Loading...
HomeMy WebLinkAbout971358B Sewer/Water Permit/sa CLAY TOWNSHIP REGIONAL WASTE DISTRICT FINAL SANITARY SEWER PERMIT INDIVIDUAL LOTSIEXISTING BUILDINGS Project Title: MY WASTE VEM City: Calrid Zip: yAb ,J - Availability Paid: Connection Fee Paid: Interceptor Charges Paid: Surcharges: •?B,*V PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste District (see reverse), All installations shall be inspected by District, personnel during "open trench" phase and'before backfilling with sand or stone to six- inches above the. pipe: NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewersystem. The District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible. For damages to the-District's sewers system including manholes, castings, manhole lids and the like, caused by construction activity on the building site which is the subject of this permit,.the permit holder is also responsible. Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200 one to four hours in advance. All new construction will be placed on trilling six months after connection has been made. By signing below,.l attest that I am familiar with the District's specifications and agree to accept responsibility for all work done under this permit. / Build r/Ownef Signalure Phone 0?- OyCO sdp e tans submitted y? Inspection Fee Pain: 5S 500 C? -2 G Permit issued this /3 day of, '199 // 7 •. CT W i r Jay W. Alley, Utility Manager ys cs?``O ArPRIGIOtANV Permit valid only with red ink. rev. 11L1-BElcjl L'ot# In Street Address-,-5 ? R ,71,'1 ?T. CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUMMARY OF LAT RA INSTALLATION gEQ IIgEMENTC C"r 1. All houses, buildings, etc., shall connect to the District's. sanitary sewer'system within.90 •e days of notice providing a sewer is within 300 feet of the property line. 2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to the District's sanitary sewer. 3. The existing sewer line from the building to the, septic tank may only be used_if it is located under a building addition, patio, porch or paved driveway and can be air tested to show it is acceptable for re-use. The property owner shall bear the cost of all testing and,pay the District. for inspection of the air test. 4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made one to four hours.prior to'the need for the inspection. If the inspection fails and a second inspection is required, an additional fee of $55.00 will be charged at the time of the follow up'inspection. 5. Property owners are hereby advised that Hamilton County regulates the operation and maintenance of private sewage disposal (septic) systems. County Ordinance No. 8-1-83 provides in part that, upon connection to a public sewer, a septic tank "...shall be abandoned and filled with earthen material' in a safe and sanitary manner." Compliance with this ordinance is strongly encouraged. Please contact the Hamilton. County Board of Health for further information. 6: Acceptable Pipe Materials: PVC PIPE: SDR 35, ASTM D-3034, SIX INCH PIPE GASKETED,JOINTS: ASTM D'3212 GASKETS: ASTM F-477 FITTINGS: SDR-26 7. Bedding: Use fill sand or Number 8, 9 or 11 stone Fill material is to be placed from 6 inches below to 6 inchesabove the pipe, The trench should be a minimum of 18 inches wide. 8. Laterals shall be installed no closer than 20 feet from water wells unless water grade PVC pressure pipe is used meeting SDR 26 and ASTM D-2241 9. Laterals shall terminate within 3 feet of the building unless the conditions in Item #3 above are met. 10. Additional information on District standards and specifications may be obtained from the District's office during business hours of 8:00-a. m. to 12:00 Noon and 1:00 p: m. until 5:00 p. m: Monday through Friday: Clay Township Regional Waste District 10801 N. College Avenue Phone: 844-9200 Fax: 844-9203 11. Septic effluent shall not be pumped out into the-new sanitary sewer system. Rev. 11.1,96 LOT 10, SFRDVG LAKE =A= &TE PLAN = FMISH OWE = SURFACE FLOW NORTH GRAPHIC SCALE mmmmu. 0 15 30 60 SCALE : 1" = 30' J08 No. 824527 N 8 1 ' 3° 84 44' 0h < FM I LOT 10 i g Ln -?y / i ti o ??? o 2 m I 0 / Y / / I\ i F I-- -- ?. is- V Lih\ I LLL ??.?llyll U& h fog V 1--` ?"°°vlfll I 0. o ? ?Ok?OA ? N { a ?nf Q??ic?o I i '- ?J 48.5 I { i CONC. ORNE Iu n; ? v h? 3o,?- 3N DATE: PINTAIL COURT R.L. NOV. 7, 1997 S0083 A2IIMSURVEYING 948CONIMSTNOBIMSVI.B,IN.Pb.-773-264,4 FOR: SHM:1ELD HOMES- ?f !a I -Ab 0 ` f O