Loading...
HomeMy WebLinkAbout06040185 Sewer/Water Permit/sCLAY TOWNSNP REGIONAL WASTE DISTRICT SANITARY SEWER PERMIT [ ] Conditional Permit [ x ] Final Permit INDIVIDUAL LOTSIEXISTING BUILDINGS Project Title: Michigan Road Location: Long Ridge Estates Owner/Builder. Pulte Lot# 31 Street address: 13638 Fossil Dr City: Westfield Zip: 46074 County. Hamilton Interceptor Charges Paid: PRI: EDU Fee:1650.00 Application fee: 100.00 PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during "open trench" phase and before backfilling with sand or stone to six inches above the pipe. NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter the District's sanitary sewer system. The District will assume no liability for drains which are below the arade level of the - - - -« --.......... ..-....J.......1 Le. Tk- permit holder (property owner, developer or builder) will be responsible for damages to the District's sewer systerr This includes damages to manholes, castings, manhole lids and the like; caused by construction activity on the building site which is the subject of this permit. Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 844-9200 24 hours in advance. All new construction will be placed on billing six months after connection has been made or when water is connected, whichever comes first. The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made. I have received a copy of Ordinance No. 9-13-99 and agree to follow all District standards. Building has a [ ] crawl space [ ] slab or [ x ] basement that [ ]will be finished with grinder pump installed to comply with elevation requirements [ ]rough-in plumbing with grinder pump installed during construction, [ x ] rough-in plumbing only and grinder pump will not be installed during construction, [ ] no plumbing in the basement. (Please check appropriate box.) Conditional Permit Terms: [ ] NO CONNECTION to the sewer until further notification. [ ] Certificate of Insurance must be on file with CTRWD listed as certificate holder. [ ] 48 hours notice before work starts on manhole core drilling or cuts of active lines and District inspector must inspect all work before covered. [ ] All District fees will be paid in full. [ ] Approval pending Districts review of plans. [ ] Copies of approved permits from appropriate county or city agencies for work in the right-of-way road cuts or are required. [ ] No occupancy until further notification All Conditions have been met and final permit issued 2006. By signing below, I attest that I am familiar with the District's specifications and agree to accept responsibility for all work done unc si-tM5 permit. 575-2350 Phone Permit issued this 28`h Permit is day of April, 2006. from the date issued. of Administration & Customer sv Permit valid only with CTRWD seal in red ink. ves 2 site plans submitted T'tWo Permit-rev.01-13-06d CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUMMARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may conned to the sewer main per lateral unless otherwise approved by the District. 2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to the District's sanitary sewer. 3. The existing sewer kne from the building to the septic tank may only be used if R is located under a building addition, patio, porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test. 4. The owner or contractor shag notify the District prior to covering the installed lateral so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on site for scheduled inspection, or fails to cancel inspection, an additional fee of 5100.00 will be due. This must be paid prior to the time of the follow up inspection. 5_ Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public sewer, aseptic tank '...shall be abandoned and filled with earthen material in a safe and sanitary manner.' Please contact the appropriate County Board of Health for further information. 6. Acceptable Pipe Materials: PVC PIPE: SDR 35, ASTM D-3034, SIX INCH PIPE PVC PIPE: SDR 21, ASTM D-241, SIX INCH PIPE GASKETS JOINTS ASTM D 3212 GASKETS ASTM FA77 FITTINGS - SDR-26 DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS. CLEAN OUTS TO BE LOCATED THREE FEET WITHIN THE FOUNDATION AND NO MORE THAN 100 FEET APART. 7. Bedding: Use Number 8 crushed stone or Number 8 fractured face aggregate Fill material is to be placed from 6 inches below to 6 inches above the pipe The trench should be a minimum of 18 inches wide 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting SDR 21 and ASTM D- 2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the District and the District's engineer erior to installation. 9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical coupling shall be used. 10. Laterals shall terrnlrate thin 3 feet of the building unless the conditions in Rem #3 above are met. No glued pipe shall be installed outside of building founcat wills 11. Additional information on District standards and specifications maybe obtained from the District's office during business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site at http://www.d?wd.oral, Clay Township Regional Waste District 10701 North College Suite A. Indianapolis, Indiana 46280 Phone: 844-9200 Fax: 8449203 12. Septic effluent shall not be pumped out into the sanitary sewer system. i 13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of inspection 14. Contractors shall lay 14 nauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral. The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top. 15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging. Late ra I-re v. 01-13-06cf "- Gar. FFE = 911.5 STM INLET list Fir FFE = 913.3 TC=909.80 ?N Bsait FEE = 903.5 Gard. Window = 907.5 Drive Slope = 2.1% In n MANCHESTER - ELEV 2C SAN MH 831 TC-910.40 4? Vy\ v RIGHT HAND - Full Brick 'oQ \\ FULL GARDEN BSMT - 9' Walls Sid 3 CAR E 3 J oPoy' `C, - e ntry " Wd Deck 1 u 3 .8' I\ d 5 fl > s t Floo Hazard Note: ?O? >S 31.0' Lot Number 31 Ires within Zone "X per Ure scaled location on the rlood T 5 y Insurance Rate Maps for Hamillon , CFF c County, Indiana (Crnnmundy Panel 1180b7G02051' t d Febr r 19 d 9g q? a? e y , , a ua 2003). Note: V A°R Contractor should verify site specific information depicted hereon with the h? \ ?? 7) ?qN S ?a ?y 7c t' eq f approved construction plans for this ?? ?9S ? g4 F n ASS oFhSTF SG r?" Contractor should Q l Also d t ? T as?R Fc eve opmen . , \ o ° reference Architectural plans for foundation orientation and dimensions. lq ta' \ 1?9. w N t R o e: gti? > ` 06 Minimum Front yard - Vadahle ? pRF Minimum Between Residences - 6' Mimmuni Rear Yard - 20' S ?, F f N 64.5' Not (y9? t The O ? Prot prel ut but b EXIST LAKF #4 '' 9? TS3 the e O, h r N.P. = 900.00 slur 100 YR = 903,17 the Q Ek two 32 sho CITY OF CARMEL Item 1 of 1 PERMIT RECEIPT OPERATOR: twedding COPY # : 1 Sec:19 Twp:18 Rng:03 Sub:LRE Blk:l Lot:31 PARCEL ID ZLRE31 DATE ISSUED.......: 04/28/2006 RECEIPT #•• .... 21935 REFERENCE ID # ... 06040184 SITE ADDRESS .....: 13638 FOSSIL DR SUBDIVISION ......: LONGRIDGE ESTATES CITY ... ......... WESTFIELD IMPACT AREA ....... OWNER ............ ADDRESS ...... CITY/STATE/ZIP .... RECEIVED FROM .... CONTRACTOR ....... COMPANY .......... ADDRESS CITY/STATE/ZIP ... TELEPHONE ........ PULTE HOMES 11590 N MERIDIAN ST, #530 CARMEL, IN 46032 PULTE HOMES LIC # XRTMOOR R.T. MOORE CO., INC. 6340 LAPAS TRL INDIANAPOLIS, IN 46268 (317) 291-1052 FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL ---------- ------------- ---------- ---------- ---------- ---------- ---------- USFWATCONN FLAT RATE 1.00 1310.00 0.00 1310.CC 0.00 ---------- ---------- ---------- ---------- TOTAL PERMIT 1310.00 0.00 1310.00 0.00 METHOD OF PAYMENT AMOUNT NUMBER ----------------- ------------ ------------------ CHECK 1310.00 0050504340 TOTAL RECEIPT 1310.00 ? ;„`,`.p fCITY OF CARMEL / CLAY TOWNSHIP WATER / SEWER PERMIT / RECEIPT 14 ,a Mp PARCEL ID #: ZLRE31 LOT & SUBDIVISION: 31 LONGRIDGE ESTATES ADDRESS OF CONSTRUCTION: 13638 FOSSIL DR WESTFIELD, IN 46074 PAYMENT RECEIVED FROM: Name: PULTE HOMES CHECK #: 0050504340 EXCAVATOR INFORMATION: Name: R.T. MOORE CO., INC. Ph. #: (317) 291-1052 Fax #: Email: Street Address: 6340 LAPAS TRL INDIANAPOLIS, IN 46268 Bond Expiration: Permit #: 06040184 Date: 04/28/2006 The building & Sewer Shall be pvc sewer pipe meeting ASTlt4 specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting ASTIv1 specifications C-7100 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer shall be installed in accordance with AST)1 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section 9-122(a), and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6" diameter. All installations shall be "oven trench" inspected and approved by the Carmel Sewer Department before any backfillins is done. Non- compliance may result in digging up the sewer installation and/or denial of future sewer permits and,lor denial of water connections. No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer. Sewer insMections should be requested at (317) 571-2648 one to four hours in advance. !No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street must he cut. a senarate street cut nermit -hall he obtained. APPLICANT NAME: JANICE STEVANOVIC A PAYMENT RECEIVED BY:? \ FEES: $1,310.00 PERMIT TYPE: USEWRWATR ; SEWERNVATER PERMIT