THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE
CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION.
ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS
AS INDICATED ON DRAWINGS OR AS REQUESTED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH
DESIGNER PRIOR TO INSTALLATION.
ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATA
LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR)
TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED.
ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE.
ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FOR
MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY.
ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" A.F.F. TO CENTERLINE OF
OUTLET, UNLESS OTHERWISE NOTED.
SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING STANDARD
COLOR.
ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS
OTHERWISE NOTED.
DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE
SOUND TRANSMISSION.
ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL
BE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS.
CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCAL
BUILDING CODES.
ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES,
BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY.
DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD
CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST
BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS
BY ATTACHING RECEPTACLES TO NEAREST STUD.
THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEER
FOR FURTHER TECHNICAL INFORMATION.
ELECTRICAL/DATA OUTLET LOCATIONS TO BE VERIFIED WITH TENANT PRIOR TO ROUGH-IN. ALL
LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT.
A
GENERAL ELECTRICAL/DATA NOTES
B
C
D
E
F
G
H
I
J
K
L
M
N
O
ELECTRICAL/DATA LEGEND
GENERAL ELECTRICAL/DATA NOTES
COORDINATE EXACT ELECTRICAL/DATA SPECIFICATIONS FOR THIS AREA WITH TENANT.
PROVIDE ELECTRICAL FOR GARBAGE DISPOSAL.
DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE
DENOTES GROUND FAULT INTERRUPTER
+##
GFI
DEDICATED QUAD RECEPTACLE
DEDICATED DUPLEX RECEPTACLE
110V STANDARD QUAD RECEPTACLE
110V STANDARD DUPLEX RECEPTACLE
VOICE/DATA OUTLET
NOT IN CONTRACT
A3006
ELECTRICAL/DATA PLAN
ELECTRICAL/DATA PLAN