HomeMy WebLinkAbout07100119 Site PlanThe 9eEaeider corporation
On OW Awesae
Historic Port Hammy
todieeepoW, gene 14216-1037
317-826-7100
317-426-7200 PAX
This Plot Ran Prepared For M/I Homes
Lot # 28, containing 10,261 S.F.t, in
Heather Knell
Section 1
Instrument X003045
P.C. 3, Slide 560
Clay Toomsitip, Hamilton County
SEC 20, 118K R03E
14276 CAMDEN LANE ( 50' R/1111)
Westfield, IN 46074
Prepared Date: 10/01/07: By KAG
Community Restrictions:
Side Yard = 7 min.
Aggregate = 6' B.H.
Zoning - S1
MA HOMES
Pad Grade = 917.9 per talc.
Pad Grade + 0.2' = Garage FFE (918.1 )
Garage FFE + 0.5 = Residential FFE (918.6 )
Residential FFE - 9.0' = Basement fFE (909.6 )
Driveway Slope = 4.2%
NOTE: GARAGE F.F.E. IS PROPOSED TO BE
1.5' ABOVE CURB AT DRIVEWAY T.B.M.
GROUND COVER CALCULATIONS:
Drive = 863 SFf
Public Walk =319 SF::
Private Walk =N/A SFt
Seeding =5,246 SFd:
Sod =263 SY3,
from front of residence.
m1?
FLOOD HAZARD STATEMENT
CERTIFICATION
\\\\\\\\\0 \\\\\ 1111 I I I I I I I I I I/ 11, %//
L
4.av5TERfp''•:?i4
o`?P No. - -? -_
S0303
z / STATE OF c
7i/77 / I ! / 11 / 11 I I I I I I I 1111 111 \ \ \ \ \\
REVISION #1
DELETED FULL BSMT.,
FULL PORCH, 4'
COMBINED BUTAP AND
BREAKFAST BAY
ADDED PARTIAL BSMT.
V B07.00815311
10112107 - KAG
This drawing is not int dad to a represented as a retrocement or
original boundary survey, o route survey, or a Surveyor Location Report
Flood Hazard Statement: The accuracy of any flood hazard data shown on
this plot plan is subject to map scale uncertainty and to any other
uncertainly in location or elevation on the referenced flood insurance rate
mop (FORM). ALL of the within described land DOES NOT UE within that
special flood hazard zone 'e, as said land plots by scale on Community
Map Panel / 1BDO810001C of the flood insurance rate maps (FIRM) for
Hamilton County, Indiana, Dated May 19, 1981.
kobeutq Note:
swseykfl This drawing is based on construction plans or record drawings,
Leadarnpe Architecture and is not based upon a field survey. The Schneider Corporation
ore • US does not warrant the accuracy or sufficiency of this information.
Genlop - Contractors should verity existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately, foiling to do
so results in the contractors assumption of oil liability.
Plot Pion Legend
CM Proposed Grades
000.0 Existing Grades
X000.0- Contour Grade
* Approx. Lateral Location
e - Sanitary Sewer Lines
?6r - Storm Sewer Lines
- v - Water Service Lines
- - - - - - Sub-Surface Drain Limes
fa Manhole (Sanitary or Storm)
® Beehive Inlet (Storm)
® Curb Inlet (Storm)
D End Section (Storm)
14 Fire Hydrant
now Line of swale
- Building Line (BL / BSL)
- - - - - - - Easement Line
Notr
the moeaent elevation, depicted hereaL has been determined end
based on the pod grades and/or contoura taken from the
construction pions for the subdivision. unless staled, no hiormolion
about fluctuating water tables, sal conditions, or soil'tyaes has
been provided or staled on mid plan This lot is located nee o
body of water. Lot or sail conditions may require that the basement
floor devotion be held 2 kol adore normal pod elevation. Site
investigation may be needed R voter is enceunlered during the
eamotion process or if other knew, water elevation or sole
conditions we present. Investigation and my remedial procedures is
at the discretion of the builder to determine and lake Wpmpnote
slaps of action. If any ground water is encountered "
excoratim the buide is encowaged to contact The Schneider
copootion to d'earss possale causes of action.
IP PUMP(S) TO BE PLACED
BUILDER AS NEEDED. LOT ??p?7.008 # ? 28
8
YDV08 /
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC=916.39
Downstream Manhole, TC=917.54
per record dreg.
Note The contractor is to maintain a
minimum distance of ten fat (10')
between the sanitary sewer and water
line laterals.
Note: Builder to ensure positive
drainage away from structure(s).
0
-AMo
MHPIO U
Trf916.38 Assumed North
PER RECOim Scale : 1' = 30'
DRAWNG
a
I I II ? I? ?
- I 1
11.1' ----- _- I I
? W
30.0'
50.4 35.67 nv °-
I ` - B-B
I
1 I u' ?d?= m
? ?
^ 3 I
W I
I
? cr)
I
iDAo'- m
48
5 N
.
T
a 35 >-tY - Q I
00
2 ~
Z 01 PER PUN
10.00'
16W i W i.
?? ?y
6
??y
?
l n I
I C
?? ¢
I
?
I,
z
o
3? I U
8
m l 1 o _ 20' I I
I I )( I
' ?
I n I I
I
It.2
,
1
-, 91 7.1 1 0
1
1 PER
ftAN '
916.5 CA R 917.6 127.22 1
VAR. D.U.AS.SE.A
L ILLEARP.AE. O°u ?' I 1
z
4:7 SLOPE 4:? 51,OPE
TYPICAL SWALE SECTION
NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING
HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING
MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35)
FEET PROVIDED THE SIDE AND REAR YARDS ARE
INCREASED AN ADDITIONAL FOOT FOR EACH FOOT
SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET
IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.