HomeMy WebLinkAbout07100179 Sewer/Water Permit/sCITY OF CARMEIL
Item 1 of 1 PERMIT RECEIPT OPERATOR: twedding
COPY # , : =
Sec:20 Twp:19 Rng:03 Sub:HEK Blk:l LOt:23
PARCEL ID ........: ZHEK23
DATE ISSUED.......: 10/26/2007
RECEIPT 4.........: 26648
REFERENCE ID # ...: 07100178
SITE ADDRESS .
SUBDIVISION .
CITY .........
IMPACT AREA ..
OWNER ........
ADDRESS ......
CITY/STATE/ZIP
RECEIVED FROM
CONTRACTOR ...
COMPKAY ......
ADDRESS .
CITY/STATE/ZIP
TELEPHONE ....
14317 SAINT CLAIR LN
HEATHER KNOLL
WESTFIELD
M/I HOMES
8500 KEYSTONE CROSSING
INDIANAPOLIS, IN 46240
M/I HOMES OF INDIANA
LIC # XRTMOOR
R.T. MOORE CO., INC.
6340 LAPAS TRL
INDIANAPOLIS, IN 46259
(317) 291-1052
FEE ID UNIT QUANTITY AMOUNT PD-
-
- TO-DT
------ THIS REC
-- -------- NEW BAL
--
-------
---------- -----------
USFWATCONN FLAT RATE -- ----------
1.00 -
---------- -
3io .00 0.00 1310.00 -
0:00
UWATERTAP FLAT RATE 1.00 86.00 0.00
-- 96.00
-------- 0.00
- ---
TOTAL PERMIT ---------- ---
1396.00 -
0.00 1396.00 0.00
METHOD OF PAYMENT AMOUNT NUMBER
--------------
----
----------------- -
CHECK ----
1396.00 14875
TOTAL RECEIPT 1396.00
SCANNED
CITY OF CARMEL / CLAY TOWNSHIP Permit #: 07100178
i WATER / SEWER PERMIT / RECEIPT Date: 10/26/2007
? ?IPNP- PARCEL ID #: ZHEK23
LOT & SUBDIVISION: 23 HEATHER KNOLL
ADDRESS OF CONSTRUCTION: 14317 SAINT CLAIR LN W ESTFIELD, IN 46074
PAYMENT RECEIVED FROM:
Name: M/I HOMES OF INDIANA
CHECK #: 14875
EXCAVATOR INFORMATION:
Name: R.T. MOORE CO., INC.
Ph. #: (317) 291-1052 Fax #: Email:
Street Address: 6340 LAPAS TRL INDIANAPOLIS, IN 46268
Bond Expiration:
PERMIT TYPE: USEWRWATR
SEWER/WATER PERMIT
The building & Sewer Shall be pvc sewer pipe meeting ASTM specifications :034 SDR 35 of latest revision: or vitrified clay pipe, meeting
.ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTM 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6" diameter.
All installations shall be "open trench" inspected and approved by the Carmel Sewer Department before any backf fling is done. Non-
compliance may result in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sewer inspections should be requested at (317) 571-M,IS one to four hour in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumber or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY" ENGINEER'S OFFICE,. If any street
must he cut_ a wnarate street cut nermn shall he nhiained-
APPLICANT NAME: R L GROCE
r
PAYMENT RECEIVED BY.
FEES:
$1,396.00
SCANNED
4 c°
Regional Waste District
ill 116 Residential SANITARY SEWER PERMIT
00674 INDIVIDUAL LOT/ EXISTING BUILDINGS
Permit Type Final
Subdivision
---------- Heather Knoll
--------------------------
Section Number
------- 1
----------------
Lift Station - 23-1-26th-Street Station
Treatment Plant MIX
Builder M/1 Homes
---------------
P hone Number Parcel Acreage
------------- ------
EDU in Gallons 310
Invoice Number
Lot Number 23
Address Number 14317
Street. Saint ClairLn
city Westfield
Zip Code
--'----`----------- 46074
--------------
County Hamilton
Local Sewer. Charge
Plan Review and Inspection
Application Fee $100.00
EDU Fee $1,650.00
Interceptor Fee
Fees' Due
PLEASE NOTE: Installation or building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse),and any conditions noted below. All installations shall be inspected by District personnel during
.'open trench" phase and before backfilling with stone to twelve inches'above the pipe. NO'footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of"the nearest downstream manhole nor for
laterals which are extended beneath driveways or.sidewalks. The permit holder (property owner, developer or builder)
will be responsible' for damages to lhe,District's sewer system. This includes damages to.manholes,-castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 644-9200
24 hours in advance. All new construction will be placed on.billing six months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH HK-715 HK-713 DSMH
Grease Trap No
- Slab Foundation No Lid Elevation 920.01 ft 918.53 ft
.
Grit Interceptor
- No Crawl Space
- - - - No First Floor Elevation 921.10 It 921.10 It
Grinder Station No Basement Yes Basement Elevation 912.10 it 912.10 ft
- - ---------- ---------- --
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 1.09.
and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible at all limes. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met Connection to the sanitary sewer is now
CTRWD
By signing below, fattest that I am fal ltliar wfth the District's
Builder/ Owner Signature
Printed Name
agree to accept responsibility for all work done under this permit..
Phone Number
Permit Date 1012612007
Revised 7126107 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SCANNED
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the'District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 1,00 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral.installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio; porch or paved driveway. Air testis required to show if ac`ceptable'forre-use. The' property-owner
shall bear the.cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The.owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not'on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior: to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance.provides in part that,.upon connection to a public
sewer, aseptic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitarymanner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR'21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21;
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS:ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IROWMECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR11 with Compression Fittings, Mechanical orElectrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR'21 and ASTM D2241. Any proposed installation requiring, pressure pipe shall be reviewed and accepted.by the
District and the Districts engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:60a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at http:l/www.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours, prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15: Call before you dig. IUP.PS 1-800-382-5544, 48 hours prior to.digging.
Revised 10109107
The 9chaeider Corporation bowe4q Note:
I= Otte Arenas 9orweym This drawing is based on construction plans or record drawings,
Historic Pat Rarrison Landscape Architecture and is not based upon a field survey. The Schneider Corporation
IadlwaeooYx Inman 46MO-1037 GIs • us does not warrant the accuracy or sufficiency of this information.
917-828-7100 Geolnp Contractors should verify existing conditions prior to any
w 917-1128-7.00 FAX construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately, failing to do
sin results in the contractors assumption of all lability.
This Plot Plan Prepared For III Hanes Note:
Lot # 23, containing10,886 S.F.t, in Plot Plan Legend The been. ent devotion, depicted hereon' bas balm determined and
HBOtfI? ?? based an the pad grades and/w contours taken from the
® Proposed Grades construction plans for this srbdivisim Udas doled no
Section # 1 000.0 Exiling Grades 'information dour fluctuating water tmla eel cokilicas, or sed
Instrument -oDoo- Contour Grade tees has been provided or stated on sod pWn This lot is
?5 ?k Approx. Lateral Location totaled near a body of water. Lot or son conditions may require
P.C. 3e side 560 Sanitary Sewer Lines that the basemnt now devo5n be held 2 foot above normal
i
pool goy Toons}lip, Hamilton County Wit Storm Sewer Lines Mdemon. duduring the the e o t cmJion may prbeons or if o needed if water
other er k is
.lam T18 8K1N, My v Water Service Lines ekwli n fle, Or cede conditions we prpot L Irivestigolion m water
and
SEC 20, _ _ _ _ _ _ Sub-Surface Drain Lines renwdid al procedures is at s at the we n of the budder and my
dajW-s O
14317 SAINT GLAIR-LANE ? 50'- -R? -® -Manhole -(Sanitoryor Storm) ?term:ro md`iake ggrapriale sliyi of-the oNun: 1fWrgr
gourd -
Westfield, IN 46074 0 Beehive Inlet (Storm) water is encountered during excavation the holder is encouraged
j The scniwlder corporation to Scones Possible =rSee
Prepared Dote: 10 16 07 : B KAG ® Curb Inlet (Storm) o ?m
Y % Foe N End ydlanrant (Storm) LOT # 23
Community Restrictions: -ova - a
side Yard = 3' min. - - Building Flow Line Line Line e (BL (Bole / BSL) NOTE: M7.10=0
Aggregate = 6' B.H. - - - - - - - Eosement Line SUMP PUMP(S) TO BE PLACED -
Zoning - S1 BY BUILDER AS NEEDED. Q
M/1 HOLIES Note: Sanitary Sewer Note: Builder to ensure positive
Pad Grade = 920.4 per plan Top of Casting Information drainage away from structure(s).
Pod Grade + 0.2' = Garage FFE (920.6) Upstream Manhole, TC=920.01
Geroge FFE + 0.5' = Residential FFE (921.1 ) Downstream Manhole, TC=91&53
Residential FFE - 9.0' = Basement FFE (912.1 ) per record drwg. REVISION #1 yy??77
Driveway Slope = 2.0% Note: The contractor is to maintain a REVISED PER ?74?y°
PLANS RECEIVED
minimum distance of ton feet (101 VIA EMAIL 0
between the sanitary sewer and water Vb07.0081846 Assumed North
fine faterals. 10-23-07 AN1A Scale 30'
YH(713
TC=91&53
PER RECORD
ORAMNG
I '
1 30.0' I I I uX I I
YHfn5 I 9_6 t
PTER91Or,'piD I >o I 919.5 919.8 128.03 91 i
DRAPING ?7 co ? -?K -
•
io I 123 _ U
i <
cr I 8 ? e X
GROUND COVER CALCULATIONS: I 67' - 22.79 37.5'1 - r'
=
Drive = 937 SFt I "71
Public Walk =364 SF± 319.19 e I co
U $ = "' I a
I on
36
Private Walk =N/A SF3 Lit L. I I o l7
Seeding =4,945 SFt p
Sod =305 SYt, 10 Q N 1 26.0' 7 p
from front of residence. C)
NOTE: GARAGE F.F.E. IS IY 2 1 s
} VL m J
PROPOSED TO BE 1.1' ABOVE Q m 1 N 1 31.8'
CURB AT DRIVEWAY T.B.M. 1
cn ? I Y m
I I I 52.71 s. J sn
Tv1 15.0' 17.0' c=iSr
1 (/7 1 I 15' R.D.E. g
FLOOD HAZARD STATEMENT
2 915.5
CERTIFICATION 92 I 920. 128.1
I>?e API L -
O\\\1Up1111111I1 11 111111/0 j7//j 1:710 I 15' R.D.E.
?????G\S 7ER'•Udj/A
o? No.e
S0303
STATE OF -
URI
This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on
this plot plan is subject to map scale uncertainty and to any other
uncertainly in location or elevation on the referenced flood insurance rate
mop (FIRM). ALL of the within described land DOES NOT LIE within that
special flood hazard zone 'A', as said land plots by scale on Community
Map Panel j 1800810001C of the flood insurance rate maps (FIRM) for
Hamilton County, Indiona, Dated May 19, 1981.
Z
0
4.7 SLOPE -? 4.,V S<-OPE
SCANNED TYPICAL SWALE SECTION
NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE
(25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTYF FIVE
(35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN
ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS
TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE
26.1.1.