HomeMy WebLinkAboutA300C5 48144TBL C5 C5 C5 C5 C5 C2 C2 C2 COPIER C5 364DLF 364DLF 364DLF C5 364DLF 364DLF 364DLF C2 C2 C5 2072DPCRED C2 C2 3672DPDESK C5 2072DPCRED C2 C2 3672DPDESK C5 2072DPCRED C2 C2 3672DPDESK C5 2072DPCRED C2 C2 3672DPDESK C5 2072FSCRED 2072DPCRED C5 3672DPDESK C2 C2 C1 C1 42DIA C1 C1 C2 C2 3672DPDESK C5 2072DPCRED C1 C1 42DIA C1 C1 C2 C2 3672DPDESK C5 2072DPCRED +42 GFI +60 GFI +42 +42 +42 +42 +42 +42 +42 +42 +42 GFI THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS AS INDICATED ON DRAWINGS OR AS REQUESTED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED. ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FOR MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" A.F.F. TO CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING STANDARD COLOR. ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS OTHERWISE NOTED. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE SOUND TRANSMISSION. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL BE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES, BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY. DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHING RECEPTACLES TO NEAREST STUD. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEER FOR FURTHER TECHNICAL INFORMATION. ELECTRICAL/DATA OUTLET LOCATIONS TO BE VERIFIED WITH TENANT PRIOR TO ROUGH-IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT. A GENERAL ELECTRICAL/DATA NOTES B C D E F G H I J K L M N O ELECTRICAL/DATA LEGEND GENERAL ELECTRICAL/DATA NOTES COORDINATE EXACT ELECTRICAL/DATA SPECIFICATIONS FOR THIS AREA WITH TENANT. PROVIDE ELECTRICAL FOR GARBAGE DISPOSAL. DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE DENOTES GROUND FAULT INTERRUPTER +## GFI DEDICATED QUAD RECEPTACLE DEDICATED DUPLEX RECEPTACLE 110V STANDARD QUAD RECEPTACLE 110V STANDARD DUPLEX RECEPTACLE VOICE/DATA OUTLET NOT IN CONTRACT A3006 ELECTRICAL/DATA PLAN ELECTRICAL/DATA PLAN