HomeMy WebLinkAbout08010098 Sewer/Water Permit/sResidential
0077
Permit Type
Subdivision
Section Number
Lift Station
Treatment Plant
Builder
Phone Number
Parcel Acreage
EDU in Gallons
Invoice Number
136
13746
Sunnyvale Ln
Westfield
46074
Hamilton
Local Sewer Charge
Plan Review and Inspection
Application Fee $100.00
EDU Fee $1,650.00
310 Interceptor Fee
Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks- The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH SFP-738 SFP-739 DSMH
Grease Trap No Slab Foundation No Lid Elevation 917.56 ft 916.22 ft
Grit Interceptor No Crawl Space No First Floor Elevation 918.50 ft 918.50 ft
Grinder Station No Basement Yes Basement Elevation 909.50 ft 909.50 ft
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 0,94: 2.28
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met Connection to the sanitary sewer is now permitted.
r0
y ?O
CTRKID
By signing below. I attest that I am familiar with the
Builder / Owner Signature
Printed Name
ifications and agree to accept responsibility for all work done under this permit.
Phone Number
C Z_?'
Permit Date 1/2312008
Revised 112108 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
SANITARY SEWER PERMIT
INDIVIDUAL LOT / EXI STING BUILDINGS
Final Lot Number
Stanford Park Address Number
2A Address 2
23 126th Street Station Street
mix City
Ryland Homes Zip Code
846-2783 County
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test,
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank"... shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR 11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8_ Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site
at http://www.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10/09107
ScMeider
?? XL16 ?96Z_ ?,
The ScLneldVer Cotpaatiou bomaiy o 0 d?
8901 Otis Avenue StzneJine .4 ?+ 'llistddc Fort Harrison landecepe Airddtecdsre'I' A d1
'lndlampok lndlena 48218-IM7 GL4 •I14 2 ?j
917-828-7100 aeolop ?? ?
317-828-7200 Fell( & ?P
Plot Plan Prepared for R.H. of INDIANA
Lot 1 136, containing 6,656 S.F.t, in
Stanford Park - Sec, 2A
Instrument #200600014565
P.C. /4, We /42
q? nay Twp, ?lamttan county
Sec 30, TI 8N, RX
13746 Sunnyvale Lane (50' R/W)
IN 46074
Prepared Oate: 1-17-08 : By: SKN
Proposed Buyiiii Am* and Amino Syed
Comn7un1y Restrictions: Side
Ycrd = 3' MIN.
Rear Yard = 20'
Aggregate = 6' (8.H)
7aning = R2-RESIDENCE-ROSO
R.H. of Indiana
Finished Floor Elevation Information
Pod Grade = 936.3 per plan
Pad Grade + 0.7' = Garage FFE (917.0 )
Garage FFE + 1.5' = Residential FFE (918.5)
Residential FFE - 9.0' - Basement FFE (909.5)
Ground Cover Calculations:
Drive =513 SF=
Public Walk =199 SFt
Private Walk =50 SFt
Hydroseeting =2,593 SFt
Sod =227 SYt , from
Rear of residence.
Optional Sod Package
Hydroseeding =826 SFt
Addl. Soc Pkg.=196 SYt,
Recr easement.
Note: The garage finish
floor elevation is 2.7'
above the curb at the
drive per plan.
M.F.P.C.=914.8
r") v
o
w
n o O1
Cr) It
Z 11 p?
V) S
5Z Z
W
ip
Plot Pl an Legend , >
® Proposed Grades 4 61
000.0 Existing Grades
--000.0-1 Contour Grade
* Approx. Lateral Location
3-
R Sanitary Sewer Lines
Storm Sewer Lines
v Water Service Lines
- - - - Sub-Surface Drain Lines
• Manhole (Sanitary or Storm)
® Beehive Inlet (Storm)
® Curb Inlet (Storm)
D End Section (Storm)
All. Fire Hydrant
Flow Line of swale
Note: Sanl-tory Serer
Top of Costing Information
Upstream Manhole, -C= 917.56
Downstream Mannole, TC= 916.22
per record drawing
Lot # 136
VB08.0084902
Street access ramps tD be
installed in accordance with
municipality requirements.
Sidewalk to be placed
1' from property line,
4' from back of curb
to per plan.
I
L10 20 30
SCALE 1' = 30'
LOT 137
NO E%ISTING RESIDENCE
55.00 =1 1 79.36' {
120.00 75.
' 7.81 j J 916.3
m
1
47.6 m
I 91 6.3
'° rNV
DO `Z B-B
Q 91
y
b 01 N ?
L t
i >o
LuJ
• in
N
U-i
II') I ?j . h t Lr. ??
??
p Q
I ? t h
.
?
Q
?
8C 9? I I LiJ
-)
w
in
$
,
0,
0
i
I
Q
7S 7.9'.
914.8 120.00 916.3 916.0 II I
I Z
LOT 135 I ! z l y) c I
NU EXRjMIN.i IINUtNf t
V? Sen
SIR/739
TCr9I&Z2 00
PER RCD DWG.
1
L.
SIGNATURE t DATE:
SIGNATURE REPfl MIS COWIRMATION OF RECEIPT OF PLOT PUN BY CUSTOMER.
I cwVy that the p or shown hereon was prepared for the benert of the parties ndicted hereon and for the purpose of obtairng o residential construction
permit only. It -s my opinion Oct if the proposed finished groats are cont.ructed as shown, the amfoce drainage on the subject lot will oe eatisfactary for
residential construction. This pion was compiled based on documents prepared by others and The Scnsidr Corporation assumes no liability for ft accuracy,
completeness or occeptance of those documents. This drawing is not intended to be represented as c rehocement or original boundary survey, a route survey,
or a is"yor location report.
FLOOD HAZARD STATDMENT- -he accuracy of any flood hazard data shown on this plot pion Is subject to map scale uncertainty and to any other
uncertainty in location or devotion an the referenced flood insurance rate map (FIRM). ALL of the within described land DOES NOT LE within that special
flood hazard area zone 'AE?, as said land plots by scale on Community Map Rand /18057C 0205F of the flood ihsuronce rate map (nRM) for Hamilton
County, Indiana, Octed Febuory 19, 2003.
UA6WY NOTE
This droving is based oncanetrudian plops orrecord drawings, and is
not based upon a field survey. The Schneider Carparatbn hloes not
warrant the accuracy our sufficiency of this information. Contractors
should verify existing conditions prior to any construction: Any
discrepancy found on this drawing should be immediately reported to
'he Schneider Corporation Falling to do so will result in the
contractor's assumption of all liability.
BASEMENT N07
The basement elevation, depicted hereon, has been determined one
based or the pad grades and/or contours token from the construction
plains for this suD6rsion. Unless stated, no information about
fluctuating water tables, sal conditions, or sod types has been provided
or stated or sc4 plans. this lot is located now a body of water. Lot
or soil conditions rnay require that the basemen; floor elevation be held
two feet (2'4') above normal pod elevation. Site investigation may be
needed if water is encountered during the excavation proanss or N other
krhowr voter elevators or soils condtions are prowl. Inves;Nctlor and
any remedial procedures are at the dlseretion of the buider to
determine and take appropriate steps of action. IF cry ground eater is
encountered during the ncevotion the builder is encouraged to contact
The Schneider Corporation to discuss possible: courses of action
SUMP PUMP NOTE Note. Budder to ensure LATERAL SEPERAION NOTE
Sump pump(s) to be pos live drainage away Controctor to manWn a
plo by builder cs ham structure(s). minimum distance of ter feet
needed (16-01 between water and
CITY OF CARMEL NOTE saNtory laterals.
In the residential districts limiting height to twenty-five
(25) feet, a dwelling may be increased in height to
thirty-five (35), provided the side and rear yords are
increased an additional foot for each foot such structure
exceeds twenty-five (25) in height. (Per Carmel Zoning
Ordinance 26.1.9
_
I OPE
TYPICAL SWALE SECTION
s?
STR/738
Tr,9t7-%
PER RCa DWG.
No.
S0303
STATE OF
?I?
CITY OF CARMEL
Item 1 of 1 PERMIT RECEIPTI OPERATOR: vdolar_
COPY 4 : 1
Sec:20 Twp:18 Rng:3 Sub:STP B1k:2A Lot:136
PARCEL ID ........: ZSTP136
DATE ISSUED.......: 01/23/2008
RECEIPT #.........: 27252
REFERENCE ID # ...: 08010097
SITE ADDRESS 13746 SUNNYVALE LN
SUBDIVISION STANFORD PARK
CITY WESTFIELD
IMPACT AREA ......
OWNER ............ RYLAND HOLES
ADDRESS .......... : 9025 N RIVER ROAD
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46240
RECEIVED FROM ....: RYLAND HOMES
CONTRACTOR .......: LIC # XA-1SUP
COMPANY ..........: A-1 SUPERIOR EXCAVATING
ADDRESS 31143 ROSEWAY DR
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46226
TELEPHONE ........: (317) 898-0767
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC
---------- ------------- ---------- ---------- ---------- ----------
USFWATCONN FLAT RATE 1.00 1396.00 0.00 1396.00
---------- ---------- ----------
TOTAL PERMIT : 1396.00 0.00 1396.00
METHOD OF PAYMENT
-----------------
CHECK{
TOTAL RECEIPT
AMOUNT
------------
1396.00
----^1396.00
NUMBER
------------------
14199
NEW BAL
0.00
0.00
A 1
°""°W CITY OF CARMEL / CLAY` TOWNSHIP
WATER / SEWER PERMIT / RECEIPT
Permit #: 08010097
Date: 01/23/2008
PARCEL ID #: ZSTP136
LOT & SUBDIVISION: 136 STANFORD PARK
ADDRESS OF CONSTRUCTION: 13746 SUNNYVALE LN WESTFIELD, IN 46074
PAYMENT RECEIVED FROM:
Name: RYLAND HOMES
CHECK #: 14199
EXCAVATOR INFORMATION:
Name: A-1 SUPERIOR EXCAVATING
Ph. #: (317) 898-0767 Fax M Email:
Street Address: 31143 ROSEWAY OR INDIANAPOLIS. IN 46226
Bond Expiration:
fhe building b;. Sewer Shall be pvc sewer pipe meeting AST',v1 specifications 3034 SDR 35 of latest revision; or vitrified clay pipe. meeting
ASTN1 specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The ,ewer
shall be installed in accordance with AS rA7 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall bi
in strict compliance with pertinent Cny of Carmel ordinances. Back V+later check valves shall be installed in accordance xith City Code Section
9-122(a), and sections P3008.1 and _2 orthe lntemational Residential Code. All building setiaers shall be 6" diameter.
All installations shall be "open trench" inspected and approved by the Carmel Sewer Department before any backfillink> is done. Non-
compliance may result in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections.
No footing or foundation drains or other sources of ground tauter or storm water shall be permitted to enter the public sewer.
Sewer inspections should be reuuesled at 13171571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sundae or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any strc
mutt he cut. n _aenarrie tilreet cin nermil shall he ahtnined_
APPLICANT NAME: RICK GROCE
PAYMENT RECEIVED BY:
FEES:
$1,396.00
PERMIT TYPE: LISEWRWATR . SEWER/WATER PERMIT