The petitioner will need to provide fifteen (15) fully filled out Findings-of-Fact sheets for the DP the night of
the meeting at which the Plan Commission takes final action on the request. Please remember to fill out the
Docket No. and date on each findings sheet for the Commission.
S 8CI- 4 8 s;;-'S;'
Please contact Paul G. Reis at 848-4887 (Fax: 84~ 1 D?9) with this information. Once the docket is assigned
please return the file to m~ffice.
h nk "t:t'-..~........--... -S -~-<O~ &;.10
T a s, I .---....-'\... '--'
Jon
~
"".IM.'
~\. p/
J\ .,,"'0' Y'b
,.../
Lp
1
u
u
.1;; :~~': ..-.1'>. ~,-'~r:."'/","_<l';.":-:' l~:~,t:~:.,.. f ..-<...,:I~.J
'. ":c.1nft])j:;'cARMEL':":J'" '..1 .'
. .!;' ~"i.~~~.;- .. -~.' '''', ..'l --~ ~ i;,' !-. 4 - ." P ..-.
.,; ,.eM~m~~'~~~~m~ri:Y.:j;~tyif;~~ ::,.
/::t~.~Li': ;:~r\,~:- ""~ ,~~f;'1~.:t,,\':ji ":~~{~:.t\-: ~';,.L.t,:}: .~.: ;'.,: : "iJ '.:!-." Z:/
One Clvio Square
Carmer, IN 4&:132
(317)571-2417
Fax: (317) 571-2426
To:
'Y-i\",- ~el"
From,- ~N....~
.:L
Fax:
580- '-/8ss
Pages:
Phone:
~~~w.~C~1-1J
Re:
Date:
S~-ac:L
cc:
o Urgent
D For Review D P.lease Comment 0 Please Reply
o Please Recycle
APR 16 '02 09:20PM
P.l/1
Xentoll C. 'Ward, SUrI!eyor
rl'/icmc (jl (') 'i':'f;-8'1.~)5
'[ax (3l7} 7?b.~6.ll\
SHilr l,l';3
()1ll<J{,lItlillDlI COUllty Squllrt
Jillblc51lille, lmlir1iltl ,q.60b,)-:!.130
Aprill,6;~~
;P.,. ,j1~~~; <~~
f1 -'?~ Ii
Re: West Cannel Center, Bloc~B l>o~ <ik J-::;.'
- Cannel Centre West \~~ U' ~ /.)
I have reviewed the plans for this project and have the follo\\'ing comments.Y~~>'/
1. This project is located within the watershed of the Park N orthwestem Drain -
Hamilton Business Park Arm. Therefore1 an Outlet Permit is required.
2. Where are you intending to drain the future Building 3 area?
3. The existing inlet at l06th & Commerce Drive is difficult to see on the plans. Please
identify the existing invert 00 future plans.
4, Will there be any gtading done in the areas marked "future" or will grading be
confined to the phase 1 area?
Mila Slepaya
Mid-States Engineering
If you have any questions or comments, p]eac;e feel free to contact this office at (317)776.
8495.
sinchre ,
../ . -'---C.:;I I
. " ~....~, .,..dl.--6A-----
:.'Steven T. Cash
Plan Reviewer
.,-'
e:..:::.......,-,.
Cc: Carmel Eng.
Carmel DOCS
Co. Hwy.
SCS
7 '1
EROSION AND SEDIMENT CONTR L PLAN
TECHNICAL REVIEW AND COMMENT
Hamilton County Soil and Water Conservation District
1108 South 9th Street, Noblesvillc IN 46060 ~~
Ph- 317-773-1432 or Email at john-south(li}iaswc .-lrr1f
PROJECT NAME:
Carmel Centre West
RECEIVED
APR 11 2002
Mr. Jonathan M fJl; DOCS
Mid-States EngiI1c - ,ing
350 E. New York St~ls.~re 38~
Indianapolis, IN 46204-2~~'4 \
SUBMITTED BY:
The Swiss Group
9245 N. Meridian Street, Su ite 30]
Indianapolis, IN
REVIEWED BY:
.Tohn B. South P.E.
Celiified Professional in Erosion and Sedimcnt Control
PLAN TZEVIEW PROCEDURE: Site Visit Date:
Plan Rcview Date: April 16, 2002
LOCATION: Carmel Centre at 106tl1 and Michigan Road
LEGAL DESCRIPTION: Sec. 7
TOWNSHIP: 17N
RANGE: 3E
CIVIL TOWNSHIP: Clay
SOIL SURVEY MAP SHEET: 55
The technical revieH! and comments are intended to evaluate the completeness of the erosion and sediment control plan for the
project. The erosion and sediment control plan submitted was not reviewed/or the adequacy of the engineering design. All
practices included in the plan, as well as those recOin mended in the comments should be evaluated as to theirfeasibility by a
qualified individual with structural practices designed by a qualified engineer. Theplan has not been reviewedjoriocal, state,
orfederal permits that may be required to proceed with this project Additional information. including design calculations may
he requested to further evaluate the erosion and sediment control plan.
The el"Osion and sediment control plan has been reviewed and it has been determined that the plan:
Satisfies the minimum requirements and intent of 3271AC 15-5 (Rule 5). Notification will be forwarded to the
Indiana Department of Environmental Management.
Refer to the comments section for additional informatiOtl.
X l)oes tlot satisfy the mitlimum requirements and intent of 3271AC 15-5 (Rule 5); deficiencies are noted in the
checklist and in the cOlllments section. Deficiencies constitute potential violations of the rule and must be
adequately addressed for compliance. The information necessary to satisfY fhe deficiencies Illust be submitted:
Proper implementation of the erosion and sediment control plan and inspections of the construction site by the developer or a
representative are necessary to minimize off-site sedimentation. The developer should be aware that unforeseen construction
activities and weather conditions may eflect/he perfrJrmance of a practice or the erosion and sediment control plan. The plan
mus{ be ajlexible document, lvith provisions to modifY or substitute practices as necessary.
Revised 4/97
u
0' PROJECT: Carmel Centre West
Page 2 of 3
Yes No
x IA
x 18
x IC
x 10
X IE
Yes No
x 2A
x 28
x 2C
x 2D
x
x
x
x
x
Yes No
x
x
Yes No
x 4A
x 4B
x 4C
x 4D
x 4E
x
x
x
x
x
u
ARE THE FOLLOWING ITEMS ADEQUATELY ADDRESSED ON THE PLANS?
(AllP{alls MUSI1ttc/wJe Appropriate Legends, Scales, (lml North Arrow)
(Items that are Not AppliC((hle to tlli,,, Project are designated b,y NA)
PROJECT INFORMATION
Project Location Mall (Show project in relation (0 other areas of the county)
Narrative Describing the Nature and Purpose of thc ]'rojeet
Location of Planned and/or Existing Roads, Utilities, Structures, Highways, etc.
Lot and/or Building Locations
Landuse of Adjacent Areas
(ShaH! the Entire Upstream Watershed and Adjacent Areas IVithin 50() Feel of the Property Lmes)
TOPOGRAPHIC, DRAINAGE, AND GENERAL SITE FEATURES
Existing Vegetation (lden/ifjJlmd Delineate)
Location and Name of All Wetlands, Lakes and Water Courses On and Adjacent to the Site
100 Year Floodplains, Floodway Fringes, and Floodways (Note i(None)
Soils Information (lfhydJ'ic soils are present, II is the responsibility of the owner/developer to
investigate the existence o( wetlands and to obtain permits from the appropriate government ogencies)
2E Existing and Planned Contours at an Interval Appropriate to Indicate Drainage Patterns
2F Locations of Specific Points Where Stormwater Uischa rge Will Leave the Site
2G Identify All Receiving Waters (If Discharge is to a Separate Municipal Storm ..';nver, Identify the
Nallle of the Municipal Operator and the Ultimate Neceiving Water)
2H Potential Areas Where Storm water May Enter Groundwater (Note if None)
21 Location of Stormwater System (Include Culverts, Storm Sewers, Channels, and Swales)
LAND DISTURBING ACTIVITIES
3A Location and Approximate Dimensions of All Disturbed Areas [i.e., Construction Limits]
(Areas Where Vegetattve Cover Wal Be Preserved Should be Clearly Des(r;nated)
38 Soil Stockpiles and or Borrow Areas (Show Locations or Note if None)
4F
x
4G
4H
41
4J
4K
EROSION AND SEDIMENT CONTROL MEASURES
Sequence of When Each Measure Will Be Implemented (Relative 10 Earth Disturbing Activities)
Monitoring and Maintenance Guidelines for Each Measure
Perimeter-Sediment Control Measures (Locatioll. Construction Detaif, Dimensions, and Specifications)
Temporary Seeding (Speclfica/ions; Including Seed Mix, Fertilizer, Lime, and Jlvfuich Rate:,)
Temporary Erosion and Sediment Control Measures
(Loco/ion, Cons/rue !ion Detoil, Dimensions. and Specifications)
Permanent Erosion and Sediment Control Measures
(Location, Construction De/iii!, Dimensions, and Specifications)
Storm Drain Inlet Protection (Location, Constmction De/ail, Dimensions, and Specifications)
Stormwater Outlet Protection (Locallon, Construc!ionDetaU, Dimellsions. and Specifications)
Stahle Construction Entrance (Location. Construction Detail, Dimensions, and SpeciJicalions)
Erosion and Sediment Control on Individual Building Lots (SpeciJicatioll,l)
Permanent Seeding (SpeciJications; Including Seed Mix, Fertifizer, Lime, and ,"fll/ch Rate~)
Revised 4 I 97
Sit
..
( ) . ,
ER~ION AND SEDIMENT CONTR~ PLAN
TECHNICAL REVIEW
COrvfM:ENTS
PROJECT:
Carmel Centre West
Page 3 of 3
Note: All erosion 1lf1l1.~ediment control measures shown 0/1 the plans and referenced ill tlll5 repiew must meet tire design
criteria, standard.., alld .\pecificatio/ls outlined in tire "Indialla Handbook for Er()siOI1 Control i/1 Developing Areas" from the
indialla Department of Natural Resources, Division of Soil Conservation or similar Guidlmce Documellt...
4A. Recommend the gravel parking be installed prior starting the building construction.
4D. Temporary or permanent seeding is needed for phase two and phase tlrree on this site. (The rest of
the site.)
4G. Recommend inlet protection for the two existing stubs.
Note: On the demolition plan a statement is needed that requires the silt fence, inlet protection and
construction entrance be installed prior to starting demolition.
Cc: Carmel DOCS
Ha. Co. Surveyor
Ha. Co. Highway
File
.
4
u
u
Johnson, Sue E
From:
Sent:
To:
Subject:
Dobosiewicz, Jon C
Friday, April 12, 2002 3:40 PM
Johnson, Sue E
FW: April 17 Carmel/Clay T AC Agenda
Sue Ellen,
Hope you had a good vacation day (weekend). Please forward the following comments you
received from the District to petitioners.
Thanks,
Jon
see you Wednesday
-----Original Message-----
From: Jay Alley [mailto:Jay@ctrwd.orgJ
Sent: Friday, April 12, 2002 2:08 PM
To: rfarrand@ccs.k12.in.us; AKeeling@ci.carmel.in.us;
CTingley@ci.carmel.in.us; DHill@ci.carmel.in.us;
DPattyn@ci.carmel.in.us; Ghoyt@ci.carmel.in.us; GStahl@ci.carmel.in.us;
JDobosiewicz@ci.carmel.in.us; JKendall@ci.carmel.in.us;
JPFoster@ci.carmel.in.us; KHahn@ci.carmel.in.us;
LLillig@ci.carmel.in.us; MFogarty@ci.carmel.in.us;
MHollibaugh@ci.carmel.in.us; MMCBride@ci.carmel.in.usi
MSnyder@ci.carmel.in.us; PMorrissey@ci.carmel.in.us;
PPace@ci.carmel.in.us; RAuler@ci.carmel.in.us; RHancock@ci.carmel.in.us;
SBrewer@ci.carmel.in.us; SJohnson@ci.carmel.in.us;
slillard@ci.carmel.in.us; WAkers@ci.carmel.in.us; sprater@cmsenergy.com;
sjb@co.hamilton.in.us; stc@co.hamilton.in.us; john-south@iaswcd.org;
heck@iquest.net; jeffry.farmer@timewarnercable.com; tskolak@usps.govi
cshupperd@vectren.com
Cc: Candy Feltner; tstevens@mann-properties.com; preis@reislaw.com;
rlauritsen@SLMACO.com
Subject: Re: April 17 Carmel/Clay TAC Agenda
Hello everyone:
Following are CTRWD comments on the agenda items effecting our sanitary sewers or service
area for the April 17 TAC meeting. Please feel free to copy and distribute this email or
attach it to your meeting minutes. We have also created a new page on our website linked
to the "Construction" page where we have posted all CTRWD TAC comments from 2001 and 2002
meetings held to date. We will continue to add to this page every month so please let
everyone know they can view our comments online now too.
West Carmel Genter Block B
~he plans received by the District only showed a sewer connection for one building;
~bUilding needs to have its own individual connection to the District's sewer so the
will need to be revised to show how the whole site will be served.
each
plans
West Carmel Center Block D
The District has no comments on the re-plat unless it effects the sanitary sewers in
development.
Sed~wick Subdivision
The District has no comments on the plat but will need to review and approve construction
plans when they are completed. The petitioner should contact the District's engineering
1
q
u
u
~;' ~~ +,~. ':r~,I"~\ " ,,:/I~ :r~ ;)~'io_, . ~; ;:,- '~:""~, ~ ~...t. _ 1.~i,
"'~.QIW::OlfQ.M~eL: .:.. ,. ":, - :; ~
:'o~ ",'l" . . .... ~ ~,.! 'j'I'., '\' .
" D;~~~rtm~~~c~~inmu~~!S~rvi~es . .. -
)... ,~..\t~~'~""', .t~, ~ :;;1 :~.!J T ~;..,,;:~ 't..!.":.:ll r' .,,-'tpa; ~ ~.: -.~ . -J--.. l."~;.},J", "'~~l{t
One CivIc Square
Carmel, IN 4€032
(317) 571-2417
Fax: (317) 571H2426
To:
v~~ A~.~
~ 4.'8 - ~Rq ~
From:
~~'iU~
.
c2
1,rS;~ ~
Fax:
Pages:
Phone:
Date:
Ro, J<\i tI.----I ',,> ee,
Qe'M\V. vNT~
o Urgent 0 For Review 0 P.lease Comment
o Please Reply
o Please Recycle
Vl.-~~
~.
.
l0~\
~~ C~~ ~~~ ~
,
, .
Fax
To: \)~I..\l- ~~,~
fIDe ~ c.t t'- Lt ~ ~1
Phone:
u
u
.....I,,~.;"l:, ~..~,~~.\~~..":.~'~~',,:':f. :~.~i.~';-l-",;t'" .:--'~'. ~f':
, ."CITY~OFr CARMEL':":'" >' , "~'
0'. 'of ?'.'.~ ~ ~ : v. ", , ' . . 'i> . "".~. ..~..:..,,' ;;, , . . .
..-: Department dfC~mmUl1mr,S:elvices' .'
:.~I~~~ ~/: : ,i'~~,;-: . .2~;:'<: :J:~'_ ~f.C~;;_ :-'":;: "~~ ~~> "', .' ~;-:?"~":J;' ~:;'7~":~;
One Civic Square
Carmel, IN 4E032
(317) 571.2417
Fax: (31 T) 571-2426
From=
~~
~
~pa~-OeL
Pages:
Date:
~~.. r7"!.lA.L ~~e:rt~ CC~
o Urgent D For Review D PJea.se Comment 0 Please Reply
o Please Recycle
~LS..p..;,~
~~"'.-- ~
-2.'.4 D t:>-. . i'V'> . \}S e'":.." ~ '"'- Q ~
~ '. SD 'Y' 'M.. "\:-. ~ ~
'v
I
~ . ....iI
u
u
City of Carmel
VIA FAX: 848-4899
Original by mail
March 29, 2002
Paul Reis
The Reis Law Finn, LLC
12358 Hancock Street
Carmel, IN 46032
tJ COPr
RE: Carmel Center West Office Buildings: Initial Review
Dear Me Reis:
This letter is in response to the Development Plan and ADLS applications filed with plans on March 21, 3001 noted
above. The following comments need to be addressed and/or plans/applications updated accordingly:
Applicatinn(.~):
1. Several acreages a present within information submitted with the application; 4 acres on face of application,
1.759 acres on the zoning consent, 2.243 acres in legal description (sheet no. 4 of plans). Please clarify.
2. It appears that the Development Plan Application has been filed for the entire tract while the ADLS
application refers to only one building. Is this accurate?
3. A Replat for RlockB of West Carmel Center must be submitted. This will require signature by all owners
of real estate within the Block: Parcel splits of Block B are not currently recognized by the Zoning
Ordinance as legal parcels; This application can be submitted prior to or concurrently ,'lith the
Development Plan Amendment. The Replat application vrill be processed administratively.
nevelopment Plan:
1. Revise all right-of-way per letter from Hamilton County Highway Department dated March 26, 2002.
2. Revise all setbacks according to comment one above.
3. Verify the exact location of the Panhandle Pipeline Easement.
4. The minimum parking requirement is one space per 300 square feet of gross floor area. 157 spaces have
been provided. The minimum parking requirements of98 spaces have been greatly exceeded. Ifnecessary
spaces along 106th Street could be deleted to accommodate the additional right-of-way.
5. The side yard building setback along the east end of the tract is fifty feet. Revise plan.
6. Complete the landscape plan. Note that front and side yard parking areas are to be completely screened
from view.
7. The minimum parking lot island width is nine feet (back of curb to back of curb). Revise all islands
accordingly.
8. The minimum building base planting width for the side of all buildings is 5' in width. Revise area along all
sides of building one and area along the front of buildings two and three.
9. Provide a detail of the trash collection area. Note that it shall be enclosed and architecturally compatible
with the buildings.
10. Provide a connection between the buildings and the sidewalk along 1 06th Street.
11. Delete "Future Development" note on Sheet 4 on plans.
Page 1
ONE CIVIC SQUARE
CARMEL, INDIANA 46032
317/571-2417
t .~..
AD.LS..:.
1.
2.
3.
4.
u
(j
5.
6.
The minimum building height is 20'. This applies to all portions of the buiLding. A void long
uninterrupted roofplanes. I would encourage a two (2)-story design. A 1 :6-story design is required
along the front and sides of the buildings. Modifications are necessary for the proposed building to
meet the minimum specifications.
Additional attention needs to be paid toward section 23C.9 regarding Architectural Design
Requirements. The ordinance requires buildings of greater than 90' in width to provide offsets of not
less than 8' in depth, revise building footprint. The building has no defmed base, revise elevation.
Material changes are not permitted aLong a vertical line (Section 23C.9.D). The Quoins and limestone
accents do not conform to this requirement, revise elevations.
\\There is mechanical equipment to be located?
Submit lighting plan to illustrate property lines and meet maximum of 0.3 footcandles at all property
lines.
Note that the maximum light pole height is 24 feet per Section 23C.12.B.
All signage will require approval by the Plan Commission. The proposed ground sign may be a
maximum of 60 square feet in area and 6 feet tall. The sign also requires landscaping:
Based on the setbacks and building frontage a sign on the building may be either a maximum of 30 or
35 square feet in area depending on the setback of the sign from the right-of-way. Ifall signs are
proposed to be 33.6875 square feet in area a variance will be required. .
7.
If you have any questions or if I may be of assistance please do not hesitate to call. The docket number will be issued
upon receipt of additional information necessary to complete the application. T AC will review the plans at their
Aprill iJJ. meeting. However, due to the changes necessary to bring the proposal into conformance with the
Ordinance it may be necessary to schedule an additional hearing at T AC in May.
Sincerely,
Jon C. Dobosiewicz
Planning Administrator
<;u. VJ#
Carmel Center Wesl-Reviewl.rtf
Page 2
ONE CIViC SQUARE
CARMEL, INDL\NA 46032
317 /571-2417
I
u
u
Panhandle Eastern Pipe Line
An International Energy Company
p. 0, Box 38
llOnsville IN 46077
Tel: 317 873 2410
Mr. Mark Monroe
The Reis Law Firm, LLC
12358 Hancock Street
Carmel, IN 46032
-\
I I
:';:1
1__
,
- " ,:/
~~- '-~., /<;>
,.~/ ,'-..:..----,-1(-::\ ..>/
~'"-----'~-'~- --~
fff.,r:fl!~
'. ~ ,,-;,1,':-' tn,,,,,?;)
rfAR -, "i!;f[)
".-, 28 ')'
cJIOt."
DOCS
,
, ,').,
- "
"~
March 27, 2002
RE: Carmel Centre West Project
File No. 2082/1
Hamilton County, Indiana
Dear Mark:
Pursuant our telephone conversation on 3-26-02, enclosed is a copy of Panhandle Eastern
Pipe Line Company's map showing the approximate location of our two 30" high
pressure natural gas transmission pipelines crossing the referenced property.
'(
The northerly pipeline (400 line) was secured by condemnation, Cause No. 8544, Book
109, Page 225 in the Tipton County Circuit Court. The permanent easement and right-of-
way is a strip of land 66 feet in width, being 16' on the northwest side and 50' on the
southeast side ofthe pipeline. The southerly pipeline on this parcel (300 line) was
defined by Modification of Right-of-Way Grants dated 3-31-58. The easement and right-
of-way is a strip of land 100 feet in width, being 50' each side of the pipeline (See page
3, paragraph B).
In response to plans dated March 13,2002, Panhandle would request the tollowing prior
to any approval: 1. Field locate, and mark the pipelines across subject property; 2.
Illustrate the location afthe pipelines and compare the centerline descriptions in the legal
docUlllents for accuracy.
The plans illustrate a future building 3 of which a comer appears within the pipeline
easement or at the easement boundary. For the safety and integrity of the pipelines, the
company would appreciate your consideration by adjusting the building location to a
minimum distance of33' measured at right angles from the pipeline. It appears that
building 1 is at least 50' from the centerline of pipe, which is a more acceptable design
adjacent our facilities.
A more detailed drawing of the south entrance into the site is needed for review.' Is a
culvert being installed at this entrance and will there be a ditch cut over the pipelines?
u
u
,
General restrictions and requirements are enclosed to assist in the planning of the
proposed development..
Please call me at 317-733-3213 should additional information be required.
Sincerely,
QllfiNrf GY~
Sfuron J. Prater
Sf. R/W Representative
Enc.
CC: Jonathan P. Moen, Mid-States Engineering
Jon Dobosiewicz, City of Carmel
File
u
u
.-
."
PANHANDLE EASTERN PIPE UNE COMPANY
A Un" of PlJi1/rJlldle E;asftYIt Corpnlloo
~I
400
T
~l!
~OO
~ IT
100
i I II
200
II
:~ :::!
30' t
I
I II :
? :SO'
&
I 1 11 1 ~
~G'
13)11 [ ;,;.
24' ~ 11 'i
~
N~T Ttl ~E U'~;;~D IN Uf~U Of &URIJ'E'(
i
IO~
zoo
3QO
40~
~L
$
5L
9
6L
11.2
6L3
41.2
612
5U
4U
T I 7 N R 3 E HAM I L TON CO., I NO I ANA
--
L. f/-jJQ .
3o()
L- i j.) e.-
-------
I ~06' TO
SECn ON CORNEA
--
I
\
C.
-94
R VI 10/'11 - O'ESCRif'rr N If., . No. or BOOJ:. lli PiC: ~.s
E.NTIR QOP OI"S-TRIB TIOill
SCAL.E IN FE[T
300
300
EOD
ZIONSVll.LE
Zh1~i?TA .fl~1 2800
r-+q: '* r I I I I (
4
GATE 2
I l@i
u
u
.-1 OHsEN~
Panhandle Eastern Pipe Line
An International Energy Company
p.o. Box 38
Ziansville IN 46077
Tel: 317 873 2410
GENERAL ~QUIREMENTS FOR CONSTRUCTION IN THE VlCINITY OF
PANHANDLE EASTERN PIPELINE COMPANY'S PIPELINE(S) OR
EASEMENT
CONTACT PANHANDLE EASTERN ROW DEPARTMENT TO DETERM:INE
THE PIPELIl'I""E(S) EASEMENT
The followin~ lluidelines present the 2eneral requirements for construction in the
viCinity of Pan.h and Ie Eastern Pipe Line Company's (herein referred to as
Company) pipeline or easement. Specific circumstances may neceSsitate additional
considerations.
GENERAL REQUIREMENTS:
No permanent structures of any kind shall be permitted, placed or erected within the
easement parcel, including storm drains, catch basins, water impoundments, fire
hydrants, sign boards, supports, brace poles, telephone and power line poles, lighting
poles, decks, fences, railroad tracks, garages, buildings, trailers, septic tanks, leach fields,
swimming pools, berms.
All roads, driveways, streets, sidewalks, alley or cUrbing shallcross the pipeline(s) at an
angle near to 90 degrees as practical extending the width of the easement parceL A
minimum. cover of36" of cover between the top of the pipeline(s) and bottom of the
pavement must be maintained across the entire width of the easement parcel. No portion
of the easement parcel shall be utilized for the parking of vehicle"s, and no impervious
type pavement in connection "\Vith the establishment or use of any vehicular parking area
shall be placed over or within the easement parcel. Proposed street intersections, cul de
sacs, drainage and utility easements shall be designed outside the easement parcel.
All utilities shall be constructed below the pipeline(s) with a minimum of 18" of
clearance. Additional separation may be required in marshy areas or other areas where
the 18" of clearanc~ would have a potential for future problems. Telephone, electric, and
plastic gas lines under 4" shall be .installed under the pipeline( s) where practical, and
encased in conduit. Ifunderground cables are over 600 volts, the cable must cross below
the pipeline(s), placed in non-metallic rigid conduit encased in concrete that has been
colored in red dye, or covered with bags of sakrete, extending across the confines of the
easement parcel.
Storm drains must be solid impervious material extending the width of the easement
parceL No foreign.structures, appurtenances or related fittings will be permitted within
the easement parcel.
u
u
No trees,sbrubs, or evergreens shall be permitted, placed or planted anywhere on the
easement parcel
No cover or any lateral or subjacent support be removed. from said pipeline(s) except
temporarily and as an incident to the construction of utilitymstallatians, streets
sidewalks, driveway, road, ditch or swale, alley or curbing authorized to be placed across
the easement parcel. Prior approval by the company must be obtained for either removal
or addition of additional cover over the pipeline easement parcel.
DRAINAGE SWALESIW ATERW AYSIDITCHES:
Proposed ditches or waterways must cross the pipeline at near or right angles across the
easement parceL A minlmum cover of36" between'the top ofpipeline(s) and bottom of
ditch or waterway must be maintained.
No drainage swales or reductions in grade are permitted on the pipeline easement.
Limited additional fill may be deposited. Proposed grades shall not restrict the
Company's access to the right-of-way easement, cause ponding of surface water on the
easement, nor redirect the flow afwater, which could generate any amount of erosio'n on
or near the easement. Ditches, waterways or swales will riot be permitted to run parallel
and within the easement parcel. '
TERRACES:
No cover should be removed untillocatian of facility crossing and depth of pipeline can
be determined. If it is necessary to remove cover within the right-ai-way confines, the
remaining cover of36" must be maintained. Prior approval from the company must be
o btamed.
EARTHWORK:
The adding of cover may be permitted, if necessary, but the depth of cover should not
exceed 7' from the top of the pipeline to final grade. Prior approval from the company
must be obtained.
BLASTING:
No blasting will be permitted within the pipeline(s) easement. The Company must be
advised of any blasting proposed within 500' of its facilities. The party responsible tor
the blasting must submit detailed plans to allow far evaluation and ta make arrangements
for witnessing the blasting operations.
u
...u
DRA. WINGS:
The pipeline( s) depth and location must be incorporated :into the proposed development
site plan and accurately scaled on to actual construction prints.' All construction prints
must contain th~. following on each sheet showing the pipeline:
DANGER! USE EXCESSIVE CAUTION! Panhandle Eastern Pipe 'Line Company
high-pressure natural." gas pipelines. Panhandle must be notified directly at 317-873 - 2410
and through the Indiana Untierground Plant Protection Se:rv;ice at 1-800-382-5544 with
two full working days notice of any activity within its easement and have a representative
present during any excavation over or adjacent to its pipelines.
Upon review of this information and incorporation of all applicable requirements, two (2)
complete sets of design drawings must be submitted to the. Company for review by the
Company's technical staff The Company must pre-approve development desi~.
construction and any modifications plans involving companifacilities.
EXCAVATION:
When necessary to excavate near company pipeline(s), a Company repre~entative must
be on site to witness the excavation, to locate the pipefuies, and to detenftine the depth of
cover before and during the excavation. The contractor must not perform any excavation,
crossing, backfilling or other cnnstruction operations unless the Company representative
is on site who shall have full authority to stop the work if it is being performed in an
illlSafe manner.
Excavation with a third party backhoe or other mechanical equipment shall not be
permitted within the Company's easement until the excavation procedure has been
reviewed and approved by a company representative. As a minimum, the excavation
procedure will require the contractor's backhoe to have a plate welded over the
teeth of the backhoe bucket and to have the side cutters removed prior to
excavatiOb.
VEmCULAR CROSSiNGS:
Heavy equipment crossings should be stopped until calculations can be made too
determine the effects of the external loads on the stress of the pipeline(s). Immediate or
long-term damage to the pipeline(s) may occur as a result ,of external stresses associated
wnh crossing buried pipeline(s}by heavy _equipment. The developer.or .c.ontractor must
discuss this matter with the company and provide to the company's technical staff the
total loaded axle weight for each piece of heavy equipment. Load .calculations .on.the
pipelines will be evaluated to determine the combined stresses on the pipelines and if any
tempOIary proiectiv.e measures must be taken. If stresses :ar:e not acceptable, necessary
means to distribute the load such as matting or timbers will be required prior to
equipment crossings.
"
; '.' .~.
u
u
NOTIFICATION:
The Company shall be given at least three working days advance notice prior to the
actual commencement of any work or excavation over or near its pipeline(s) The
company will locate ~ts pipeline(s) and have a field representative present during
,excavationocco.nstrl1ctioo.activities. The , company representative will be at no charge to
.the contractor or .dev.elo.per.
Developers, contractors, utility companies and landowners must comply with the
provisions .of the State .Qne-cal1r.cgtilations ,relating, to .excavation and.demolition wOIk ,in
the vicinity of underground .mcilities.
INDIANA PUBLIC LA W, 18-69-1990, requires anyone planning to excavate must
notifY the Indiana Underground Plant Protection Service with,two (2) full.wo.rkingdays
notice, toll free at 1-800-382-5544 prior to the commencement of said excavation.
To:
Address:
City, ST,
Zip:
Attention:
Re:
Mail 0
u
u
Transmittal
Mid-States Engineering
350 East New York Street
Indianapolis, IN 46204
Phone: 317 634-6434
Department of Community Services
Date: 3/25/2002
One Civic Square
Carmel, IN 46032
Jon Dobosiewicz
Project: Cannel Centre West
Drainage Report
Job No.: 111-1376
Messenger l6J
Express D
Pick-Up 0
We are sending herewith:
Check
l6J
o
o
o
o
D
o
D
D
D
o
[8J
Dcscri tion
Co ies
"';/.
Drainage Report
~
10)(5':;";>("=0" fir;:,
IfliISI""Ie:.;IW;,,,,;,ij
MAR 26 2002
DOCS
',:~\
IJ:
" .
-,
/'- J
, , /
/
'-"
The information as per your request
Please review and respond
See remarks below
Remarks: Enclosed is the drainage report for the above referenced project. Construction plans have been sent to your attention
separately.
If you have questions, please contact me at 616-2063. Thank you.
cc:
From: Mila Slepaya, Project Engineer
o Correspondence
03/26/02 15:25 FAX
u
HAMILTON CO HWY, -OJ'; Carmel DOCD
U
141 0011001
HAMILTON COUNTY
HIGHWAY DEPARTMENT
March 26, 2002
Mr. Michael L. DeBoy
Mid-States Engineering
970 Logan Street, SLljte 202
Noblesville. Indiana 46060
RE: Carmel Centre West
Constructron Plans
S of 1061" Street I E of Commerce Drive
Clay Township
Dear Mr. De!:!oy:
This letter serves to acknowledge receipt of a transmittal received March 21, 2002, containing the
plans for the above-mentioned project. After reviewing the plans the Highway Department has the
following comments:
1. In accordance wIth the Hamilton County Thoroughfare Plan, additional right of way is
required at the intersection of 1oa1h Street and Commerce Drive. On Commerce Drjve, the
right of way from the intersection to a point 500' to the south [s a 60' half. From that point to
the southern property line the right of way is 45'. On 1 061n Street, the right of way from the
intersection to a point 500' to the east is a 65' half, From that point to the eastern property
line the right of way is a 50' half. A 50' triangular cut is also needed at the intersection,
connecting the right of way for the perimeter streets.
2. As a part of this project, the eastbound lane of 1061" Street will need to be widened to a total
width of 24', The widening should extend to the east property line. A taper will need to be
striped to transition the traffic back to one lane. east 01 the prOject.
3. Adequate roadside drainage wilJ need to be provided along the widened section of 10Sth
Street.
4. Please correct Note 2 In Section 02510 of the Specifications to read Hamilton Coonty
Highway Department.
5. The curb retum radius at the north entrance should be increased to 30' and 45' at the south
entrance.
6. Road cuts will not be issued for any installation of utilities. All installation/extension must be
done through pu&h1bore_ Permits will be required of aU work to be perl'ormed within the right
of way.
7_ Commercial Drive Permits will be required for this. pl'oject, please contact Mr. Rob Chadwell,
Permit Inspector, for the necessary forms and information.
a. . The pavement section for aU work done within the right of way shall consist of a 12" stone
baSil, 5" of binder and 1" of surface.
If you have any questions or comments concerning this letter, please feel free to contact me at
anytime.
Sincerely,
!t..f~~-
4~~n J. Broermann
Staff Engineer
Jon Oobosiewicz
Steve Cash
Rob Chadwell
1100 South 101M Str\:et
NobJcsville, In. 46060
CC:
G:\USEFi!S\S8\02T AC\01-1 &<121 OOa"dcommeroe.~
www.co.hDmiltonJn...u..5
Office (317) 173.7770
Fax (317) 776-9814
u
THE REIS lAW F~RMp llC
Mr. 10n C. Dobosiewicz
Department of Community Services
City of Carmel
1 Civic Square
Carmel, Indiana 46032
u
March 25, 2002
/\\~., (I. .
u(!~ \. y;:\ll.'N'fi
1,....,;lv.!..J..Iv~~_.-"" ,jti'f.,:..).,,j1"'k
"'" \ c-J"f"
~r ".) j.".-;j-r'~""',,",
Writer's Direct Dial
(317) 848-4887
mmonroe@reislaw.com
RE: Development Plan and ADLS Applications
West 106th Properties, LLC - Southeast Comer of 1061h Street and Commerce Drive
Our File Number: 2082/1
Dear Jon:
I am enclosing for the file on the above-referenced malter, the zoning consent of: the Admiral
Holdings, LLC, 421 Realty Co. and R.P. Wurster Irevvocablc Trust. Thcsc busmess entities own the
eastern-most part of the Real Estatc that is the subJcct of the Development Plan petition.
To the extent that you have any questions or if we can be of any further assistance to you in
this matter, please do not hesitate to contact me.
Enclosure
1:\20~2\1 \Ltr\Dobosiewicz 3-25-02.doc
Very Tnlly Yours,
THE REIS LAW FIRM, LLC
--wr~~ Wt~
Mark T. Monroe, AICP
Land Use Planner
1,' 4>>
-;'-";;- '(0~ . w
1:7' rf11" yy
~~~
Q ~ ~,*i\\
~ ~ 'fg
(f' ~
p
.......
~)
./-- !
.~/
12358 HANCOCK STREET 0 CARMEL, IN 46032 .317-848-4885 0 FAX 317-848-4899 0 FIRMraREISLAW.COM
\:- -
,>'
l]j.~L.
L\-L.
L.LL.
.'';''.. :"C' u,
- -.. .
.v,_, '. _ '. ~ ,. _". .'
";:. . - ~,- .
"_ h""<;-.:'-'-_~'"
, -
u
\
u
TH E REIS LAW FIRM, LLC
Wnter's Direct Dial
(317) 848-4886
preis@relslaw.com
March 20, 2002
, "C'_"
"A
"'-'( /
..ttS '. ~ "
~t~~~ ."~
Alii J) GAi;7,"'i'?'~ \-;:-. "
'Ilil{ ":/lYlr '~J-;
,pI ''<~
DoC's <'47;
'.....
',- #~
"7,,,,)\ '
. ---L...!-I'~
Mr. Steve Cash
Hamilton County Surveyor's Office
One Hamilton Square, Suite 146
Hamilton County Judicial Center
Noblesville, IN 46060
RE: Cannel Centre West ProJcct
Southeast corner of 106110 Street and Commerce Drive
Our File Number: 2082/1
Dear Steve:
On March 21, 2002, we will file wllh the City of Carmel Department of Community Services,
on behalf of West l06lh Properties, LLC, ADLS and Dcvelopmcnt Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of I06th Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17,2002 agenda of the Technical
Advisory Committee and the agenda of the Cannel/Clay Plan CommiSSIOn for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regarding this matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Very truly yours,
THE RErs LAW FIRM, LLC
Enclosure
cc: Jon Dobosiewicz, City of Cam1el
"I ;: ~ ~j ~~ ,II!-\ i~ l,~ L: .~_: V~ ~~ T i~ E: r: T
(, i-\ Ft. H E ~ _, I ~.~, .~. ~" l) ,~ ,::
..'~ .~ <? - r~ r; :-\ . ,~. ~ e ~:I
~~ ,,:~ \ .;.! !,' !.~ 4 L; - ;" ,;:j ~;. <.
:., I 1-' :"i c.) f" E :: _. ,,'.
..
u
u
THE REIS LAW F1RMt LLC
Writer's Direct Dial
(317) 848-4886
prcis@rcislaw.com
March 20, 2002
Mr. JOM South
Hamilton County Soil & Water Conservation District
1108 South 9th Street
NoblcsvllIc, IN 46060
RE: Carmel Centre West Project
Southeast comer of 106th Street and Commerce Drive
Our Ftle Number: 2082/1
Dear .John:
On March 2 L, 2002, we wtll file with the City of Cannel Department of Community Services,
on behalf of West 106111 Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of 106111 Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review_
We are anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward 'any comments you ha veafter your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you ha ve any questions regarding this matter In the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your eooperation and
assistance.
Very truly yours,
THE REIS LAW FIRM, LLC
~;'~
Attomey~est I06th Properties, LLC
Enclosure
cc: Jon Doboslewicz, City of Carmel
) :.:' ;'j ~) n H~' l,~ C, U L !.' ::J T ~~ F '= .,;-
!:~ /j: I~~ ~II, E i.., I I i'.,i j, f:, I} :' ~,
~ ~ 'i i' .-~) .~- ej - :.'( ,~~ ~2 ~~
1 \ ':"'
, I
i'~ .r~, F. "'.~ ,;r. 1./
1'H(ri ~,:?ij;',
;-,',-,,-'.
w
u
THE REI 5 LAW FIR M. L L C
Writer's Direct Dial
(317) 848-4886
prei~@reislaw, com
March 20, 2002
Mr. Gary Hoyt
Office of Fire Chief, Fire Station #1
Two Civic Square
Carmel, IN 46032
RE: Carmel Centre West Project
Southeast comer of 106th Street and Commerce Drive
Our File Number: 2082/1
Dear Gary:
On March 21, 2002, we will file with the City of Carmel Department of Commumty Services,
on behalf of West I06lh Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of 106th Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the CannellClay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address hstcd above.
If you have any questions regarding this matter in the mean time, please feel free to contact
mt: at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Vcry tndy yours,
THE REIS LAW FIRM, LLC
~o
't:!:
l )
Pa ... . Reis
A ttomey for est 106,h Properties, LLC
Enclosure
cc: Jon Doboslewicz, City of Carmel
1 ~~ J 5 ~j H!J, !-~ '::. 0 C 1"\ ~j r r-~ E E r
r. 1\ R !il E L. l:~ L :;, :J :'" ;,
-.~ 7 'f~~ ,~, ',:J, T,_ r'~i~: g l~
l' 1..\: ~\ :~ -1 '/ -. e I'~' 8 .. i'l, [,~ )1 r"
~~ 1 h I i~ II:j .-< i,' I ~- L ;.':. 1~;.1 L-~ 11
u
u
THE R E IS LAW FIR M. L L C
Wrill:r's Direct Dial
(317) 848-4886
prels@reislaw,com
March 20, 2002
Mr. L. Joe Cook
Hamilton County Sheriff Dept.
18100 Cumberland Road
Noblesville, IN 46060
RE: Carmel Centre West Project
Southeast corner of 106th Street and Commerce Drive
Our File Number: 2082/1
Dear Mr. Cook:
On March 2\, 2002, we will file with the City of Cannel Department of Community Services,
on hehalf of West 106th Properties, LLC, ADLS and Development Plan Applications and
wrresponding plans for the professional and general office buildings located at the southeast comer
of 106'" Street and Commerce Drive in Clay Township, Hamilton County, Indiana, Enclosed herewith
are the site construction drawings for your review.
Weare anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at ollr
office address listed above.
If you have any questions regarding this matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperatlon and
assistance.
Very truly yours,
THE REIS LAW FTRM, LLC
~4~~
p~.-~0( ..
Attomey for West 106th Properties, LLC
Enclosure
cc: Jon Dobosiewicz, City of Carmel
Z :! 'i:3 H." i.; C (j c: 1\ c, T Ii ~ "- r
CI.:. R!vI t:: I.. !I, I,;' U '] ,/
:11 '1- 8:.8-lUlIS
F l\ .:; . ~ i 7 E~ 4 ~~ - [1- ~3 Sl i
~ i f.' .,'< r3 f; [ 1 :~, L .\ \1'.,- ': ',,",
u
u
nf~ _ TH E REIS LAW FI RM, LLC
. ,~"~'f:jar,r~~-~~ .
I
Writer's Direct Dial
(317) 848-4886
preis@rcislaw.com
March 20, 2002
Mr. Steve Broennann
Hamilton County Engineering/Hamilton County Highway
1700 South Tenth Street
Noblesville, IN 46060
RE: Cannel Centre West Project
Southeast comer of 106lh Street and Commerce Drive
Our File Number: 2082/1
Dear Steve:
On March 21, 2002, we will file with the City of Cannel Department of Community Services,
on behalf of West 1061h Properties, LLC, ADLS and Development Plan ApplicatIOns and
corresponding plans for the professional and general office buildmgs located at the southeast comer
of 106\11 Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipatinghaving this project placed 00 the Aprill7, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/ClayPlan Commission for May 2\, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regarding this matter in the mean time, please feel free to contact
me al g48-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance
Very truly yours,
THE REIS LAW FIRM, LLC
pa~~
Attorney ror West 106111 PropertIes, LLC
Enclosure
cc: Jon Doboslewlcz, City of Cannel
I 2 3 .) (\ H.~ 1\ r. 0 C!\ S r !~, l= F:,'
C A ,~ IVI !: I.. < ! r~ ,~t.1 C :',~ _'.~
3.i'l..hl:~{ Lb~3:c:;
r- )'. ,r:_ 3'~ '? ,~; J :J, - :~ r.~ ':.~ '.'
r i ~1- 1,!t:2 n':: I r.~. I~ c!..~_ I.:_!. ;__, .'1 Li
u
u
THE REIS LAW FIRM, LLC
Writer's Direct Dial
(J 17) 848-4886
preis@rcislaw.com
March 20, 2002
Mr. BIll Akers
Carmel Communications
31 First Avenue NW
Carmel, rN 46032
RE: Carmel Centre West Project
Southeast comer of 10611l Street and Commerce Drive
Our File Number: 2082/1
Dear Bill:
On March 21, 2002, we will file with the City of Cannel Department of Community Services,
on behalf of West ] 06th Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings locaLed at the southeast comer
of ] 06th SLreet and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawmgs for your reVIew.
We arc anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regardmg thiS matter m the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Very truly yours,
THE RE1S LAW FIRM, LLC
pa~
Attorney for West l06th Properties, LLC
Enclosure
cc: Jon Dobosiewic7., Ci t:y of Carmel
; ~2 ,-~~ :) b i-! ,L I" j.~- I.} C I'~~ S 'r 1\ E f T~'
c j~ H H E ,__ J i ~-..! -/. t; 1) ~~ 2
'~\ -~ '7 .. B l! f: ~ ~;. 8 C '~
i:. r'-~, X ,:J '1- i - r~ /~ 2' - ~ 8 S' :/
j" : j-( il'; ,-;- F~, r~;" ,~: Ii.' ~ .~. H
u
u
THE REIS LAW FIRM, LLC
Writer's Direct Dial
(317) 848-4886
preis@rcislaw.cum
March 20, 2002
Mr Jeff Rice
Ameritech
5858 North College Avenue
indianapolis, IN 46220
RE: Cannel Centre West Project
Southeast comer of 106lh Street and Commerce Drive
Our FlIe Number: 2082/1
Dear Mr. Rice:
On March 21, 2002, we will file with the City of Carmel Department of Community Services,
on behalf of West 106th Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the profcsslOnal and general office buildings located at the southeast comer
of 106111 Street and Commerce Drive in Clay Township, Hamilton County, [ndiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21,2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regarding tlus matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Very truly yours,
THE REfS LAW FIRM, LLC
p~~
Attorney for West 106\11 Properties, LLC
Enclosure
cc: Jon Dobosiewicl, City of Carmel
"' '2 3 :) H H '~'. !\i C CI C 1'\. S -I R E t_ -I
l~ fj, 11 !'.'I r: L, i hi .4 t, ~~ J :-~
-,~ ': '} 8 li- ~~~ - I"~ f, c ;:~
F {....!I,: :~ 1 7 :?i, ~J ,~:3 {} s:
f ! i-' ',,1 if.i R ~: ~ :~:; ~. p'J, \1 i i"~ r; ~.J;
u
u
THE REIS LAW FIRt"i, LLC
Writer's Direct Dial
(317) 848-4886
preis@reislaw.com
March 20, 2002
Ms. Pam Waggoner
lndtanapohs 'Vater Company
P.O. Box 1220 .
Indianapolis, rN 46206
RE: Carmel Centre West Project
Southeast comer ofl061h Street and Commerce Drive
Our File Number: 2082/1
Dear Ms. Waggoner:
On March 21, 2002, we will file with the City of Carmel Department of Community Services,
on behalf of West 106lh Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of 106111 Street and Conunerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17,2002 agenda of the Technical
Advi sory Committee and the agetida of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regardIng this matter 10 the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance_
Very truly yours,
THE REIS LAW FIRM, LLC
~~
Attorney ~cst 1061h Properties, LLC
Enclosure
cc: Jon Dobosiewicz, City ofCanncl
i 2 J ~) FJ H i\ !~ C 0 C; f\ ~;r H [ t;
C L !-\!vj t L, I ~.! ,,:) lJ J i
3 "\ '/ - ;8 l, 8 .- '~i 8 8 I.l
;:-,iJ/~ ,~-i -/-~~~~ 8n"'IE'~~':j
~-::! F~ 1\1, rd ~.~ r:, ~., I. ,:'.V,_I L' t-,I ;t~
u
u
THE REIS LAW FI!iM~ LLC
Writer's Direct Dial
(317) 848A886
preis@rcislaw_com
March 20, 2002
To Whom It May Concern
Carmel/Clay Parks Department
1055 Third Avenue SW
Carmel, TN 46032
RE: Carmel Centre. West Project
Southeast corner of 1061h Street and Commerce Drive
Our File Number: 208211
Dear Sir or Madam:
On March 21, 2002, we- will file with the City of Carmel Department of Community Services,
on behalf of West 1061h Properties, LLC, ADLS and Development Plan Applications ami
corresponding plans for the professional and general office buildings located at the southeast corner
of 1061h Street and Commerce Drive in Clay TO'W11ship, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
Weare anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Momoe at our
office address listed above.
If you have any questions regarding this matter In the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848A887. Thank you very much for your cooperation and
assistance_
Very truly yOIJrs,
TilE REIS LAW F JRM, LLC
est 106lh Properties, LLC
Enclosure
ce: Jon Dobosiewicz, City of Carmel
12358 Hph'IJiLI( STRICU
U\ R 1'.\ E L, Ii,
r , ,.' ~ ,
I~ ~', '..: ,.:' t.
J '1 "1 -. 2 /1 8 .. ~ FJ f~ .J
F '/~ X J ~ ',: - E, l 3 ... [I 8 S' -:1'
~,.:..: ~ h' i.,~ Iri r::" ~' ! ~~:! .I~. \/',1 . L 1"1
u
u
THE REIS LAW FIRM, LLC
Writer's Direct Dial
(317) 848-4886
prcis@rcislaw.com
March 20, 2002
Mr. Chuck Shupperd
Indiana Gas Co.
P.O. Box 1700
Noblesvllle, IN 46060
RE: Carmel Centre West Project
Southeast cornet of 1061h Street and Commerce Dri ve
Our File Number: 2082/1
Dcar Chuck:
On March 21, 2002, we will file with the City of Cannel Department of Community Services,
on behaLf of West 106th Properties, LLC, ADLS and Development Plan ApplicatlOns and
corresponding plans for the professional and general office bUlldings located at the southeast comer
of I06th Street and Com1l1erce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the sitt: construction drawings for your review.
Weare anticipating having this proj ect placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Camel/Clay Plan Commission for May 21, 2002. Please
fOf\vard any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If YOLl have any questions regarding this matter in the mean time, please feel tree to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance
Very truly yours,
THE REIS LAW FIRM, LLC
p~~
Attorney for West 106tl1 Properties, LLC
Ene losure
ce: Jon DoboSJcwicz, City of Camle!
"1 :~. "1 J ~:. Ii l':_ I'~ r: G [. ~{ '3 T ! ~ E L~, -:
C h F~ ].4 E i_ Ii:'.. ,[~,~ U ~) .(
3 '! '/ iJ i.-c ~ - '~rJ.9 ~
\~. _~'jj [~'l.H'~..~5
it::' n \~-:: J~~ 1:_ ~ :~: l_ '-', 'I)'.' ~_' ,. ~ i..:
u
u
THE REIS LAW FIRM, LLC
Writer's Direct Dial
(3] 7) 848-4886
prcis@n.:islaw.com
March 20, 2002
Mr. Ron Morris
Indianapolis Power & Light Co.
3600 N. Arlington Avenue
Indianapolis, IN 46218
RE: Carmel Centre West Project
Southeast comer of 1061h Street and Commerce Drive
Our File Number: 2082/1
Dear Mr. Morris:
On March 21, 2002, we will tile with the City of Cannel Department of Community Services,
on behalf of West 1061h Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast corner
of I06lb Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17,2002 agenda of the Technical
Advisory Committee and the agenda of the Cannel/Clay Plan Commission fOT May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address hsted above.
If you have any questions regarding this matter in the mean time, please feel free to contact
mc at 848-4886, or Mark Monroe at 848-4887. Thank you very mllch for your cooperation and
assistance.
Very truly yours,
THE REfS LAW FIRM, LLC
~~
Attorney for West 1061h Properties, LLC
Enclosure
cc: Jon Dobosiewlcz, City of Carmel
'! ':: 'J:~ g H A h C (I C I< ~j 1 :.~ E E T
C /.~ :~ !vl E L. ~ I-,J I~ G 0 3 ?
:3 '[ ",' ". !j /~ f~ .. ~. 113 ~ i,')
f /J. ,~~ ':~.\? - ~) ~ ? - /l B Ii 1}
r, I ,l~_' H I~.~ ;-1 [ ! ::: ,. /''c \t\/ (; 1 !-,".
u
u
THE REIS LAW FIRM, LLC
Wnter's Direct Dial
(317) 848-4886
pn:is@reislaw.com
March 20, 2002
Mr. Scott Brewer
Department of Community Services
City of Carmel
One Civic Square
Carmel, IN 46032
RE: Carmel Centre West Project
Southeast corner of 1061h Street and Commerce Drive
Our File Number: 2082/1
Dear Scott:
On March 21,2002, we will file with the City of Carmel Department of Community Services,
on behalf of West 106\h Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast corner
of 1061h Street and Commerce Drive 10 Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17,2002 agenda of the Technical
AdvisOlY Conunittee and the agenda of the Cannel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If YOll have any questions regarding this matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Very truly yours,
TH E RE [S LA W FIRM, LLC
~~
Attorney for West 1061h Properties, LLC
Enclosure
cc Jon Dobosiewicz, City of Cannel
I ,i '.I ~: fj H /', Ii I: U C h. S T Ii I: 1,1
c ,~_ R ~:'/:,E, L I I I~~ I.:. 6 C- J .':~
) I .,. - li ~ {:, <, L ::; ~j ')
\=." J~\)~ ~~ 1 '7 .. 8 i; ~~' _ ;~_;~ ,} I)
i-, r? \'1 f~~l ~-;' [ I ~~ '~ to. ~'f L.) t,_,<
."
u
u
THE REIS LAW F1RMt LLC
Writer's Direct Dial
(317) 848-4886
preis@reislaw.com
March 20, 2002
Mr. Jeff Kendall
Building Commissioner
City ofeanne!
One Civic Square
Carmel, IN 46032
RE: Carmel Centre West Project
Southeast comer of 106lh Street and Commerce Drive
Our File Number: 2082/1
Dear Jeff:
On March 21, 2002, we will file with the City of Carmel Department of Community Services,
on behalf of West 106lh Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of 1061h Street and Commerce Dnve in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
if you have any questions regarding this matter in the mean time, please feel free to contact
mc at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assis tance,
Very tmly yours,
THE REIS LAW FIRM, LLC
Enclosure
cc: Jon Dobosiewicz, City of Carmel
-! ~' J :", 8 h ft f\l C C C \-:, ~.:. T E ;~ t T
c p ,~ I,rl E i". ii"
! , " .~ ~.
~..; ~:.: u ~:. ,~_
:: 'I 7 c 8 ~ tt .' ~ B ~i ~~I
.j 'J 'I - ~:~ /j {:J
!: 2: ~. i,J
~~ f ~ I'j!e Ii [I :.~ L I~-. :~,' ,_~ i_' I '~, .
,
~'CLL
,~_:._t~_-_,_.: _
. . '>', r-" ~ :'-l:' ,;
u
u
THE RE I 5 LAW FIR M, L L C
Writer's Direcl Dial
(317) 848-4886
preis@reisJaw.colll
March 20, 2002
Ms. Sharon Prater
Panhandle Eastern Pipeline Co.
P.O. Box 38
Zionsvllle, IN 46077
RE: Carmel Centre West Project
Southeast comer of l06th Street and Commerce Drive
Our FileNumber: 2082/1
Dear Ms. Prater:
On March 21,2002, we will file with the City of Carmel Department of Community Services,
on behalf of West l06lh Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of 106111 Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Conunittee and the agtmda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regarding thIS matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance
Very tnlly yours,
THE REJS LAW FIRM, LLC
,-- 3th fJ~.~
uz;-u -
Attorney for West 106lh Properties, LLC
Enclosure
cc: Jon Doboslewicz, Clty of Carmel
1 2.:j:J 8 H!I I'. C (I ::' f. S r f;: to. l, T
C t\ >'; H I:' t., ii" I, 0 0 ~: :)
:;'1 1--8l~8-1"S81j
~.:;"~ r :.} 'j '/ .~ f~~ ,.~;:-, ~ El ';' ~_1
,- : .:. l,'t ~~~ F~ E ! :::. L . \"'" ,'3,
..
u
w
THE REIS LAW FIRM, LlC
Writer's Direct Dial
(3] 7) 848-4886
preis@reislaw.com
March 20, 2002
My. Jay W. Alley
Clay Township Regional Waste District
10701 N. College Ave., Suite A
illdianapolis,L'J 46280-1098
RE: Carmel Centre West Project
Southeast comerof 10611. Street and Commerce Drive
Our File Number: 2082/t
Dear Jay:
On March 21, 2002, we will file with the City of Carmel Department of Communi ty Services,
on behalf of West 106lh Properties, LLC, ADLS .and Development Plan Applications and
corresponding plans for the professional and general office buildings located at the southeast comer
of 1 06th Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17,2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review of the enclosed plans to me or Mark Monroe at our
office address lIsted above.
If you have any questions regarding thlS matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Very truly yours,
THE REfS LA W FIRM, LLC
~/ tt:
' '
Rau'. Rei'
Attorney foc est 106'" Properties, He
Enclosure
cc: .Jon Dobosiewicz, City of Cannel
"\ ? :~~ ~iH ! i )1-, ~,:- ~.: D C I~: S l H E E "r
C:: i-\ I~ 1'.11 E L. 1 i", f: t:J U ,j 2
::: -" r~ _ S 1~;9 I:; ~1 ~~ ~,
i':: iJ, x; 'I ',I _. ;~tl i.~) .~ ~~ t)' i
F i f' H 1(\ ,~'- E: I i l",,';'," I' "i
..
u
u
THE RE~S lAW FIRM, lLC
Writer's Direct Dial
(317) 848-4886
preis@rcislaw.com
March 20, 2002
Mr. Ron Lauritsen
Samuel L. Moore & Assoc.
7102 Lakeview Parkway West Drive
Indianapolis, IN 46268
RE: Carmel Centre West Project
Southeast comer of 106th Street and Commerce Drive
Our File Number: 2082/1
Dear Mr. Lauritsen:
On March 21, 2002, we will file with the City of Cannel Department of Community ServIces,
on behalf of West I06lh Properties, LLC, ADLS and Development Plan Applications and
corresponding plans for the professional and general ot1ice buildings located at the southeast comer
of 1061h Street and Commerce Drive in Clay Township, Hamilton County, Indiana. Enclosed herewith
are the site construction drawings for your review.
We are anticipating having this project placed on the April 17, 2002 agenda of the Technical
Advisory Committee and the agenda of the Carmel/Clay Plan Commission for May 21, 2002. Please
forward any comments you have after your review' of the enclosed plans to me or Mark Monroe at our
office address listed above.
If you have any questions regarding this matter in the mean time, please feel free to contact
me at 848-4886, or Mark Monroe at 848-4887. Thank you very much for your cooperation and
assistance.
Very truly yours,
THE REIS LA W FIR.:c1\1, LLC
h1~V. ..Awr~
Mark T Monroe, Land Usc Planner
Enclosurc
cc: Mr. Jon Dobosiewicz
Mr. Jay Ailey (w/o plans)
"\ i:- ~~! .s n H .J.1. r,~ C i.J C, 1.(\ S', R E E T
l~ A r, Ivi E L. I 1\1 ,;, 6 !J '-I ;':
;j '1 ~l - a II l~ . l~ R -:'3 ~.;
i~' !~..}~ ~3 ~ ')' - 8 h, ~l . '-~', !~ ~j .~/
t= i fl.' \,.:. rl;1 h E' ~ ~., ~. V:.,i C' :-_~ \'."i
';J
I
Mi
u
u
u
Transmittal
Mid-States Engineering
350 East New York Street
Indianapolis. IN 461;04
Phone: 317634-6434
To:
City of Carmell Dept. of Community Services
Date: 11/1/2001
Address:
One Civic Square
City, ST,
Zip:
Car8mll Indiana 46032
Attention:
Mr. Laurence Lillig
Project: l06th & Commerce Dr.
Re:
Preliminary Site plan
Job No.: N/ A
Mail b8J
Messenger 0
Express 0
Pick-Up D
We are sending herewith:
Check
Descri tion
Co ies
IZl Preliminary Site plan
D
D
o
D
D
o
[8J
D
D
lZJ
/--:\\-~ -.-
/: t .\
/"". .
6""~~~
-! "0' L-;';:;
r,1 r":J CO\, ~
..\lJ {i:j SJ
-:\ ~ t&
f~\.
>~ ~\
"~-..o:> /('i1"
-. 'it> ,;". \"-J'?
li-t.'"
The information as per your request
Please review and respond
See remarks below
Remarks: In anticipation of our meeting on Monday morningl I am forwarding .the attached preliminary site plan
Gu your cursory review. please contact our office if you have any questions. Thank YOUl for your assistance.
from: Victor Reyes
D Correspondence
CC: Mike DeBoy, LS; frank Swiss