HomeMy WebLinkAboutPacket 02-19-08 Lighting
I
r
I
:-:-
r.~'..,~ ....
~. ..
~KE
~~et\Q1! 5.6 LiahtinQ ~Elnts.
~~~.
, \.QJ l . ~~.
V'~ \ ~ .'\, A.
.' \
f~. -.-. R:C~~~~ \ \
n, fED (' ~'
\ DOCS,/)
, ~~--~/~j
.... . - ~ ",. ~
,.'"
A site lighting plan shaR be submltted along with the information on
architecturalde$igrl, landscaping, partc;fng. signage. and lighting ("AOLS.
approvalpErtltlon). The site lighting plSln shall includ&the layout, spread and
intensily of all site lighting, jncluding:
t
2.
3.
4.
5.
Parkrng lot and service/storage area lighting;
Arehiteetural display lighting;
Secur1ty Ughting;
Lighting of pedestrian waya; and
land$cap& lighting.
a. All site lighting shag be coordinated fhraughQutthe project and be ofunlform
design, color and materials.
C. The height of IIgntstandards shall not 1)xceed twenty-eight (28) feet from the
top of the fixture to the top of the pole base. The ban of the pote shan not
exceed lwo (~) feet.
D. All exteripr al"ldstreet area lighting fiXtures shall be of the "shoebox~ Ifariaty
whiQh directs tight downward. MY parking lot Ughtfng or building lighting
llIuminat!on emanating from the Parkwood CrosslngWest development shail
not exceed 0, 1 footeandle at the north dght-of..way line of West sa1b Street
and the- east right-of-way line of Sprmg MiU Road.
Section 5. L Slans.
A, OuUot Area Siems.
1.
Number & Type; Three (3) total signs bal!1fJ either one (1) groUl1d
id~ntlflcatlen sign snd ene {1)walJ sign on two (~) building facades
per business; or, ooe (1) well sign on three (3) bullding facades per
business.
2.
Maximum Sign Area:
Ground Sign - 60 sqtIEU'e feet
Watt Sign.. 5% of the facade
Maximum Sign Hsighl:
Ground Sign - S feet
3.
::OJ)t.WMliooMll\N01~.1
16
~
..,-~~'
I~'"
check Software Version 3--:5-:-1
Exterior Lighting Compliance
C e rtifi cate
20061ECC
Report Date: 12128/07
Data filename: X:\2007 MEP DrawingsI240700B5.000_Granite City. Carmel, In\ComCheck\Compliance Report.cck
Section 1: Project Information
Project Tille: Granite City Food & Brewery
Construction Site:
Carmel. IN
Owner/Agent:
Granite City Food & Brewery
5831 Cedar Lake Road
Saint Louis Park. MN 55416
Designer/Contractor:
Larson Engineering. Inc.
14a8 Sond Streel. Suite 100
Naperville. IL 60563
630-357-0540
630-357.0164
Section 2: Exterior Lighting Area/Surface Power Calculation
A
Exterior Area/Surface
B
Quantity
o
Tradable
Wattage
e
Alfowed
Watts
(C II 0)
9120
9120
9120
456
6510
6510
F
Prop Dsed
Watts
C
A.llowed
Watts
I Unit
0.15 Yes
Total Tradable Walts' "
Total Allowed Watts"
TOlal Allowed Supplemental Watts" "
. Wattaga Iradeofls are only allowed between tradable areasJsurfac8s.
.. A supplemental allowance equal 10 5% of lotal allowed wattage may be applied toward compliance of bolh non"lfadable and lfadable
areasfsurfaces.
Parking area(s)
60BGO ft2
Section 3: Exterior Lighting Fixture Schedule
A
Fixture 10 : Description J Lamp J Wattage Per Lamp' Ballast
B C
Lamps! # of
FiKwre Fixtures
o
Fldure
Watt.
E
(e XDj
p~h<l~1jr~~(~}:i@~9;~)i1[~~~~~':i&~~~~~;~~G;,,~:~~P::'!'~\"~l~.'r~:,~'}):...:~g":
HID 1: SFA: Pole Mounted ~bcture I Metal Halide 400W I Electronic
HID 2: SF8: Pole Mounted Fixture I Metal Halide 400W 1 Electronic
HID 3 SFC: Pole Mounted Fixlure I Metal HaHde 400W I Eleclronic
;" ~ ;,' '~! :j;~? ;~~ ~!~}f(~~ : ?~~th~~t;~g:~ ~~;;~~~.t_~ /;'[.~~r ;~~~:~.~: ': ~~~5~;;;:' : .~:~~r:!r:: :'~;~ ~~
,.."... ... ~.;, ~,; d,,," "'-:'"' _ .::'-; ~,:..'i:,1. ' , . ._' ,." ,-" ..,_., ,''''-
8 465 3120
2 465 930
1 4 485 1860
Total Tradable Proposed Watts:. 6510
Section 4: Requirements Checklist
Lighting Wattage:
o 1. Within each non-tradable area/surface. total proposed watts must be less than or equal to total allowed walls. Across all tradable
RrBas/surfaces, total prOlXlsed watts must be less than or equal to total alloweC watts,
Compliance: PassEls.
Controls, Switching, and Wiring:
o 2. All exemplion claims are associated with fixtures that have a control \:Ieviee independent of ltie control of the nonex.empt Iigh6ng.
o 3. AU nonexempt lighting flXluresshall be controlled by a pholosensor or aslronomical time switch that is capable of automatically turning
off the fixture when sifficient daylight is available or the lighting is not require\:l.
Exterior Lighting Efficacy:
Project Tille: Granite City Food & Brewery
Data filename: X;12007 MEP OrawingsI24070085.000_Grani!e City. Carmel. In\ComCheck\O:lmpliance Report.cck
Report date: 12/28/07
Page 1 of 2
i-r~'
:t~
o 4. ,6.11 exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumenlwa"..
Exceptions:
Ga~ t)y motion senSQl'Qr 8x8mpt-~~9YisiQR~GfiQ~,2.
:RA~~ES./G~i1~D;?~A.~be~~ rJTh<l}';lGOd~~ . ~, . e . ",'" ". r. .'. -~- . _'" :
Section 5: Compliance Statement
Compliance Statement: The proposed exterior lighting design representee in this documel11 is consistent with Il1e building plans, specificatior,s
and ather calc:ulations submitted -Nilh Ihis permit application. The proposed Ilghling system has been destgned to meetlhe 2006 IEee
requirements in COMcheck Version 3.5 1 and to comply wilh the mandatory requirements in the Requirements Checklis!.
Nama - Tille
Signature
Dale
PmjeclTilIe: Granite City Food & Brewery
Data filename: X:\2007 ME? Drawings\24070D85.000_Grani~ City - Carmel, In\ComCheck\Complianoo Report,cck
Report dale: 12128/07
Page 2 of 2
~
Percentage of Exterior Material Used:
Stucco 29% 3279 SqFt
Signage 3 ~% 396 SqFt
Stone 22% 2488 SqFt
Brick and Glass 43 ~% 4919 SqFt
Fascia Metal 2% 266 SqFt