HomeMy WebLinkAbout08010087 Sewer/Water Permit/s00777 INDIVIDUAL LOT 1 EXISTING BUILDINGS
Permit Type Final Lot Number
Subdivision Lakes at Towne Road Address Number
Section Number 2 Address 2
Lift Station 2.3 126th Street Station Street
Treatment Plant MIX City
Builder Paul Shoopman Home Building Group Zip Code
Phone Number 317-415-0459 County
34
- 2584
Diamond Lake Dr
Westfield
46074
Local Sewer Charge
Plan Review and Inspection
Application Fee
Parcel Acreage
EDU in Gallons
Invoice Number
310
EDU Fee
Interceptor Fee
Fees Due
$100.00
$1,650.00
$1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe- NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH LTR-711 LTR-71o DSMH
Grease Trap No Slab Foundation No Lid Elevation 909.21 ft 910.29 ft
Grit Interceptor No Crawl Space No First Floor Elevation 912.60 ft 912.60 ft
Grinder Station No Basement Yes Basement Elevation 903.10 ft 903.10 ft
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor ` 3.39 2.31
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met. Connection to the sanitary sewer is now permitted.
?o0 ,0%p•NA H4.t!jz Oy
? n.
`? GG
{
CTR?r
l J
By signing below, 1 attest that I am familiar with the District's s eclfications and agree to accept responsibility for all work done under this permit.
Builder / Owner Signature V__ e? oh .? Phone Number
Printed Name
Permit Date 1118/2008
Revised 1WO8 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink,
Residential SANITARY SEWER PERMIT
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank"... shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at http:/twww.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10109/07
PLOT PLAT-T
DRAWING NOT' TO BE SCALED - DIMENSIONS PREVALENT
PROPOSED FINISHED FLOOR ELEVATION HOUSE : 912.6
PROPOSED FINISHED FLOOR ELEVATION GARAGE : 910.9
PROPOSED FINISHED FLOOR ELEVATION BASEMENT : 903.1
000.0 - PRECONSTRUC17ON GRADE
000.0 " PROPOSED GRADE
DRNG. FLOW
SOD: 1,300± Sq. Yds.
Hydroseed Area: 0,000 ± Sq. Ft.
HOUSE WALK : 413 ± Sq. Ft.
DRIVE/APRON : 2,148 ± Sq. Ft.
CITY WALK : 740 ± Sq. Ft.
PATIO/STOOP : 120 ± Sq. Ft-
SERVICE DOOR STOOP : 12 ± Sq. Yds-
NOTE:
VERIFY SANITARY LATERAL LOCATION
PRIOR TO DRIVE CONSTRUCTION.
Model : HOOVER
Elevation "A"
100% Full Front Brick Ledge (See Sales Brochure)
No Extensions
Fireplace W/ O.C.
Add Stone To Chimney Chase
Washed Aggregate Front Porch, Rear Patio,
... & House Walk
Front Porch With Footings
Basement Option # 2 (9' walls)
CA.010
VAR DU & S.S.E.
& L M.A_E.
9'9.?
a' s' Ts:
?F
1 `
Z Scale. 1 - 30'
Job No. 08-0002
Date: 1-15-08 J
Drawn By : SAR
CAUTION:
INSTALL SANITARY & WATER
LATERALS PRIOR TO EXTERIOR
CONCRETE CONSTRUCTION.
r 4
c:
HAMILTON COUNTY, INDIANA
^5$4 DIAMOND LAKE DRIVE
Zoning: lO' N-Iin i }' A* - 20' Rcar
CA. # 10
910.7 VAR. DU & S S.E
and _ N 7c? & L M.A.E
/ - r 910.3
Lot 34
910.0
16.224 Se. Ft.
r?
910.0
Hyd
st.ver
kff
NOTE: -
rr SHAD RE'IM RESPONSWC r T OF THE BUILDERJCONTRAC *0R
To VERIFY THE13LMDMDMENSIONS,BUILDV4GLOCATIONS,THE
Copyright 2007-
LOCATION OF onim PERTWQJT FEATURES, LLEVAMNS, AND ALL Paul Shoopman Home Building Group, Inc„
UNDER GROUND L'tRIM (HOLEY MOLEY I-MMM-'5441 PRIOR TO Indianapolis, IN USA-
A I C SCALE r?
STARTOFCONSTRUtTION. TIM DM dDEDUSEOFTHLSPLOTMANT
TIE
P
MITS ONLY
ND S
BE All Rights Reserved NOTE:
IS FOR SWL?XNG B" WO
ER
A
HALL NOT THIS DRAWING IS NOT INTENDED TO BE RE
USED FOR ANY OTHER PURPOSE AS A RETRACEMENT OR ORIGINAL HOUND
NOTE : A ROUTE SLRVEY OR A SURVEYOR LOCAT
All homes have a brick ledge on the front of the home. However, note,
although the brick ledge will be there, it does not represent that brick will be
m
automatically installed. Cross hatch lines will show brick ledge. Again, note brick
imr
=
only goes where arrows show brick. , L I
0, ! A
b I -t-50
LTe 0
6
a
6
ri
r
Proposed
Diva
2.f
Proposed
Residence W
(OF
[V
CV
p
903,2
a
. 16'0'
34
'0 910.7 O
?
rn
ec
The Green Sheet however will have arrows to show exactly where and if brick is to
be installed. Plot plan dimensions however do show brick ledge dimensions. Pay
close attention to where brick is to be installed. It's the responsibility of all contractors
to note these items and install correctly.
CITY OF CARMEL
Item 1 A 1 PERMI_ RECEIPT
Sec:29 Twp:18 Rng:3 Sub:LTR Blk: Lot:34
PARCEL -2 ........: 1709290016008000
LATE =SSUED....... : 01/22/2008
RECEIPT #.........: 27243
REFERENCE ID # ...: 08010086
OPERATOR: Flux
CO PY 4 : I
SITE ADDRESS .....: 2584 DIAMOND LAKE DR
SUBC:V:S:CN ......: LAKES AT TOWNE ROAD, THE
CITY ............. : WESTFIELD
IMPACT AREA .......
OWNER ---- .... : PAUL SHOOPK N
ADDRESS __ ......: 8221 NORTHWEST BLVD
CITY/STA7E/ZIP ,,.: INDIANAPOLIS, IN 46278
RECEIVED FROM .... : PATJL SHOOPMAN BUILD!
CONTRACTOR ....... : LIC 4 XRREXCA
COMPANY .......... : R & R EXCAVATING PLUS
ADDRESS ........ : 4375 N CC'UNTY RD. 1000 E
CITY/STATE/ZIP ... : BROWNSBURG, IN 46112
TELEPHONE ........ : (317) 852-4680
FEE ID
---------- UNIT QUANTITY
------------- -------- AMOUNT PD-TO-DT
-- ---------- ---------- THIS REC
----------
USFWATCONN FLAT RATE 1. 00 1310.00 0,00 1310.00
UWATERTAP FLAT RATE 1. 00 86,00 0.00
---- 86.00
-----
TOTAL PERM
IT ---------- ------
1396.00 0.00 -----
1396.00
METHOD OR PAYMENT AMOUNT
-- NUMBER
-------
----------
CHECK ------- ----------
1396.00 -----------
2265
TOTAL RECE IPT : 1396.00
NEW BAT,
0.00
0. co
0.00
>s f- . CITY OF CARMEL / CLAD` TOWNSHIP Permit #: 08010086
WATER / SENVER PERMIT / RECEIPT Date: 01/2212008
PARCEL ID #: 1709290016008000
LOT & SUBDIVISION: 34 LAKES AT TOWNE ROAD THE
ADDRESS OF CONSTRUCTION, 2584 CIAMOND LAKE DR WESTFIELD, IN 46074
PAYMENT RECEIVED FROM:
Name: PAUL SHOOPMAN BUILDI
CHECK #: 2266
EXCAVATOR INFORMATION:
Name: R & R EXCAVATING PLUS
Ph. M (317) 852-4680 Fax #: Email:
Street Address: 4375 N COUNTY RD. 1000 E BROWNSBURG. IN 46112
Bond Expiration:
PERMIT TYPE: USEWRWATR ? SEWERIWATER PERMIT
Special Notes/Conditions:
LOT 34 LAKES AT TOWNE LOAD, WATER PERMIT
'NO NOTES
The building & Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting
ASTMt specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTM 2331 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All imtallabons shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.I and .2 of the International Residential Code. All buildiaa sewers shall be 6' diameter.
All installations shall be "open trench' inspected and approved by the Carmel Sewer Department before any back-filling- is done. Non-
compliance may result in digging up the sewer installation and'or denial of future sewer permits and%or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sewer inspections should be requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE.. if any street
must he cut, a Senarme Street cul nermit Shah he obtained
APPLICANT NAME: RL GROCE
PAYMENT RECEIVED BY:
FEES:
$1,396,00