Loading...
HomeMy WebLinkAbout08010085 Pool Plans? - -I!- I - PIP s O? Master Pools by TERRY POOL COMPANY INC. 10350 North Michigan Road Carmel, IN 46032 tvfr ???,+? [cIT6 ft.# srAft 380 POOUa L by Ferry Pool Co., Inc. 10350 N. MICHIGAN RD. a CARMEL, IN 46032- (317} 872-2502 a FAX (317) 879-1034 4a if x -5 "p 4 It) I r 3' DG? P Cr n, r T F-4'-) I? I I I Y 'Y T? ) L- ti 1 + r/ i i - i r i f 7 115r AOC 3 '? GENERAE NQTES vn ' . I fnsta!1 a CFI as regt lred 'Dy the h'a;ia-al Electric Code ?,i tti??rr) 1 ,I2•tse,lo } 10S'f' or 1' (25,i n,mi ?+- 470 mm) clnc?u anti the Canadian Electricaa Code. Llghls;iohe Cann. 2. X11 wiring shcJd be done by a (lcenspd electrical con- a iractor in accprdance +rrlth local electrical codes a,^,d as r°`M1d required by the Natfona! Electric Code or t,nt: Can3d7a,r (220 "M) Electrical Code, as applicable. 46 suit s t.aa 3 See Table I for recommended pouf lighting levels. See qnw mRr i Ifa' Dla. Table f,, Page 4, `or lagi 1 niche bulk and cord ipecifica. ? 1?1da. rrin) lions U CLr &! ? U ass wk,h I CAU?I ?.?i A Risk of burns. Lights over 1 CDW nct rec- +4a{wprool;np Nc h•LLi Lc.lic Gampau Iptl; COrt c01?" i ommended for spa. installat on. F. Frsc+ iilnti F+- ? (:.34 MM j Table 1: Typical Lighting Requirements Figure 2: Niche Dimensions l,•^ Allowance of JunE LGr r Wafts/5q, Fool Ccping eoV k Type of poof of Pocl Area - ? Tile Snail ResidenJai Po-Dls W4 Lb(, o . a I Less than aX, sq K (75 sq, 1`71.)1 Jz to 1' •a'ge ?ubhc Pools 1 to 1.1/2 ?o' to .. ua• ED l,ieg Pools (Less,:han (3-E3,y deep) 1,'/2 tD 2 , Divi7s Pools (12 ;o 2G h, (3.65 to 5M,; ceepj d ;0-3 iII• `e 0 7c iursauor * 5cx i24 mo m - - COmpetitiv,n Pools. 2 tc 3" } D T- - , ? ' J Onr SX Wirt light at Detp end 91 pool Is reCpmmended, For conpet ltlon yams: ' I ' .. In t1v.o5 m' I '' c ?r t' ;23.f n, 1 make sure ihnl the starW'flnlsh ends or lanes are well lighted, r d li d l h i d l , o ' b t llpr'?vsc ?,t f c d l' rye ista g , ts n en wa ls ai end :f twirern:ng lanes however, ? O, f short e3urse racing !s provided across the w,ct1 of a 50 meter sS, uont r.ler,. course, €Igh{ fixtu, m.ay t ilstal'ed aetween ,es Nnwe racing II '?fl, s=a 5ta•?#'; is cs R ' ' Imes; on a sgpiriltt switch, bai4-C017.1 ti2 a nml JUNCr•ON 15= + Underwater Llgh[ Locate 1.11n. 0" (1220 mm, 1?eh:nd I ' Approved Pool WLi V4 ]din 1" (2D) mm) ',' l r A• arccrd Clanp Xba',+t? Up of Copin7 ayl .? a, (10, mm) 243 Bars (EM-) Ground From r Power Supply Figure 3; Niche Installation In Cunite Pool any person from contacting it, install :he fixt'_re in cr o r' lain, pool w@,11 with the to of the lens o''g ;ea tt 18 P ",ing at : (203 rrlrn).. _ ,phi') Below the norma, water level of .he pool. Conduit from htofst + J05 and riicl,es shall be ::sad.ln fresh water Powls or tp O r r oplnp + The lens is Feat r2slsta,^,t glass ar,d focuses the ligrs be Elevauar, In a X" horizon-al arc, w'.th 15' downwara defiecticr aria Is seaEed be a rnolced orte-p,'ece wrap-arounc nec Figure Junction. Box, Part ii05 30.Op21 prone gasket. A stainless steel face ring wits I C mcu nl