Loading...
HomeMy WebLinkAbout08010014 Site PlanSchnWas bowertall fie Sdmdder corporstloo 6001 We Awmoe 31sr- sg Historic Fort Nwrrwm IJwdeaa" ArewActoae Iedlea"ft bam 18816-IM7 Qs • LLR 917-826-7100 Ceolae 917-826_7200 FAY This Plat Plan Prepared For: MA Hamel Lot # 39, contoining10,194 S.F.t, in Plot Plan Legend Heather Mai ® Proposed Grades Swum i# 1 000.0 Existing Grades klstrunlent #200500003045 --000.0- Contour Grade P.C. 3r SM 560 * Approx. Lateral Location Towmh , Hamiton Count 8- Sanitary Sewer Lines Clay lr aR storm sewer Lines SEC 20. Tim RM v Water Service Lines C.A. Su f Dr ' L' 14249 Camden Lane Westfield, IN 46074 Prepared Date: 01/04/08 Community Restrictions: Side Yard = 3' min. Aggregate = 6' B.H. Zoning - St race om mss ( 50' R/W) • Manhole (Sanitary or Storm) Beehive Inlet (Storm) 8 AMH Y D Curb Inlet (Storm) End Section (Storm) Fire Hydrant Flow Line of swale Building Line (BL / BSL) - - - - - - - - Easement Line M/I HOMES Pad Grade = 918.1 per plan Pad Grade + 0.2' = Garage FFE (918.3 ) Garage FFE + O.5 = Residential FFE (91118 ) Residential FFE - 9.0 ' = Basement FFE (909.8 ) Driveway Slope = 2.8% NOTE: GARAGE F.F.E. IS PROPOSED TO BE 1.0' ABOVE CURB AT DRIVEWAY T.B.M. tr tl--li Note: Sanitary Sewer Tap of Costing Information Upstream Manhole, TC= 917.54 Downstream Manhole, TC= 916.98 per record drawing e FLOOD HAZARD STATEMENT CERTIFICATION 1 S0303 STATE OF This drawing is not int ded Ttoeepresented as a retrocement or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this plot plan is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced hood insurance role mop (FIRM). ALL of the within described land DOES NOT LIE within that special flood hazard zone 'A as sold land plots by scale on Community Map Panel E 1800810001C of the flood insurance rote maps (FIRM) for Hamilton County, Indona, Doted May 19, 1981. s Note: This droving is based on construction plops or record drawings, and is not hosed upon o field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; failing to do so results in the contractors assumption of all liability. Note: The boseno t devotion. depicted hereon, has been dole mvired and based on the pod grades and/or contours taken Tram the construction piers for the subdivision. U 'Pot slated, no nformotian about flocW** water babies, soil coadlllora, or »i I%= has been provided or doted an said pions. This lot is located now a body of water. Lot or sail card iom nay require that the bon w t floor elevation be held 2 loot above normal pod devotion. Site nvewt4otion may he needed 0 voter is encountered during the excavation process or if other loam water devotion or soil condi ions we present investigation and any remedial procedures is of the discretion of the builder to determine and take appropriole slaps of action. II any grand voter is encountered during excavation the builder is encouraged to contact The Schneider Carporation to discuss pos,ble corso of action. NOTE: SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. Note: Builder to ensure positive drainage away from structure(s). LOT# y3??9??p? °m° V".0089N Assumed North Scale : 1, = 30' GROUND COVER CALCULATIONS: Drive = 632 SFt Public Walk =247 SFt Private Walk =n/o SFt Seeding = 5,003 SFt Sod = 309 SYt, from front of residence. Note: The contractor is to maintain a mini num distance of ten feet (107 between the sonitary sews and water line lateral. Il?r / 43.6• 41 Op / ,`'? G ?QQ P O CO,'` / J 4\, 4111 ,?00 4: T S ? 4 1 ?ppE TYPICAL SWALE SECTION NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DVIELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.