HomeMy WebLinkAbout08010096 Sewer/Water Permit/sPermit Type Final
Subdivision Cass Estates
Section Number S?Jt?
Lift Station 17 Zion Hills Station
Treatment Plant CTRWD VWVfP
Builder Paul Shoopman Home Building Group
Phone Number 317-415-0459
Parcel Acreage
EDU in Gallons 310
Invoice Number
Lot Number 18
Address Number 3965
Address 2
Street Andretti Dr
City Zionsville
Zip Code 46077
County Harri'tcn
Local Sewer Charge
Plan Review and Inspection
Application Fee $100.00
EDU Fee $1,650.00
Interceptor Fee
Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has:
USMH CE-716 CE-714 DSMH
Grease Trap No Slab Foundation No Lid Elevation 907.68 ft 907.31 ft
Grit Interceptor No Crawl Space No First Floor Elevation 909.20 ft 909.20 ft
Grinder Station No Basement Yes Basement Elevation 900.70 ft 900.70 ft
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 1.52 i 1.89
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met. Connection to the sanitary sewer is now permitted.
??O?,?p1ANA • Nq??/CA
h ?G
y
a
RWD <
•
\ . A?;
By signing below, I attest that I am familiar with the District's specifications and agree to accept responsibility for all work done under this
- ? ?,r.r6-Phone Number
Builder I Owner Signature!;/14
Printed N -?- ( C
Approved p____ Permit Date 1123/2008
Candy J. Feltner, Director of Administration & Customer Service
Revised 112/08 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRVVD seal in red ink.
Residential SANITARY SEWER PERMIT
00780 INDIVIDUAL LOT I EXISTING BUILDINGS
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO femco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at http://www_ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10109107
PLOT . PLAN
DRAwiNG NOT TV BE SCALED - DMIENSIOM PREVALENT
PROPOSED FINISHED FLOOR ELEVATION HOUSE : 909.2
PROPOSED FINISHED FLOOR ELEVATION GARAGE : 908.0
PROPOSED FINISHED FLOOR ELEVATION BASEMENT : 900.7
000.0 - PRECONSTRUCTION GRADE
000.0 - PROPOSED GRADE
> DRNG. FLOW
j - ELEC. METER
SOD: 349 ± Sq. Yds.
Hydroseed Area: 3,259 ± Sq. Ft.
HOUSE WALK : 280 ± Sq. Yds.
DRIVEiAPRON : 1,450 ± Sq. Yds.
CI'T'Y WALK : 370 ± Sq. Yds.
PATIO/STOOP : 80 ± Sq. Yds.
SERVICE DOOR STOOP : 12 ± Sq. Yds.
NOTE:
REFERENCE CERTIFICATE OF
CORRECTION: INSTR. # 200500067046
FOR CORRECTED BEARINGS AND
EASEMENTS ON MONTOYA DRIVE.
I QT # 18
C ass Estates
S ection 1
HAMILTON ( COUNTY, IiNDU
3965 Andretti Drive
ZONING ; SIDE 4' Min. REAR 29
Model : BRECKENRIDGE
Elevation "A"
100% Full Front Brick Ledge (See Note)
Brick Per Attached Plan
3rd Car Garage Option
2' Width Ext. Thru GR, BR 2, BR 3, & HBath
2' Width Ext. Thru BR 4 & Loft (BR 5)
2' Width Ext. Thru Basement
Fireplace W/ O.C.
Washed Agg. Front Porch, Rdar Patio, Service Stoop
... House Walk, Driveway Diamonds
Hardi-Plank
Front Porch With Footings
Basement Option # 3 (9' Walls)
CAUTION:
INSTALL SAN. LATERAL PRIOR
dretti Drive
50' R1W
(30' Pvmt.)
M H. A 716
T C 907 58 S 9°29' 2" 90.001-4
`S-P F-P E i ?. ..
"` co eao / i
Inv 896 31 anitary Sewer
'? a"PV Scne]-lad
D.L & S S.E
2 SL
ate'
,vas-,.,? ?
B
Q
Z
o `o -.r s _ n.o
906.9
807.6 T'' co 905.7
T &
w
O
9D7.8
N I
L? •7 Proposed
Pad Elev =907 5G I Proposed Drive
m
" Residence
'
"
' v ? I 1 C
Scale: 1
= 30 y 905.8
Job No. 07-0031
Lz
PC
907 B 9D4.s o
Date: 01-17-08
PUmp 907907 '
Sumo
Drawn By : SAR
2- 16.3-
4-4- _ _ ' r
1
'
'
> y
e
1
5
?,-veie Shoo
7' 2
14' Steps
O
M r
904.1 ?? 9Q4.6
C:)
p
Lot 18
Z 10.800 So Ft
903.8
C.R. # 6
VAR. D.&U E &
LV A.E &P A-E-
NOTE:
IT SHALL BE THE RESPONSIBIL.I Y OF TIE BUII.DFR&ONIR4CTOR
LOCATION OF OTHER PFRMENr FEATURES. ELEVATIONS. AND ALL
UNDER GROUND UTILITIES (HOLEY 610LEY I-$00-382.5544) PRIOR TO
THE START OF CONSTRUCiTON THE INTENDED USE OF THIS PLAT PLAN
IS FOR SECURING BUIDP W, PERt+M ONLY AN-D SHALL NOT BE
USED FOR ANY OTHER PLT.POSE.
Copyright 2007-
Paul Shoopman Home Building Group, Inc.,
Indianapolis, IN USA- F.
All Rights Reserved NOTE:
THIS DRAWING IS NOT
All homes have a brick ledge on the front of the home. However, note,
although the brick ledge will be there, it does not represent that brick will be
automatically installed. Cross hatch lines will show brick ledge. Again, note brick
only goes where arrows show brick.
Lot 15
I Elev =907 10
7?
?
X07 313t
SCALE IN -EET
The Green Sheet however will have arrows to show exactly where and if brick is to
be installed. Plot plan dimensions however do show brick ledge dimensions. Pay
close anention to where brick is to be installed. It's the responsibility of all contractors
to note these items and install correctly.
CITY OF CARMEL
Item 1 of 1 PERMIT RECEIPT OPERATOR: vdclan
COPY # : 1
Sec:06 Twp:17 Rng:C3 Sub:CAS Bl.k:l 1,0018
PARCEL ID ........: ZCAS18
DATE =SSUED....... : 01/23/2008
RECEIPT #......... 27251
REFERENCE ID 4 ...: 08010095
SITE ADDRESS .....: 3965 ANDRETTI DR
SUBDIVISION ......: CASE ESTATES
CITY .............. CARMEL
IMPACT AREA ......
OWNER ............. PAUL SHOOPMANN
ADDRESS .......... : 8227 NORTHWEST BLVD
CITE'/STATE/ZIP ...: INDIANAPCLIS, IN 46278
RECEIVED FROM ....: PAUL SHOOPMAN
CONTRACTOR .......: LIC # X.ATKEXC
COMPANY ..........: ATKINS EXCAVATING INC
ADDRESS ..........: 9110 HUGGIN HOLLOW RD
CITE'/STATE/ZIP ...: MARTINSVILLE, -N 46151
TELEPHONE ......... (g12) 422-9467
FEE ID UNIT QUANTITY
- AMOUNT PD-TO -DT THIS REC NEW BAL
----- -------
FLAT RATE 1.00 1396.00 0.00 1396.00 0.00
TCTAL PERMIT ---------- ------
1396.00 ---- ----------
0.00 1396.00 ----------
0.00
METHOD OF PAYMENT
-----------------
CAECK
TCTAL RECEIPT :
AMOUNT NUMB E R
------------ ------------------
1396.CC 2268
1396.00
CITY OF CARMEL / CLAY TOWNSHIP
WATER / SEWER PERMIT / RECEIPT
PARCEL ID #: ZCAS18
LOT & SUBDIVISION: 18 LASS ESTATES
ADDRESS OF CONSTRUCTION: 3965 ANDRETTI DR CARMEL, IN 46032
PAYMENT RECEIVED FROM:
Name: PAUL SHOOPMAN
CHECK #: 2268
EXCAVATOR INFORMATION:
Name: ATKINS EXCAVATING INC
Ph. #: (812) 422-9467 Fax M Email:
Street Address: 9110 HUGGIN HOLLOW RD MARTINSVILLE, IN 46151
Bond Expiration:
PERMIT TYPE: USEWRWATR ; SEWERIWATER PERMIT
Notes/Conditions:
LOT 18 CASS ESTATES. WATER PERMIT
" NO NOTES
Permit #: 08010095
Date: 01/23/2008
The building 8t Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision. or vitrified clav pipe, meeting
ASTM ,pcciFications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with ASTMS 2321 for pve pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall b,
in strict compliance with pertinent City of Carmel ordinances- Back Water check valves shall be installed in accordance with City Code Section
9-122(a)_ and scdions P3008.1 and .2 of the International Residential Code All building sewers shall be 6' diameter.
All installations shall be "oxen french" inspected and approved by the Carmel Sewer Department before any backfiiling is done. Non-
compliance may result in digging up the sewer installation andrbr denial of future sewer permits andlor denial ofwwater connections-
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sewer inspections should be requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OF it E. If any street
tnmt he cut_ a Senar:ite street cut ncrmil shall he OhMined
APPLICANT NAME: RICK GROCE
PAYMENT RECEIVED BY:
FEES:
$1,396.00