HomeMy WebLinkAbout08020023 Sewer/Water Permit/sPermit Type
Subdivision
Section Number
Lift Station
Treatment Plant
Builder
Phone Number
Final
Heather Knoll
1
23 126th Street Station
MIX
Mil Homes
317-896-5281
Parcel Acreage
EDU in Gallons 310
Invoice Number
Lot Number
Address Number
Address 2
Street
City
Zip Code
County
19
14357
Heather Knoll Pkwy
Westfield
46074
Local Sewer Charge
Plan Review and Inspection
Application Fee $100.00
EDU Fee $1,650.00
Interceptor Fee
Fees Due $1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below. All installations shall be inspected by District personnel during
"open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation
drains, or other sources of ground or stormwater, shall be pennitted to enter the District's sanitary sewer system. The
District will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for
laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder)
will be responsible for damages to the District's sewer system. This includes damages to manholes, castings,
manhole lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by the District are MANDATORY and shall be arranged by contacting the District's office at 8449200
24 hours in advance. All new construction will be placed on billing two months after connection has been made or
when water is connected, whichever comes first.
The building has: USMH HK-712 HK-711 DSMH
Grease Trap No Slab Foundation No Lid Elevation 918.24 ft 919.76 R
Grit Interceptor No Crawl Space No First Floor Elevation 920.90 ft 920.90 ft
Grinder Station No Basement Yes Basement Elevation 911.90 ft 911.90 ft
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 2.66 1.14
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump
The District reserves the right to inspect all sump pump connections to ensure no illegal connections have been made.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
Conditional Permit Terms:
All conditions have been met. Connection to the sanitary sewer is now permitted.
M??T00
???PHA? MA
c?
C 1 RWD
By signing below, I attest that I am fglniliar with the Dist ict's specifications and agree to accept responsibility for all work done under this permit.
Builder/ Owner Signature
Printed Name
Approved
Phone Number
Permit Date 113112008
Revised 112108 Permit is valid for ONE-YEAR from the date issued. Permit valid only with CTRWD seal in red ink.
Keslaentlal SANITARY SEWER PERMIT
00794 INDIVIDUAL LOT ! EXISTING BUILDINGS
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system within 90 days of notice providing a
sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer lateral installed and connected to
the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it is located under a building
addition, patio. porch or paved driveway. Air test is required to show if acceptable for re-use. The property owner
shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed lateral so that the District can make an
inspection to determine compliance with the District's sewer use ordinance. Such notification shall be made 24 hours
prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on
site for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid
prior to the time of the follow up inspection.
5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of
private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public
sewer, a septic tank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a
safe and sanitary manner." Please contact the appropriate County Board of Health for further information and to notify
the department of the abandonment.
6. Acceptable Pipe Materials
PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE
PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE
RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21,
ASTM D2241, SIX INCH PIPE (use only per approval of the District Engineer)
GASKETED JOINTS: ASTM D3212
GASKETS: ASTM F477
FITTINGS: SDR 26 or better (NO fernco's allowed)
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL:
HDPE DR11 with Compression Fittings, Mechanical or Electrofused Joints
CLEAN OUTS TO BE LOCATED NO MORE THAN THREE FEET FROM THE
FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART.
7. Bedding Use Number 8 crushed stone or Number 8 fractured face aggregate. Number 8 stone backfill material is to
be placed from 6 inches below to 12 inches above the pipe. The trench should be a minimum of 18 inches wide (six
inches on both sides of the pipe)
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting
SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the
District and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed
mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of the building unless the conditions in item #3 above are met. No glued pipe
shall be installed outside three feet of building foundation walls.
11. Additional information on District standards and specifications may be obtained from the District's office during
business hours of 8:00a.m. to 4:30 p_m. Monday through Friday: All District standards can be located on our web site
at http://www.ctrwd.org/.
Clay Township Regional Waste District 10701 College Avenue - Suite A Indianapolis, Indiana 46280
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at 844.9200 24 hours prior to time of
14. Contractors shall lay 14 gauge-solid wire the entire length of the lateral. Wire is to be placed on top of the lateral.
The District inspector will verify placement of the wire. After inspection, bedding is to be placed on top.
15. Call before you dig. IUPPS 1-800-382-5544, 48 hours prior to digging.
Revised 10109107
S!L-
The 9eburlder Corporation
a9m arts k"min
Metairie W Mimi. on
hanspokw Indhne 16 6-1097
St7-12e-7100
317-M-7200 VAX
FLOOD HAZARD STATEMENT
CERTIFICATION
This Plat Plan Prepared For MA Flw=
Lot J 19, containi912,738 S.F.t, in
NODOW K"d
swum 11
P.G ?. Slide 560
Clay TowlOW Hamiton Count
SEC X TIM RU
14357 Heather Knoll Parkway ( 70' R/*)
Westfield, IN 46074
Prepared Dote: 01/28/08 : By. AMH
Cammunily Reslrictiom
Side Yard = 3' min.
Aggregate = 6' B.H.
Zoning - S1
MA HOMES
Pad Grade = 920.2 per plan
Pod Groe + 01 = Goroge FFE (920.4 }
Garage FFE + 0.5' = Residential FFE (92a q
)
Residential FFE - 9.0 Basement FFE (911.9 }
Driveway Slope = 1.65
NOTE: GARAGE F.F.E. IS PROfVSED TD BE
01 ABOVE CURB AT DRIVEWAY T.B.M.
Nolc Sanitary Sewer
Top of Costing Infonrrolion
Upstream Manhole, TC=91@.24
Dornstreonn Manhole. TC=919.76
per record dreg.
Note The contractor is to rnailtrin a
minimum distance of ten feet (To')
between the sanitary sever and hater
line kiterab.
GROUND COVER CALCULATIONS:
Drive = 974 SFt
Public Walk =1,158 SF+
Private Walk =N/A SFt
Seeding = 7,026 SF+
Sod = 476 SYt,
from front of residence.
Nate; Budder to
ensure positive
drainage away
from structure(s).
Note:
This drawing is based an construction plans or record drolmgs,
LWAO P kftdatem and is not based upon a field survey. The Schneider Corporation
Go -in does not worront the accuracy or sufficiency of this information.
"Wee Contractors should verify existing conditions prior to any
construction- Any discrepancy found an this drawing should be
reported to The Schneider Corporation immedwtelf, failing to do
so results in the contractors assumption of oil licbiity.
Plat Plan Legend Note
the bas rrieni devotion, depicted hereon, has been delernrrled
Proposed (fades and bared m the pod grodes and/err rontaun alien from the
000.0 Existing Grodes sanstruetim tdmo for This subdivision. WOM stated no
r OOD.Q? Contour Grade infarmtkn doul Wuoting Bola tables, d om$limm or Sall
* Approx. Lateral Location typo hos ban provided err stated m avid Ova We lot Is
Sanitary Sewer Lines booked new o bade of water. Lot or d cardtk m may row*e
sir Storm Sewer Lines Uot the tom, I kor devotion be laid 2 foot above nwind
v Water Service Lines Pool elevolion. Ste knedigollon may be needed if Voter is
- - - - - - - Sub-Surfoce Drain Liles encountered during ere own+dim process or if othar 6von
e1 Manhole (Sanitary or Storm) scow elewtirr err waits oondfttars OR PrNnt. hvveeTTgatlan a4
Beetlive Inlet (Siorm) any rww" procedure Is at the dhairtlon of The bukw to
Curb Inlet (Storm) detemrine and Tape appropriate steps of action. K my ground
p
D End Section (Storm} voter is maunterd during excavation the buidr is ancorsoged
Ak. Fire Hydrant to contest The schroadir corporofian to am" posstde ca a
s
of octim.
- -0 e - a e a - Flory Lyle of swde
Building Lire (BL / BSL) NOTE
- - Ft _- - - Easement Line SUMP PUMP(S) To BE PLACED
4T2 BY EKJK ER AS NEEDED.
STR.
rrt ga. ?
95.00'
15' D.E.
I.r]' d
30.0'
Q-11
W
J
Z
W
t?
U
51.5'
WMERICK A
F MddM
RE510Et1CE ow
Co
0
Sri
M
TWEE CAR
GARAGE
9
`??????,?? t 11 t 116 t 1 I I I I I I J I! 1! r l r I r r r?ii??
M
S03?3
STATE OF
ff?? rtityt Aµ?•.?Q?y? 1?? ?,
?9 711
r,?rrlml?niltntn',tu???? RECORD
I OR WG
This drawing is not int ded to a represented as a retracement or
original boundary survey; 0 r0Ule survey, or a Surveyor Locotion Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown an
this Oct pion is subject to map scale uncertainly and to any other
uncertainty in location or elevation on the referenced flood insurance rote
map (FRNI. ALL of the within described land DOES NOT UE within that
special flood hazard zme W, as said lard plots by scale on Community
Wop Panel / 1BM10DOIC of the flood Insurance rate maps (FIRM) for
Hamilton County, Indians, Dated May 19, 1981.
a: 20.33' tour n?,m -LU 25' B.L. - - '?
ZO' D.U.&E. MW_
DQK
'
74.90 ;ao
5` tlAllf I
I PS -
14.6 5 p f
B-0 PER RM EILEY=919.7
HEATHER KNOLL
LOT# 19 Z
_
4-1 ° COPE
SL
?
pp? 4.1
TYPICAL SWALE SECTION
NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING
HEIGHT TO TWENTY-FIVE (25) FEET, A DUIELLINIG
-Arm- MAY HE INCREASED IN HEIGHT TO THIRTY-FIVE (35)
FEET PROVIDED THE SIDE AND REAR YARDS ARE
Q INCREASED AN ADDITIONAL FOOT FOR EACH FOOT
Assumed North SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET
Scale - 1" = 30' IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1.
CITY OF CARMEL
Item 1 of 1 PERMIT RECEIPT OPERATOR: t
COPY 4 : 1
Sec:20 Twp:18 Rng:03 Sub:HEK Blk:l Lot:19
PARCEL ID ........: ZHEK19
DATE ISSUE.D....... : 02/05/2008
RECEIPT #......... : 27329
REFERENCE ID # ...: 08020021
SITE ADDRESS .....: 14357 HEATHER KNOLL PKWY
SUBDIVISION ......: HEATHER DOLL
CITY ............. : WESTFIELD
IMPACT AREA ......
OWNER ............. M/I
ADDRESS ........: 8500 KEYSTONE CROSSING
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46240
RECEIVED FROM
CONTRACTOR ...
COMPANY ......
ADDRESS ..
CITY/STATE/ZIP
TELEPHONE ....
M/I HOMES OF INDIANA
LIC # XA-1SUP
A-1 SUPERIOR EXCAVATING
31143 ROSEWAY DR
INDIANAPOLIS, IN 46226
(317) 898-0767
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
---------- ------------- ---------- ---------- ---------- ---------- ----------
USFWATCONti- FLAT RATE 1.00 1310.00 0.00 1310.00 0.00
UWATERTAP FLAT RATE 1.00 86.00 0.00 86.00 0.00
TOTAL PERMIT : 1396.00 0.00 1396.00 0.00
METHOD OF PAYMENT AMOUNT NUMBER
----------------- ------------ ------------------
CHECK 1396.00 14976
TOTAL RECEIPT 1396.00
CITY OF ICARMEL / CLAY TOWNSHIP Permit #: 0802002'
WATER / SEWER PERMIT / RECEIPT Date: 02/05/2008
'h:iP V4
PARCEL ID #: ZHEK19
LOT 8i SUBDIVISION: 19 HEATHER KNOLL
ADDRESS OF CONSTRUCTION: 14357 HEATHER KNOLL PKWY WESTFIELD, IN 46074
PAYMENT RECEIVED FROM:
Name: Mil' HOMES OF INDIANA
CHECK #: 14976
EXCAVATOR INFORMATION:
Name: A-1 SUPERIOR EXCAVATING
Ph. #: (317) 898-0767 Fax #: Email:
Street Address: 31143 ROSEWAY DR INDIANAPOLIS, IN 46226
Bond Expiration:
The building & Sewer Shall be pvc sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision, or vitrified clay pipe, meeting
ASTM specifications C 70t1 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The sewer
shall be installed in accordance with .ASTN€ 2321 for pvc pipe and the Uniform Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City of Carmel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6" diameter.
All installations shall be "oven trench" inspected and approved by the Carmel Sewer Department before any backfillina is done. Non-
compliance may result in digging up the sewer installation and/or denial of future sewer permits and+or denial of water connections.
No footing or foundation drains or other sources of ground water or storm water shall be permitted to enter the public sewer.
Sewer inspections should be requested at (317) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 14 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. If any street
mu;l he cut a senamir street cut nermit shall he obtained.
APPLICANT NAME' R L GROCE
PAYMENT RECEIVED BY
FEES:
$1,396.00
PERMIT TYPE: USEWRWATR ; SEWERIWATER PERMIT