HomeMy WebLinkAbout08010090 Sewer/Water Permit/sPermit Type
Subdivision
Section Number
Final
Lakes at Towne Road
1
Lift Station 23 126th Street Station
Treatment Plant MIX
Builder Paul Shoopman Home Building Group
Phone Number 317-415-0459
Parcel Acreage
EDU in Gallons
Invoice Number
310
Lot Number 22
Address Number 2610
Address 2
Street Wineland Creek Dr
City Westfield
Zip Code 46074
County Hamilton
Local Sewer Charge
Plan Review and Inspection
Application Fee $100.00
EDU Fee $1,650.00
Interceptor Fee
Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional W aste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundatio n
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer syste m. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permi t.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH LTR-704 LTR-703 DSMH
Grease Trap No Slab Foundation No Lid Elevation 911.37 ft 912.62 ft
Grit Interceptor No Crawl Space No First Floor Elevation 915.00 ft 915.00 ft
Grinder Station No Basement Yes Basement Elevation 905.50 ft 905.50 ft
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 3.63 i 2.38
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
,4_ ` Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met. Connection to the sanitary sewer is now
CTRW'D
U
Q?
'ysy?pRFG; ONAL,n,P`'?
By signing below, I attest that I am familiar with the District' specifications and agree to accept responsibility for all work done under this permit.
Builder / Owner Signature t?& Phone Number
Printed Name Z Cis
Approved By Permit Date 1/1812008
Candy J. Feltner, Dirmfor of Administration & Customer Service
Revised 112108
Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SCANNED
Residential SANITARY SEWER PERMIT
00774 INDIVIDUAL LOT ! EXISTING BUILDINGS
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "... shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at http://www.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10/09/o7
0 Y- Y
PLOT PLAN
DRAWING NOT TO BE SCALED - DIMENSIONS PREVALENT
PROPOSED FINISHED FLOOR ELEVATION HOUSE : 915.0
PROPOSED FINISHED FLOOR ELEVATION GARAGE : 913.3
PROPOSED FINISHED FLOOR ELEVATION BASEMENT : 905.5
000.0 - PRECONSTRUCTION GRADE
000.0 - PROPOSED GRADE
- > DRNG. FLOW
SOD: 570 ± Sq. Yds.
Hydroseed Area: 5.969 ± Sq. Ft.
HOUSE WALK : 65 ± Sq. Ft.
DRIVE/APRON : 1.042 ± Sq. Ft.
CITY WALK : 434 ± Sq. Ft.
PATIO/STOOP : 123 ± Sq. Ft. W/ Steps
SERVICE DOOR STOOP : 12 ± Sq. Yds
VERIFY SANITARY LATERAL LOCATION
PRIOR TO DRIVE CONSTRUCTION.
C.A # 8
VAR. D.U & S S E.
& ? M A E
O
z
91'
Scale: 1" = 30'
Job No. 08-0001
Date: 1-15-08
Drawn By : SAR
M H_ #_70`?? V
CAUTION:
INSTALL SANITARY R WATER
LATERALS PRIOR TO EXTERIOR
CONCRETE CONSTRUCTION.
NOTE:
IT SHALL BE THE RESPONSUMM OF THE BUR.DERAWTRACrOR
TO VERIFY TIM BLTLDLNG DWENS10NS. BLTILDM LOCATIONS. THE
LOCATION OF OTHER PFRTINIM FEATURES, ELEVATIONS, AND ALL
UNDER GROUND UTILITIES (HOLEY MOLEY I.804362-5544)PRIOR TO
THE START OF CONS MUCITON. THE MENDED USE OF THIS PLOT PL
IS FOR SECURING BU[LDM PERMITS ONLY AND SHALL NOT BE
USED FOR ANY OTHER PURPOSE.
O A
4+ 19
@s B ?Oz
°UN
?S
LOT # 22
Lakes (k Towne Road
SIJ A W\ ONE.
HAMILTON ('01-NTY. INDIANA
26:'0 NN 1\1 I %AU r RA l:h DRIVF
Yoninr: 10 Min ! 210' Azg - ^-0 Rear
Model : GARFIELD
Elevation "A"
100% Full Front Brick Ledge (See Sales Brochure)
Brick Per Plan
4' Depth Ex. Thru Nook
No Fireplace
Add Garage Service Door w/ 3'x 4' Stoop
Front Porch With Footings
Basement Option It 2 (w/ 9' Walls)
15'RD &UE
O
Lot 22 O
13.533 Sc Ft 100
18'
1
14'
1
Conc
1
v Pats N .i 912.9
25'1 ' o
6'4-1;2" Lot 21
911.7 0 g
913.1 ° - Pad Elev =9 t 2 90
21 1,-" =n
Proposed 913.1 0 ?
v Residence 9114 < O
913.1 O
911.3 74'
.0 ?
O
3
1 22 " C
91
.
'0, P
d 20.o O
9 rcpese
X5'4" Drive Z
VAR B L
-+ $ 1 VAR D U &SSE
D
1 Sanft
` y Sewer N cm)
Flo As-8,4 =. COn -c4-
J 1 Elec
? Location
? B asrc R;r?
Ce1w
were
1
5' dewa ?.
911
9
69 .
4.
102 cv
Sump Pump
?30
Copyright 2007-
Paul Shoopman Home Building Group, Inc.,
Indi 1' IN USA
L?
SCANNED
?, 1 1 ?C'
anapo ts, - GRAPH C SCALE IN FEE-
All Rights Reserved NOTE:
THIS DRAVvTNG IS NOT INTENDED TO BE REPRESENTED
AS A RE1R4CEMENT OR ORIGINAL. BOU14DARY SURVEY.
A ROUTE SURVEY OR A SURVEYOR LOCATION REPORT.
All homes have a brick ledge on the front of the home. However, note,
although the brick ledge will be there, it does not represent that brick will be
automatically installed. Cross hatch lines will show brick ledge. Again, note brick
only goes where arrows show brick.
The Green Sheet however will have arrows to show exactly where and if brick is to
be installed. Plot plan dimensions however do show brick ledge dimensions. Pay
close attention to where brick is to be installed. It's the responsibility of all contractors
to note these items and install correctly.
CITY OF CARMEL
Item 1 of 1
PERMIT RECEIPT
OPERATOR: pl
ufl,
COPY # 1
Sec:29 Twp:18 Rng:03 Sub:LTR Blk:l Lot:22
PARCEL ID ........: ZLTR22
DATE ISSUED.......: 01/22/2008
RECEIPT #.........: 27248
REFERENCE ID # ...: 08010088
SITE ADDRESS .....: 2610 WINELAND CREEK DR
SUBDIVISION ......: LAKES AT TOWNE ROAD, THE
CITY ............. : WESTFIELD
IMPACT AREA ......
OWNER ........
ADDRESS ..
CITY/STATE/ZIP
RECEIVED FROM
CONTRACTOR ...
COMPANY ......
ADDRESS
CITY/STATE/ZIP
TELEPHONE ....
PAUL SHOOPMAN HOMES
8227 NORTHWEST BLVD
INDIANAPOLIS, IN 46278
PAUL SHOOPMAN, BUILD
LIC # XATKEXC
ATKINS EXCAVATING INC
9110 HUGGIN HOLLOW RD
MARTINSVILLE, IN 46151
(812) 422-9467
FEE ID UNIT QUANTITY AMOUNT PD- TO-DT THIS REC NEW BAL
---------
---------- -----------
USFWATCONN FLAT RATE -- ----------
1.00 ---------- ----
1310.00 ------
0.00 ----------
1310.00 -
0.00
UWATERTAP FLAT RATE 1.00 86.00
--- ---- 0.00
------ 86.00
---------- - 0.00
---------
TOTAL PERMIT -------
1396.00 0.00 1396.00 0.00
METHOD OF PAYMENT AMOUNT
---
-- NUMBER
---------------
---
----------------- -
CHECK ---
---
1396.00 2270
TOTAL RECEIPT : 1396.00
SCANNED
CITY OF CARMEL / CLAY TOWNSHIP Permit #: 08010088
f WATER ! SEWER PERMIT J RECEIPT Date: 01/2212008
PARCEL ID #: ZLTR22
LOT & SUBDIVISION: 22 LAKES AT TOWNE ROAD, THE
ADDRESS OF CONSTRUCTION. 2610 WINELAND CREEK DR WESTFIELD. IN 46077
PAYMENT RECEIVED FROM:
Name: PAUL SHOOPMAN, BUILD
CHECK #: 2270
EXCAVATOR INFORMATION:
Name: ATKINS EXCAVATING INC
Ph. #: (812) 422-9467 Fax #: Email:
Street Address: 9110 HUGGIN HOLLOW RD MARTINSVILLE, IN 46151
Bond Expiration:
PERMIT TYPE: USEWRWATR ; SEWERIWATER PERMIT
Special Notes/Conditions:
LOT 22 LAKES AT TOVIINE ROAD, WATER PERMIT
NO NOTES *
The building & Sewer Shall he pvc sewer pipe meeting ASTNI specifications 3034 SDR 35 of latest revision; or vitrified clay pipe. meeting
ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shat be installed in accordance with ASTM 2321 for pvc pipe and the Uniform I'iumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmet ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(x). and sections P3008.1 and .2 of the International Residential Code All building sewers shall be 6" diameter.
All installations shall be -open trench- insnected and approved by the Carmel Sewer Department before any backfiltiy is done. Non-
compliance may result in digging up the sewer installation andior denial of future sewer permits and'or denial of water connections.
No footing or Inundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer
Sewer inspections should he requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be matte on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sever (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If an., street
must he cut- a sennrate ;Lreel cnt nermit shall he ohlained.
APPLICANT NAME: RL GROCE
PAYMENT RECEIVED BY:
FEES:
$1,396.00
SCANNED