HomeMy WebLinkAbout08010034 Sewer/Water Permit/sPermit Type
Subdivision
Section Number
Lift Station
Treatment Plant
Builder
Phone Number
Parcel Acreage
EDU in Gallons
Invoice Number
Final Lot Number 17
Long Ridge Estates Address Number 13728
1 Address 2
14 Austin Oaks Station Street Monique Dr
CTRWD WVVTP City Westfield
Pulte Zip Code 46074
3175752350 County Harri'tcn
310
Application Fee
Local Sewer Charge
Plan Review and Inspection
EDU Fee
Interceptor Fee
Fees Due
$100.00
$1,650.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like-, caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH LRE-822 LRE-821 C
Grease Trap No Slab Foundation No Lid Elevation 911.62 ft 911754 ft
Grit Interceptor No Crawl Space No First Floor Elevation 914.30 ft 914.30 ft
Grinder Station No Basement Yes Basement Elevation 904.50 ft 904.50 ft
Calculation is based on both Manhole lad Elevations and the elevation of the First Floor I 2.68 2.761
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met Connection to the sanitary sewer is now permitted.
CTRIJAIL
.
By signing below, I attest that I am familiar with the ' ric ' ecifications and agree to accept responsibility for all work done under this
Builder /Owner Signature Phone Number
Printed Name _-5- ?? ffAls
Permit Date 1/1112008
Revised 02108 Permit is valid for ONE-YEAR from the dale issued. Permit valid only with CTRWD seal in red ink.
Residential SANITARY SEWER PERMIT
OW69 INDIVIDUAL LOT/ EXISTING BUILDINGS
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR 11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at http:/Iwww.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10109107
Gar. FIFE = 912.5 PARKVIEW - ELEV I "BASE HOUSE STANDARD FEATURES"
1st Flr FFE = 914,3
TOW = 913
3 LEFT HAND - Full Brick
9' FULL BASEPdENT
.
Bsmt FFE = 904
5 FULL BSMT - 9' Walls 3 CAR SIDE ENTRY GARAGE
.
Drive Slope = N/A 3 CAR - Side Entry
Wd Deck "3" BRICK 3 SIDES
PATIO
"SELECTED FEATURES"
Ni??DlSo 1 II = 00
Min Front yard - Variable
Min. Between Residences - 6'
Min. Rear Yard - 20'
Flood Hazard Note:
BRICK 4 SIDES
DECK'S'
(3) 04 WINDOW WELLS
v N ,v
Note:
Contractor should verify site specific information cepided
hereon with the approved construction plans for this
development. Also, Contractor should reference Architectural
plans for foundation orientation and dimensions.
Note:
Lot Number 17 lies vcdhin Flood Hazard Zone "X" per the
scaled location on the Flood insurance Rate Maps for The proposed construction grades, contours, and proposed structure
Hamilton County, Indiana (Community Panel #18057C0205F, elevations as depicted hereon are basec upon information provided
dated February 19, 2003). upon the approved construction documens prepared for this
Note: development. Unless otherwise stated hereon, no information
pertaining to but not limited to, fluctuating water tables elevations,
This drawing is based upon construction plans andlor recorc soil types, and conditions within the build ng areas of this
development have been provided and for referenced on said
drawings prepared by others and is not based upon a field survey. documents. With the excavation of the proposed structure
COOR ConsulUng & Land Services. Corp. does not warrant the foundations, certain care and observations should be made in regard
correctness or integrity of this information. The contraclorlowner to such conditions as soil types and fluctuating water tab es_ During
should verify existing conditions prior to construction Any varying the excavation process should any unsuitable soils or ground water
field conditions or any discrepancy w,th the information contained be witnessed, the builder shall be immediately notified fc• further
hereon should be immediately reportec to COOR Consulting & Land examination and consultat on At the builders discretion, additional
Services. Ccrp failure to do so would result in the contractorlowners construction techniques may be necessary to alleviate future
assumption of liability. prob,errs.
^,. MODEL HOME
o?fomoKKMln Dated Hsu"Ja k(i)Q39
*0 00 Fj'?
303 VVEST MAIN STREET KNIGHTSTOWN. INDIANA
888) 593-2667 (765) 345-5943 FAX;: (765) 345-5692
LONGRIDGE ESTATES
SECTION ONE
PC 3, SLIDE 725
INSTR tQ00500063316
LOT # 17
13728 MONIQUE DRIVE
WESTFIELD. IN 46074
R
CITY OF CARMEL
Item 1 of 1 PERMIT RECEIPT
Sec:19 Twp:18 Rng:03 Sub:LRE Blk:1 Lot:17
PARCEL ID ........: ZLRE17
DATE ISSUED.......: 01/11/2008
RECEIPT #.........: 27171
REFERENCE ID # ...: 08010033
SITE ADDRESS .....
SUBDIVISION ......
CITY .............
IMPACT AREA ......
13728 MONIQUE DR
LONGRIDGE ESTATES
WESTFIELD
OWNER PULTE HOMES
ADDRESS 11590 N MERIDIAN ST
CITY/STATE/ZIP CARMEL, IN 46074
OPERATOR: vdolan
COPY # : 1
RECEIVED FROM ....: PULTE HOMES
CONTRACTOR .......: LIC # XA-1SUP
COMPANY A-1 SUPERIOR EXCAVATING
ADDRESS ..........: 31143 ROSEWAY DR
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46226
TELEPHONE ........: (317) 898-0767
FEE ID -TNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW SAL
---------- ------------- ---------- ---------- ---------- ---------- ----------
USFWATCONN FLAT RA'Z'E 1.00 1396.00 0.00 1396.00 0.00
TOTAL PERMIT - -1.396.00 0.00 1396.00 0.00
-
METHOD OF PAYMENT
-----------------
CHECK
TOTAL RECEIPT :
AMOUNT
------------
1396.00
-----1396.00
NUMBER
------------------
0050516620
°`r'"w CITY OF CARMEL / CLAY TOWNSHIP
WATER / SEWER PERMIT / RECEIPT
',INGuKFi
PERMIT TYPE: USEWRWATR ; SEWER/WATER PERMIT
PARCEL ID #: ZLRE17
LOT & SUBDIVISION: 17 LONGRIDGE ESTATES
ADDRESS OF CONSTRUCTION: 13728 t`,lIONIQUE CSR WESTFIELD, IN 46074
PAYMENT RECEIVED FROM:
Name: PULTE HOMES
CHECK #: 0060516620
EXCAVATOR INFORMATION;
Name: A-1 SUPERIOR EXCAVATING
Ph. #: (317) 698-0767 Fax #: Email:
Street Address: 31143 ROSEWAY DR INDIANAPOLIS, IN 46226
Bond Expiration:
Permit #: 08010033
Date: 0111112008
The building & Sewer Shall be pvc sewer pipe meeting AST M specifications 3034 SDR 35 of latest revision: or vitrified clay pipe, meeting
AST-M specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTM 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations sha
in strict compliance with pertinent City of Carmcl ordinances. Back Water check valves shall be installed in accordance with City Code Sect
9-122(a), and sections P3008.1 and .2 of the Intemational Residential Code. All building sewers shall be 6" diameter.
All installations shall be "open trench" inspected and approved by the Carmel Sewer Department before any backfilling is done. Iv<
Compliance may result in digging up the sewer installation and"or denial of future sewer permits andior denial of water connections.
No inspections or installations will he made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance,
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any
muct he curt- a senarate street clot nermit shall he ohrnined.
PAYMENT RECEIVED BY:
FEES:
$1,396.00