Loading...
HomeMy WebLinkAbout07110107 Pool Plansf .. CS, ;,', 3 S/+^W?/jar •" 4? 3 L??TSR L,,. ri _ ?? fo?w ?,5 wr ?? L/ ?C8AI of /L D. S/DF VIEW. 1"0oL Sly/-'Ll- _/,,o SKr hOOL _?9 La T- ?- Po o GENERAL NOTES I. Install a cm as requlred by the INaJocal Electric Code and the Canadian Electrical Code. 2. All wiring should be done by a licensed electrical con- iracior in accordance With local electrical codes and as i .required by the National Electrlc Code or the Canadian ' Electrical Code, as applicable. 3. See Table I for recommended pool lighting levels. See Ta=le II, Page 5, (of light niche 'pull: anc cord szecifi:a- lias. G CAUTION Risk of burns. Lights over 100Vd, not rec. cmmended for spa Installation. Table I: Typical Lighting Requirements Allowance of W'atu/Sq. Fool -Type of Pool rot Pocl Area - small Residential Pools (Less than a00 sq. R, (75 sq, m,I) 112 to 1 Large Public Pools I to 1'1/2 Dying Pools (Less.man 12 h. (3.55M) deer) 1.1/2 to 2 Diving Pools (a 2 to 20 h. (3.53 to 6M) deep) 2 t0-5 Compethion Pools 2 to 3' pne 500 W'aa llght al detp.end of pool is recommended. " Fcr compentlon pools: , ? . i. Make SWe Thai the siaNfirilsh ends of lines are well ilg;red, :. never install liahis in end wails at ens of swimming liner. Howe,er ii shen course ruing is provided across fne width of a 5. meter ca.ae, lighs fixtures may be Icstalled ;etaveen lanes lancer racing lines) on a separate switch.' - - ' JUNCTION BOX Locate Min. 4'0• (1220 mn) Behind Pocl Wall and Alin a• (203 mm) Above Up of Coping From er.s'upply conduit from h'loh. Figure 7 junction Box, Part #05730.0021 : B' Nln. (201 mm) " - Lip of Coping Elwadan . .:? .?tt!!'(Satmm)-.t`-•:.YI•(,RnS m.'n) 5.? mmf to Mimi i.- (a7a con n. Lens _ I ?.ly? Nkha Con,. I IF-1 c . " 'e• Bulb-? ?tJ}{ r 1,a2' V.W vl He Rtl •U :alli: waterproclL?y ` ? I ComPwna /toe RIn9 LIynl Cora ccacvP. i r (zee mm) Figure 2: Niche Dimensions JuncV?) GPinq eo2?? Deck Tlie I Ur. ' ? • Le . ? c Level . .. G c . • .. , o .o o , 0 .0 It o r• ' I . W. eC' p ' • To :unc9on MM - ? 1121 mm) o r • ' e. J/'l13.J5 my :5A ` 1'' 0 ? mo or ( . 01 Acprv. a-. f • S.S. LIi 1: rUG`.• N0, 60ba--0D12Y<-113: )5 mr No, 6D66 -,M) ' o •v . : - ? Undervaler'_'gN e a Approves' r a,• Qroun', Clamp I. _ r wn. O,' .. - (107 mm) 1-4 hue (E.W.) Figure 3: Niche Installation in Gunite Pool any.persen from contacting it, install the fixture in of or pool wall with the top of the lens opening at least 16 r. (.5M)•below the normal water. level of the pool. • Llghts'and niches shell be used.in fresh water pools on • The lens is het[ resistant glass and focuses the light be, in a 301 horizontal arc, with 15•. downward deltelcuon and is sealed by a molded one-piece wrap-aro',.nc nEo prene gasket, A stainless steel face ring with 10 micunt!