HomeMy WebLinkAbout07110076 Sewer/Water Permit/sCITY OF CARMEL
Item 1 of 1
DATE ISSUED.......: 11/16/2007
RECEIPT #.........: 26804
REFERENCE ID # ...: 07110075
OPERATOR: pl
COPY # : 1
Sec:8 Twp:17 Rng:3 Sub:WG2 Elk: Lot:28
PARCEL ID ........: ZWG228
SITE ADDRESS .....
SUBDIVISION ......
CITY .............:
IMPACT AREA ......
PERMIT RECEIPT
105661 IRON HORSE LN
WINDSOR GROVE II
CARMEL
OWNER DAVID MORTON
ADDRESS ..........: 1018 HENLEY CIRCLE
CITY/STATE/ZIP ...: CARMEL, IN 46032
RECEIVED FROM ....: DAVID MORTON DESIGN
CONTRACTOR .......: LIC # XHICKEXC
COMPANY ..........: HICKORY EXCAVATING
ADDRESS ..........: 308 S. CLARK
CITY/STATE/ZIP ...: COLFAX, IN 46035
TELEPHONE ........:
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT
---------- ------------- ---------- -- -- ----------
USFWATCONN FLAT RATE 1.00 1310.00 0.00
UWATERTAP FLAT RATE 1.00 86.00 0.00
---------- ----------
TOTAL PERMIT 13966.00 0.00
METHOD OF PAYMENT AMOUNT NUMBER
----------------- ------------ ------------------
CHECK 1396.00 4695
TOTAL RECEIPT 1396.00
THIS REC NEW PAL
---------- ----------
1310.00 0.00
86.00 0.00
---------- ----------
1396.00 0.00
CITY OF CARMEL / CLAY TOWNSHIP
WATER / SEWER PERMIT / RECEIPT
!hmzM-'
PARCEL ID #: ZWG228
LOT & SUBDIVISION: 28 WINDSOR GROVE II
ADDRESS OF CONSTRUCTION: 10561 IRON HORSE LN CARMEL, IN 46032
PAYMENT RECEIVED FROM:
Name: DAVID MORTON DESIGN
CHECK #: 4695
EXCAVATOR INFORMATION:
Name: HICKORY EXCAVATING
Ph. #: Fax #: Email:
Street Address: 308 S. CLARK COLFAX, IN 46035
Bond Expiration:
PERMIT TYPE: USEWRWATR , SEWER/WATER PERMIT
Notes/Conditions:
28 WINDSOR GROVE II. WATER PERMIT
'NO NOTES`
Permit#: 07110075
Date: 11/16/2007
The building & Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting
ASTNI specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. 'Ilene sewer
shall be installed in accordance with ASTM 2321 for pve pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a). and sections 113008-1 and 2 of the International Residential Code. All building sewers shall be 6" diameter.
All installations shall h- °open trench" inspected and appro% red by the Camel Sewer Department before anv backfillmr, is done. Non-
compliance may result in digging up the sewer installation andtor denial of future sewer permits and/or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sewer inspection should be requested at (317) 571-2645 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements arc made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the C1 FY ENGINEER'S OFFICE. If any street
MINT he cut" a Nenarnte street out nermit shall he nblained.
APPLICANT NAME: DAVID MORTON
PAYMENT RECEIVED BY:
FEES:
$1,396.00
Regional Waste ®istric
Residential SANITARY SEWER PERMIT
00704 INDIVIDUAL LOT I EXISTING BUILDINGS
Permit Type Final
Subdivision Windsor Grove-11-
Section Number 2
Lift Station
---------- 09 Towne Road Station
--------------------------
Treatment Plant CTRWD WWTP
__
-
Builder Dave yMorton
Phone Number 317-844-l304
Parcel Acreage
EDU in Gallons 310
---------------- - --------------
Invoice Number
Lot Number 28
Address Number 10561
------------------ - --------
Street iron Horse Ln
------------------------------------
city Carmel
---------------------------------------
Zip Code 46032
--------------------- - -------------
County Hamilton
----------- - -----
Local Sewer Charge
- - Plain Review and Inspection
Application Fee _ __ _ _ _ _ __ _ _ _ $100.00
EDU Fee $1,650.00
-------------------------- -
Interceptor Fee
------------------------------
Fees 'Due $1;750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected.by District personnel during
"open trench" phase_and before backfilling with stone to twelve inches above the,pipe. NO footing or foundation
drains, or other sources of ground orstormwater, shall be permitted to enter the District's sanitarysewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nori , for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder
will be responsible for damages to.the District's sewer system. This includes damages to'manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844=9200
24 hours in advance. All new construction will be placed on trilling six months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH WG-ios WG-104 DSMH
Grease Trap
------ No
----- Slab Foundation
-- No
-.---- Lid Elevation 892,00 ft
------------- 886.46 ft
-----------
Grit Interceptor No Crawl Space No First Floor Elevation 896.00 fl 996.0011
Grinder Station No Basement- Yes Basement Elevation 886.00 It 886.0011
Calculation is based. on. both Manhole Lid Elevations and the elevation of the First Floor E4.00
9.54
Per Ordinance 9-13=99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.I
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
AII: conditions have been met Connection to the sanitary sewer is now permitted.
CTq?
v
By signing below, I attest. that I am
Builder / Owner Signature
Printed Name
Approved
the Di tic' ci cations and agree to accept responsibility for all work done under this permit.
Phone Numbers 1 7 ?7 -l 3 0
Permit Date 11/1612007
Revised 7126107 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SUMMARY'OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of.notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the, District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used, if it is located under a building
addition,,patio; porch orpa4ed driveway. Air test'is`t6quired'to show if acceptable for're-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or-contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine c_ ompliance'with the District's sewer use ordinance. Such notification shall'be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal. (septic) systems. The County Ordinance provides in part that, upon connection4o a public
sewer, a septic tank".:.shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26;.ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS:,ASTM F477
FITTINGS: SDR_26 or better (NO femco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number '8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of18'inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used.meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3,feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web.site
at-http://www.ctiwd.org/. _
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12: Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verity placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10109107
L" Group
xncf Surveyors
Vest Carmel Drive, Carmel, IN 46032
7.844.3333 F 317.844.3383
www.seagrouplic.com
00.0 PROPOSED GRADE PER PLAN
OG.O EXISTING GRADE REC. DWG.
- GROUND WATER FLOW
s.H SANITARY SEWER LINE
mm- STORM SEWER LINE
rrm -TM- WATER UNE
------------- EASENEIIT LINE
BUILDING SETBACK LINE
LOCATION OF UTILITY
LATERALS ON PLOT PLAN
ARE GENERAL LOCATIONS
PER PLAN AND SHOULD BE
VERFIED IN THE FIELD.
NOTE.
BUILDER TO ENSURE POSITIVE
FLOW AWAY FROM
STRUCTURE.
NOTE:
SUMP TO BE PLACED 3Y
BUILDER AS NEEOEG.
i
LOT# 28
21,800 S.]
PLOT PLAN WAS '1\
'AP,ED BASED ON 888.1
EXISTING POND
RMATION TAKEN FROM o t NP-884.83
)RD PLATS, SUBDIVISION \ ?, 0 NO 100 YEAR ELEV.
IS, RECORD DRAWINGS STATED ON PLANS
PLANS PROVIDED BY FOR LOT OT OD 28 -887.00 PROTECTION PER ER PLAN GRADE
NT, IT IS THE
C. A. &L.
'ON5181LITY OF THE \ ., ?ES VAR. D.D. E.fdM.A.E.
'RACTOR TO VERIFY SITE
)ITIONS PRIOR TO cJ? \
3TRUCTION AND NOTLFY ?\c? ??? /
S E A GROUP LLC OF `'"?%s 4\
DISCREPANCIES.
?? gyp ?_ e'se-D
11MUM SETBACKS °F
SID- YARD = 10 Fe=t
REAR YARD = 20 Feet
Z0 Feet \ ??z?>33•
14-, / CN:ILEvER PAY WN)OV+
g0 ` /
LEE
E2.7'
??i°J' v A NL'i V'ER AY lNNDO'W
?} QD i DECK ? ?
s°' PROPOSED 6 J2 ??
FRM k MSY EG /
RESDENCE
\ FFE-E9E.0 "
EE
892.0 ESMT p? 88].0
tl / ?0
GARAGE 891.5
\?/ FPE=892,0 CONC
1 1890.90 \ \\ `FLe ?`y'?\ 2E OPI`.E
E O
\\\\ ?\ \\+r' \ryq\ ti 6? 891.5 2s-0' / ?.
\ \ !-NN
\
\\ .'fO \\ /J 30.0•
(15) ti ? \
DDOW,. `SO,(\?-`S[? \\+,i s1.c 1 /
?'j eeE.9
AN
Sao E.tT.
\\ \ ` \ `\ SS \ 888.E
`
\ \
'N 61?
9E7.7{1\ \
\\\` \\\
SAN. STP._ ;10,
TC-EEE.4E
PER REC. DWG,
dy Dexro ion:
umber 28 in Windsor Grove, Section II an Addition in Hamilton County, Indiana, as
Iat thereof recorded as Instrument Number 200600068094 found in the Office of
scorder of Hamilton County, Indiana.
PLOT PLAN
le: 1"= 30'
e: 00. 9, 2007
Drawn by: GJR
Revised:
Prepared For:
David Morton
Designer Builder, Inc
Residence
10561 Iron Horse Lane
GRAI......
No.
* LS20200083
STATE OF
'????? nnn iii ?```
ILI?1? -