HomeMy WebLinkAbout0191.95 State ReleaseProject number
CORRECTION REQUEST SHEET
State Form 411921n6 ? 8-93) Construction type
•'. Indiana Department of Fire and Building Services
PLAN REVIEW DIVISION
4,32 Wesi Washington Sheet, Room W245 Scope of release requested
i
I Indianapolis, IN 462044
release requested
Receipt number Date
Occupancv classification
A--4
To Owner i Architect! Engineer Preject name
, rte T +'^ t FT 5714ARITY FARMS IND009
3346 AUON kc+H'_ '
Street address
L_ 7:
City Coun
ty
We are holding the above referenced project from further review and release for the reasons indicated below, wherein the plans and ! or spedficaltons fail to
meet requirements of the Departmental rules affecting such building, structure, or system.
1, Qatar closet etalls accessible to the phitsicall'y handi-
capped shall have doors swinging outward from the stall
space in accordance with Rule 4.2, Sections 4.17.3 and
A4.17.5, :HAS (675 IAC 13-4 . 2) .
2. Water closets, accessible to the physically handicapped,
shall have a centerline location of 16 inches from walls or
of '1er obst.ructiony-, in accordance with Section 4 .15.1, Figure
2B, IHA. (675 IAC 13-4.2).
3, The number of plumbing Fixtures inistalled shall be at
least equal to those specified in Table 5-E in accordance
wit)) Section 510(c), 1130 (E75 IAC 13-2?2)
4. Two exits shall be provided from the m!ezzanine in
accordance with Section 1717(5) and Section 3303(x), IBC
(675 IAC 13-2.2).
5, Exit doors shall swing in the direction of exit travel
when serving a-nj hazardous area. or raFran serving are occupant
load of 50 or more, in accordance with Section 3304(b), IBC
(1375 IAC 13-2,2),
6. Corridors shall be constructed of one-hour Fire-resis-
tive construction, with protected openings, in accordance
with Section 3305 kc), and (h), IBC (675 IAC 13-2.2).
F'A'GE ONE OF THREE
Any questions concerning this matter should be addressed to the Code Review Official. RETURN THIS SHEET along with a minimum of 3 sets of the corrected sneets as soon as
possible to the Code Review Official in erder for us to continue processing your plans. If corrected plans and specifications are not received within 34 days of this recuest the
aapppplication w it be subject to denial by the State Building Ccmrriss over m accordance with Section 12,GAR 675 IAC 12-6.12 jbf. IMMEDIATE ATTENTION AND RESPONSE IS
REQUIRED.
Adaress: Name. -title of IoC0 official, street, city, state ZIP code GOde Ravi" official -
Telephone number (call after 1.30p-m.)
one L:?vi C Square
Carmel IN 46032
Distribution: Goldenrod - Architect, Engineer or Owner; Canary - SBC IF Is: Pink - Local Building Official
CORRECTION REQUEST SHEET
.,ate Form 41192 (R6; 8-931
al ndiana Department of Fire and Budding Services
PLAN REVIEW DIVISION
402 West Washington Street. Room W245
Indianapolis, IN 462044
mer i Architect ! Engineer
=' E t"?JkR*i' & ASSOCIATES
H1'Tt'd , RICHARD L BATTERSHELL
3346 AUGN ROAD
AVON IN 46168
I)i121?15'?' 12;5
Construction type Occupancy classification
4
Scope of release requested
Type of release requested
Project name
RID_-WG S-ABLE
i
2000 W 136TH S-T
y County
CARMELrtiLL We are holding the above referenced project from further review and release for the reasons indicaled below, wherein the plans and J or specifications fail to
meet requirements of the Departmental rules affecting such building, structure, or system.
7. FOL- a slab-on-grade floor, the perimeter insulation
shall extend downward from the top of the slab to the bottom
of a tren0: footinc in accordance with Section 502.2.1.4,
IECC (675 IAC
8. The exterior wall assembly shall have a combined thermal
transmittance value III of the gross area of exterior walls
not exceeding the value given in Table 502.3.1, Equation
No. 1 -shall be used to determine the acceptable combinations
in accordance with Section 502.3.1.1, IECC (675 IAC: 19-3-1).
9. The roof/coiling assembly shall have a combined thermal
transmittance value (Uo) for the gross area of the roof not
exceeding the value given in Table 502.3,1, in accordance
with Section 502.3.1.2, IECC (675 IAC 19-3-1).
10. Beginning April 1, 1995, new projects which are re-
quired to be certified by a design professional, in accord-
ance with 675 IAC 12-6-9(a), shall include an affidavit, ex-
ecuted on the form provided by the Plan Review Division, by
each design professional certifying portions of the project,
(NCITARY SEAL: NARAIZE PATEL, AFFIDAVITS: RICHARD BATTER-
SHELL, ALLEN WEIHE)
PAGE TWO OF THREE
Any questions concerning this matter should be addressed to the Code Review Official. RETURN THIS SHEET along with a minimum of 3 sets of the corrected sheets as soon as
possible to the Code Review Official in order for us to continue processing your plans. If corrected plans and specifications are not received within 30 days of this request the
application will be suoject to denial by the State Building Commissioner in accordance with Section 12.GAR 675 IAC 12-6-12 (b). IMMEDIATE ATTENTION AND RESPONSE IS
REOUIRED.
Addre ' Name, title of local official, street, city. state, ZIP code
err, Jones Code Revi ptfic
'r
t
l
t
D
C
eve
Qplrer
ommuni
y
Dept of
One Civic Square Telephone number (call after 1:30 p.m.)
Distribution: Goldenrod - Architect. Engineer or Owner; Canary - SBC File: Pink - Local Building Official
o. CORRECTION REQUEST SHEET
SSate Form 411921 % i S-93?
Indiana Department of Fire and Building Services
402 PLAN REVIEW DIVISION
wrc-
West Washington Street. Room W245
Irdianapolis. IN 462044
To: Owner; Architect! Engineer
"Ir?=r -,SSOCIATES
?'i"Tr, , K ; IitiFL L BATTERSHELL
3346 AVON ROAD
AVON IN 46168
Project number Receipt number Date
]515 I-4 10
II-N
A-4
name
Si'IEFT CHARITY FARMS INDOt)R
ING STABLE t
Street address
i-> I TH ST
city County
H i'1i• 11Fii1T?
We are holding the above referenced project from further review and release for the reasons indicated below, wherein the plans and i or specifications fail to
meet requirements of the Departmental rules affecting such building, structure, or system.
11. Architects or engineers who certify plans shall provide
a signed and sealed page two of the application for their
design and corresponding inspection activities in accordance
with 675 IAC 12-6-6(c)(10). (NARANJI PATEL - SEAL PAGE 2)
12. The owner's certificate shall be signed by the owner of
the installation, building, or bus:nesa, or by the owner's
legally authorized representative, in accordance with 675
IAC 6-6(c)(9). (ROBERT IRSAY)
13, Your project requires a master plan number or structural
drawings in accordance with 675 IAC 12-6-7, 9, and 16.
14. Stair details indicating rise, run, handrails, etc.,
shall be submitted in accordance with 675 IAC 12-6-7(h)(20).
15. A non-adopted standard accepted as set forth in 675 IAC
12-6-11(c). has been used in the review of this pro)ect.
(OVERAREA)
16. The minimum type of construction permitted for this
building is II-FR as determined from Sections 505, 506, and
507, IBC. Building elements shall protected as specified
in Chapters 5, 17, and 19, IBC (675 IAC 13-2.2). (NO
COMBUSTIBLES)
PAGE THREE OF THREE
CST
Any qquest ons concerning this matter should be addressed to the Code Review Official. RETURN THIS SHEET along with a minimum of 3 sets of the corrected sheets as soon as
possible to the Code Review Official in order for us to continue processing your plans. If corrected plans and specilications are not received within 30 days of this request the
GAR 675 IAC 12-6-12 (b). IMMEDIATE ATTENTION AND RESPONSE IS
Commissioner in accordance with Section 12
the State Buildin
lIication will be subject to denial b
a
pppp
g
,
y
ED
E
OUIR
R
Address: jVr?@ Ijtle ?f??cial, street, city, state. ZIP code Code Revrlqh'9'?
ment
Develo
nit
f C
D
t
p
y
. o
ommu
ep 1
i
One C1,.,ic Square :30 p.m.)
Telephone number (ca
l after
1 i'. 4 32
Distribution: Goldenrod - Architect. Engineer or Owner: Canary - SBC File; Pink - Local Building Official
tip, R,.,o Project number -?Receipl nun be,
Release date
CONSTRUCTION DESIGN RELEASE
?I Mate Form 41191 iR6 6-921 Construction type Occupancy classification
Scope of release
Indiana Department of Fire and Building Services 1.
PLAN REVIEW DIVISION
Office of the State Building Commissioner
402 W. Washington St., Room W245 Type of release
Indianapolis, Indiana 46204 H RD
To: Owner., Architect; Engineer Project name
HYDRU F I RE Mir ?1JFF.T CHARITY FARI1?;
ATTN.ROBERT P,
8603 BLUFF R& treet address
INDIANAPOLIS 7 ` n1 7 21100 W 136TH ST
CARMEL I HAMILT01`1
The plans, specifications and application submitted for the above referenced project nave been reviewed for compliance wit'1 the applicable rules of the
Fire Prevention and Building Safety Commission. The project is released for construction subject to. but not recessariiy limited to, the conditions listed
below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work.
All construction work must be in tilt compliance with all applicable state rules. Any changes in Ine released plans and'or specifications must be flied
with and released by this office before any work is altered This release may be suspended or revoked if it s de,.ermined to be issued in error. in vio-
lation of any rules of the state or if it is based on incorrect or insufficient information. This release shall expire by Gm Cation. and become null and void.
if the work authorized is not commenced within one 11;, year from the above date.
Upon completion of this project, contact this department so arrangements can be made for final inspections. This contact may be by letter or statement
of substantial completion.
CONDITIONS:
¢ r. .q -,r .. r ..
F rP _if ;ir,r ,rnFnt. nr r:-t t•rr -. 511 t t t,
Sections 1-3 and 1-8.1.2, t•iFPA 13 tb; I?4C 13-1-31.
2. The complete installation shall comply with NFPA
Standard 13 (675 IAC 13-1-8); Chapter 38, IBC (675 IAC
13-2.2); and all other applicable codes and :standards.
3. The sprinkler installation was reviewed for a Light
Hazard Occupancy. The method of design was "Pipe Schedule"
in accordance with Chapters 2 and 8, NFPA Standard 013 (675
IAC 13-1-8).
4. The location of the fire department connection shall be
approved by the local fire department in accordance with
Section 3801(b), IBC (675 IAC; 13-2.2).
5. An inspector's test connection shall be provided in
accordance with Section 2-9, NFPA Standard 013 (675 IAC
13-1-6).
A set of documents released by this office shall be maintained on the construction site until the structure is occupied (675 IAC 12-6-19).
city. state
Fire
Terry Jones
Dept. of Community Development
One Civic Square
Carmel IN 46032
°"`? CORRECTION REQUEST SHEET
Mate Form 41192 ;R6 ! 8-93)
Inc•ana Department of Fire ane Building Services
PLAN REVIEW DIVISION
sa 402 West Washington Street. Room W245
Indianapolis, IN 462044
Date
To: Owner I Architect : Engineer I Project name
34- 41r?tJ rnAr
Street address
City County
We are holding the above referenced project from further review and release for the reasons indicated below, wherein the plans and r or specifications fail to
meet requirements of the Departmental rules affecting such building, structure. or system.
1. The minimum type of consttr:t:tion permitted for this
hu.ild:ng is I1-N as de-t.errrfined from Sections 505, 5iiki, avid
502, IBC, Building elemerrlta shall be designed as specified
in Chapters 5, 17, and 19, IBC (6?5 IAC 13-2.2). (NON-
COMBUSTIBLE)
2. No change in the character or ube of an•i building or
structure shall be permitted which shall cause the building
or 54-ructura to be classiifed within a fl. Fferent occupancy
group or within a different division of the same occupancy
group, utrlesa such building or structure complies with or is
made to cr_mpl?i with the current rubes, of the Indiana Fire
and Build :ng Sate t.V Cn?nmissiorl, for new cungt rust ion for tl,N
proposed revised use of the building in accordance with
675 IN(: 12-4-11(c). (OURR AREA FOR Ii-N CONSTRUCTION TYPE)
NOTE: OCCUPANCY MUST BE KEPT UNDER 300 TO MAINTAIN DESIRED
A-3 OCCUPANCY CLASSIFICATTON.
3. For a slab-on-grade floor, the perimeter insulation
shall extend downwmrd from the top or tb& 51ab to the bottom
of a trench footing in accordance with Section 502,2.1.4,
LECC 0375 IAC 19-3-1).
Any questions concerning this matter should be addressed to the Code Review Official. R ETURN THIS SHEET along with a minimum of 3 sets of the corrected sheets as soon as
possible to the Code Review Official in order for us to continue processing your plans. It corrected plans and specifications are not received within 30 days of this request the
app cation wii! be subject to denial by the State Building Commissioner in accordance with Section 12 GAR 675 IAC 12-6-12 (bl. IMMEDIATE ATTENTION AND RESPONSE IS
R pQUIRED.
Address: Name, title of local official, street. city, state, ZIP code Code Review official
le pt . r:, f Telephone number (aa# after 1.-30 p.m.)
Distribution: Goldenrod - Architect, Engineer or Owner; Canary - SBC File; Pink - Local Building Official
CORRECTION REQUEST SHEET
State Form 41192 r116/8-93)
Indiana Department of Fire and Building Services
4 i+ PLAN REVIEW DIVISION
"--' 402 West Washington Street. Room W245
Indianapolis, IN 462044
To: Owner! Architecti Engineer
hi:;Hi+k1i L ni-`I lt;lecnLL1.
3346 AVON ROAD
A00N IN 4S l Rig
WI I Tdtaf-IT r.Tslfir
We are holding the above referenced project from further review and release for the reasons indicated below. wherein the plans and i or specifications fail to
meet requirements of the Departmental rules affecting such building, structure, or system.
4. The extarxor wall assembly shall have a combined thermal
trdnsmltt.anCM value (Uri ) of t'nr g-t oss aria of exterior w&1 15
not exceeding the value given in Table 502.3.1. Equation
No. 1 shall be u-,ed to determine the acceptable combinat_10ns
in accordance with Section 502.3.1.1, IECC (675 IAC 19-3-1).
5. 'The roof/ceiling assembly shall have a comb-ined thr.rmaI
transmittance value (Uo) for the gross area of the roof not
exceeding the value given in Table 502.3.1, it accordance
with Section 502.3.1,2, IECC (675 IAC 19-3-1),
PAGE T61") OF TIOU
CJ
Any questions concemmg this matter should be addressed to the Code Review Official. RETURN THIS SHEET along with a minimum of 3 sets of the corrected sheets as soon as
possible to the Code Review Official in order for us to continue processing your plans. If corrected plans and specifications are not received within 30 days of this request the
IMMEDIATE ATTENTION AND RESPONSE IS
12
GAR 675 IAC 12
12
b
i
S
6
;
).
th
ection
.
.
-
application will be subject to denial by the State Building Commissioner in accorcance w
REQUIRED.
Address: Name, title of local official, street, city, state. ZIP code Code Review officia:
t Telephone number (call after 1:30 p.m.)
Distribution: Goldenrod - Architect. Engineer or Owner; Canary - SBC File: Pink - Local Building Official
type
Receipt number Date
Project name
Sj>IEET CHHRIT`t' FARMS INUtit[?
RIDING STABLE
Street address
STATE °f INDIANA
An Equal Opportunity Employer
A Non-Tax Supported Stale Agency
EVAN BAYH
GOVERNOR
INDIANA DEPARTMENT OF
FIRE AND BUILDING SERVICES
Robert Irsay
Sweet Charity Farms
1303 W. 116th Street
Carmel, IN 46032
Dear Mr. Irsay:
OFFICE OF THE.STATE Et 11.111\t: co mmmu WF.R
A'12 N \\yC ^i1a1 Sl,,I. R,.,m E216
In ?i??l..-h Ali. IIx11.ma 1h,'I.13-+?i4
17, +i+.61"
July 7, 1995
This letter provides notice of the action taken by the Fire Prevention
and Building Safety Commission on your application(s) for a variance(s) from
the Commission's rules under IC 22-13-2-11 and 675 IAC 12-5. The Commission
considered the application, as part of its published agenda, at its regular
meeting on July 5, 1995. Information regarding action taken by the
Commission is provided on the attached sheet.
You are advised that if you desire an administrative review of this
action, you must file a written petition for review at the above address
with the Fire Prevention and Building Safety Commission. Your petition must
fully identify the matter for which you seek review no later than eighteen
days from the above-stated date, unless such date is a Saturday, Sunday,
legal holiday under state statute, or day that the Fire and Building
Services Department's offices are closed during the regular business hours;
in which case the deadline would be the first day thereafter that is not a
Saturday, Sunday, legal holiday under state statute, or day that the Fire
and Building Services Department's offices are closed during the regular
business hours. If you do so, your petition for review will be granted and
an administrative proceeding will be conducted by an administrative law
judge appointed by the Fire Prevention and Building Safety Commission. If
you do not file a petition for review, this action will be final.
The purpose of the administrative hearing is to allow you to present
information to the administrative law judge concerning why the decision
should not be upheld. This information can include a re-presentation of
your petition and the reasons already stated, and/or new reasons why the
decision should not be upheld. Please be advised that agency counsel will
be present at such a proceeding, and that you may be represented by counsel
if you wish. Again, if you do not file a petition for review, this action
will be final.
MJC/jt
Attachment(s)
cc: Local Building Official
Local Fire Official
State Fire Marshal
Design Professional
Applicant
File
Sincerely,
Marlys A. Pedtke, Director
Divisions of Technical Services
and Research, and Education and
Information
VARIANCE INFORMATION
FUNCTION:[CJ A=Add D=Delete U=Update R=Clear Screen C-Print Screen
FIND BY: P=Project Number S=Street Name T=City V=Variance Number
Variance Number: [B95-7-7 ] Project Number: [215152 ]
Owner Name:[ROBERT IRSAY ] A/E:[R E CURRY & ASSOCIATES ]
Submitter: [LARRY T HUFF CONSTR CONSULTANT]
Project Name: [SWEET CHARITY FARMS ] County: [HAMILTON ]
City; [CARMEL ]
Address: [2000 ] [W ] [136TH ] CST ]
Other: [ ]
Code/Std Name:[IBC ]Edition:[1993] Sec/Tbl[SECS 505, 506, 507, TBL 17A ]
Subject: [TYPE OF CONSTRUCTION ]
Contact Person for Staff Review: [SUBMITTER ]
Staff Review/Recommendations: [6-15 APPROVE WITH ALTERNATIVES ]
Commission Action: [_] W/D [_] Tabled [_] Approved [.
[AA] Approval Per Applicants Alternatives [?] Approval Per
Date: [070595]
Conditions: [