Loading...
HomeMy WebLinkAbout0289.93 MiscellaneousbUIL-NU h' .-(MI I INF-UjHNIAllllN `ARME_-: LAY 0WNSi-iP Department of Community Development CARME= ZONING ORCINANCC 7-160. SEC 70N 29.4.2(3): The Budding Commissioner (Director, Department of Community Development or staff) shall approve or deny the improvement location permit (building pemtlt) within five (5) working days at the receipt of ,he written application form and accompanying matenals. The improvement location permit (building penrnt) shall be issued when the proposed structure, improvement or use and its location conform in ad respe= to this ordinance. 1. ONE completed improvement Location Permit (Building Permit) application. 2. TWO (2) complete sets of construction plans. Building elevations, foundation plan, floor plan and typical wag section must be shown. AA cross-sections must be property detailed and labeled At lease one cross-section must show R-values of building materials to ensure compliance with the Indiana Energy Codes. If minimum R-values are not met on cross-section an Energy Code Compliance Worksheet must be completed. If manufactured trusses are used, a diagram must be included with building plans for all misses being used. Truss diagrams must be stamped with the sea] of the registered architect or engineer who is responsible for that design. Only Indiana registrations will be recognized. If a commercial construction, olars must be stamped aooroved by the Indiana State Deoartment of Fire Prevention & Building Safety. Indicate total height of building on plans 3. ONE copy of sewer permit (from C;ty of Carmel Engineering Dept, Hamilton Western Utilities or Clay Regional Sewer District wnic.lever applies), or septic permit (Hamilton County Health Department). a. ONE (Z) copy of plot plan from subdivision development plan. 5. THREE (3) copies of a site ptan or plot plan showing the following PECUIPED infour an (can be obtained `nom the landowner or developer): -.Name and address of designer of plan with date -Name and address of owrer -Lot number and subdivmcn or applicabte general description -Lot drawn to scale - all dimensions kale and north arrow -Lct/Procerty lines -Minimum from building setback "tne per approved development plan (include all front yard) -,all roads, alleys, rights-of-way, etc. -All other utilities and drainage rights-of-way and easements -Any applicable flood plan area (Elevation Cartificate if necessary) -3u ldirg pad elevation and lot comer elevators -All accessory buildings - existing or proposed -All sidewaks and driveways -Sewer and water lines, septic system (tanks & flied system) and well location -Drainage flow arrows -AU drainage swaies and subsurface facilities (retention/detention areas, etc.) -Sump pump (sump pump pits) showing discharge locations -Geothermal heat pump disc.large locations ALL CONSTRUCTION IS SU&ECTTC REiLD INSPECTION If this Information Is not submitted, it will extend the time it takes to get an approved building permit. I CC.:MFY THAT ALLOF 'HE ASCVE LSTED INFORMATION IS SHOWN COMPi SLY AN0 ACCL'FAi wY CN -HE AFACHED PLOT OR SIT= PLAN AS SUSMI=- Wr7H A BUILDING PERMIT APPL1CATICN TO iriE CARME -CLAY DEPARTMEM7 OF COMMUNITY DEVELOPMENT. I FURTHER CE=r1FY THAT 711-?E JOINING CF WA -,E.21 SUPPLY P1P!NG SHALL BE MADE WITH LZAD-FREE SCLOERS AND FLUXES. FAILURE TO COMPLY WILT. RESULT :N A REPLACEMEINTOF THE SYSTEM. PLUMBING COOE P-509-5. NAME OF PLUMBING STATE PLUMBING LICENSE BUILDER'S BOCA ')or CABO PHONE. ADDRESS: WILL MANUFACTURED TRUSSES BE USED? YES No NOTE: Additional plans and/or information may be required, if submitted plans are not of sufficient c!anty or detail, to indicate the nature and extent of the work proposed and to determine compliaance with all applic acle codes and ordinances. In addition to the above, the Budding Inspector will be provided with any information relative to commitments made in the zoning process for the property in votved. This would include any AOLS and BZA acivity. October. 1992 C.\TE X\1006 dep