HomeMy WebLinkAbout0942.94 Correspondence
Ceco Building Systems
a Robertson Ceoo company
Midwestern Region
P.O. Box 72, Highway 34 and Iris Road
Mi. Pleasant, IA 52641 (319) 365-6001
September 29, 1994
C. R. Jones Group, Inc.
825 Hendricks Dr.
Lebanon, IN 46052
RE; Mr. Robert Irsay
LTs 101-0 x 1411-0 x 111-2
101-0 x 301-0 x 111--2
101-0 x 351-0 x 111-2
RF 801-0 x 301-0 x 131-10
Ceco Work Order No. 64-20110
Live Load: 20 psf
Ground Snow: 20 psf
Wind Speed: 80 mph
Seismic Zone: 1
Collateral Lead: 5 psf
Other: Drifting snow; also heavied for (1) cupola @ 1372#
on Bldg. #1
Code: Indiana w/1981 MBMA wind alt.
C. F JONES GRC)(1R
101-0 x 1111-0 x 111-2
101-0 x 371-5 x 11'-2
RF 1001-0 x 841-0 x 201-0
This is to certify that the referenced structure is designed in
accordance with the order documentation and to withstand the
following loads:
This certification covers the structural design of the framing and
covering parts that are manufactured and shipped by Ceco Building
Systems except accessories such as doors, windows, translucent
panels, louvers, and ventilators, and is exclusive of other parts
of the project such as the foundation, masonry walls, mechanical
equipment, and erection of the building. The building should be
erected in accordance with the referenced job number erection
drawings on a properly designed foundation. If the foundation
designer does not have the building frame reactions by Ceco
Buildings, he should request them from Ceco Building Systems. The
undersigned is not the Engineer of Record for the overall project.
Ceco Building Systems is an AISC certified Manufacturer and has
designed the structural steel in accordance with the applicable
sections of the American Institute of Steel Construction (AISC),
ninth edition, and American Iron and Steel Institute (AISI), 1986
edition. -.? ?' . WIr I
198 SUU,
N 'r-a fG-
Ng?
Z-q 6 -
1. ?T.-b:AL (4
i
Page 2
C. F. Jones Group
September 29, 1994
The metal roof of the referenced building is designed in accordance
with Underwriters Laboratories U.L. Class 90 as listed in
Underwriters Laboratories "Building Materials Directory,"
Construction No. 115. Other materials such as translucent panels
are not included in this certification.
Sincerely,
CECO
??;\J 4AII
L-Richard F. Williamson,
Engineering Manager
Midwest Region