Loading...
HomeMy WebLinkAbout08010066 Site Pland 9' FULL BASEMENT 2 CAR FRONT ENTRY GARAGE GARDEN ROOM PATIO (2) 4X4 VIONDOW WELLS & (1) 2 WINDOW WELL / 3 CAR FRONT ENTRY GARAGE BRICK 4 SIDES MA5TER & MOCK BAYS DECK A" 6f 1)4X4 'vVIN00W 'dVELL$ 4 fyD+%-t ?tt5 Lot Number 309 lies within Flood scaled location on the Flood Insu Hamilton County, Indiana (Corrrr dated February 19, 2003). STM INLET TC=781.4 7 This drawing is based upon const tion plans ror record drawings prepared by others and is n upon a field surrey. COOR Consulting & Land Services. Corp. does not warrant the correctness or integrity of this information. The contractoriowner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.: failure to do so would result in the contractor/owners assumption of liability. oor.. Gar. FF`` = 782.2 HUNTCLIFFE - ELEV 6C 1 st Fir FFE - 784.0 RIGHT HAND - Full Brick TOW = 783.0 FULL Il - 9' Walls Bsmt FFE = 774.2 .3 CAR - Front Entry Drive Slope = 9.8% I Deck "4" LOT ## 309 ±13,197 SF LINZ 7 G?C]G'?'ot`9 C?OCrn???f?rG?C? IJ @) T 1?3.I L• U t1 LJ LI 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX9: (765) 345-5692 DATE: 01110f08 JOB If2003-100.309 REVISIONS: SAN MH 765 TC=780.84 Contractor should verify site specific information depicted hereon with the approved construction plans for this development. Alse, Contractor should reference Architectural plans forfoundation orientation and dimensions. The proposed construction grades, contours, and proposed structure elevations as depicted hereon are based upon information provided upon the approved construction documents precared for this development, Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and eondAions within the building areas of this development have been provided and for referenced on said documents With the excavation of the proposed structure foundations, certain care and observatlons should be made in regard to such conditions as soif types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witnessed, the builder shall be immediately notified for further examination and consultation At the builders discretion, additional construction techniques may be necessary to alleviate future problems. 93RI--c?1TILd)[ill C-03 Ill #200600034032 PC 4, SLIDE 61 LOT # 309 14280 ARCADIAN CIRCLE CARMEL, IN 46033 Pulte Homes of Indiana Note: Minimum Front yard - 25' Minimum Side Yard - 3' Minimum Aggregate - 6' 1,13etween Houses) Minimum Rear Yard - MIA