HomeMy WebLinkAbout08010078 Site PlanSCN,6kw
11,e Sotmdder Cmpomllon h&ft iq
8001 OUR Avenue Suneyta6
Historic Fart HuTieon landscape kchK ature
Indienepol* Indlsm 48216-1097 G19 • US
917-826-7100 Gedop
917-826-7200 FAX
This Plot Plan Prepared For R.H. of
Lot # 240 , containing 10,241 S.F.t,
Claytloume
Section # 3
INSTR. # 2x0400080247
P.C. 13, SI'Nie # 533
Hampton County, Clay Up
See 30, T18N, RM
4046 Teague Place (50'R/W)
Carmel, IN 46074
Prepared Date: 01/23/07 : By. AMA
Proposed Wyer(a : INVENTORY HOME
Community Restrictions:
Side Yard = 5'
Rear Yard = 20'
Aggregate = 10' (B.H.)
Zoning = S1
IIIY NIY ® Proposed tirades
in 000.0 Existing Grades
000.0- Contour Grade
* Approx. Lateral Location
! Sanitary Sewer Lies
R Storm Sewer Lines
v Water Service Lies
- - - - Sub-Surface Drain Lines
• Manhole (Sanitary or Storm)
Beehive Inlet (Storm)
Curb Inlet (Storm)
D End Section (Storm)
Ak Fire Hydrant
F
- • • • - • • • -
low Line of swale
Building Line (BL / BSL)
- - - - - - - Easement Lie
R.H. of Indiana
Finished Floor Elevation Information
Pad Grade = 916.3 per plan
Pad Grade + 0.7' = Garage FFE (917.0 }
Garage FFE + 1.5' = Residential FFE (910)
Residential FFE - 9.0' - Basement FFE (909.5)
Note : The garage finished floor elevation
is 2.6' above the curb at the drive, per plan.
Ground Cover Calculations:
Drive = 797 SFt
Public Walk =319 SFf
Private Walk =92 SFt
Hydroseeding =4,307 SFt
Sod = 331 SYt , from
Rear of residence
Optional Sod Package
Hydroseeding =736 SFt
Addl. Sod Pkg.= 391 SYt,
Rear easement.
Sidewalk to be placed
1' from property line,
4' from back of curb.
per plan-
REVISION 12
REVISED SUNROOM TO
SCREEN PORCH
1/15/08 AMH
REV 11
NEW ELEVATION
VDD&0084656
1/14/08 TLC
Note: Per Carmel zoning ordinance 26.1.1 : The
residential district limits height to twenty-five feet
(25?, however a dwelling may be Incremed in
height to thirty-five feet (35) provided the side
and rear yards are increased an additional one
foot (1') for each one foot (1') the structure
exceeds the first twenty-five feet (251 in height
Note: Sanitary Sewer
Top of Costing Information
Upstream Manhole, TC=914.95
Downstream Manhole, TC=914.51
per record drawing
Note:
The contractor is to maintain a minimum
distance of ten feet (11) between the
sanitary sewer and water line laterals.
This drawing is not intended to be represented as a n
original boundary survey, a route survey, or o Surveyor
Note:
This drawing is based on construction plans or record
drawings, and is not based upon a field survey. The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately, failing to do so
results in the contractors assumption of all liability.
Notes
The basement elevation, depicted hereon, has been determined and
based on the pod grades and/or contours taken from the construction
plan for this subdivision. Thiess stated, no Information about
fluctuating water tables, sod caditiorM or will types has been
prodded or dated on said plans. This lot is located now a body of
water. Lot or sad condition may require that the basement floor
elevation be held 2 foot above normal pod elevation. Site Investigation
may be needed H water Is encountered during the excavation process
or if other know water elevation or soils conditions are present
Investigation and any remeQal procedures is at the discretion of the
builder to determine and take appropriate ape of action. If any
ground water is encountered during excavation the budder Is
encouraged to contact The Schneider Corporation to discuse possible
courses of action.
Note: Sump pump(s) to be
placed by budder as needed. Lot 240
Vb07.0067371
s:
TYPICAL §&9- SECTION
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale an flood Insurance rate map #180081 0205 F for the City of
Carmel, Indiana dated February 19, 2003.
SIGNATI:?E nA,-
SIGNA',- ?_ _?t ? ,Jh- M4? JI• 1 ??a=i _.,? r' ?.'? ?. ?.. ???1E.''. -
o?o
Detail of Ground/ Storm
Water flow pattern for
individual lots.
Note: Budder to ensure positive
drainage away from structure(s).
FLOOD HAZARD STATEMENT
CERTIFICATION
T