HomeMy WebLinkAboutA200D (TYP.) 8'-6" AFF PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS NOTED OTHERWISE. REMOVE EXISTING SWITCHES THAT ARE NOT RE-USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. CEILING HEIGHT THROUGHOUT THE SPACE IS , UNLESS NOTED OTHERWISE. EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING TILES AND CEILING GRID THAT IS BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN CEILING TILE, UNLESS NOTED OTHERWISE. COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE BUILDING STANDARD, UNLESS NOTED OTHERWISE. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. REFER TO DESIGN-BUILD DOCUMENTS FOR INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT SIGNAGE, LIFE SAFETY SYSTEMS, 24 HOUR EMERGENCY LIGHTING, VENTILATION, HVAC SYSTEMS, CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC. THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE IN COLOR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR. A GENERAL REFLECTED CEILING PLAN NOTES B C D E F G H I J K L M N O DENOTES NEW 2' X 2' ACOUSTICAL CEILING GRID/TILE (BUILDING STANDARD) DENOTES DRYWALL CEILING 2' X 4' LIGHTING FIXTURE (BUILDING STANDARD) 2' X 2' LIGHTING FIXTURE (BUILDING STANDARD) 4" DIAMETER CANLIGHT (BUILDING STANDARD) WALLWASHER (BUILDING STANDARD) SWITCH SWITCH ON DIMMER PENDANT FIXTURE - SPECIFICATION TO BE DETERMINED BY DESIGNER EXIT SIGN EMERGENCY LIGHT REFLECTED CEILING LEGEND NOT IN CONTRACT A2005 REFLECTED CEILING PLAN REFLECTED CEILING PLAN D ALL EXISTING CONDITIONS AND REQUIRED LOCATIONS MECHANICAL CONTRACTOR SHALL FIELD VERIFY GRILLES AS INDICATED ON DRAWING. RELOCATE NEW DIFFUSERS AND RETURN AIR ALL MECH EQUIPMENT AND DUCTS ARE EXISTING MECHANICAL NOTE