HomeMy WebLinkAboutLighting Booklet
Table of Contents
Relativity 2-3
Optical DesignNersatility 4-5
Mechanical Design 6-7
Installation and Maintenance 8
Arm Mount
Ordering Information
Post Top Mount
Ordering Information
Proportion Guide
Photometries: See separate
CC/CCS Photometric Catalog,
10-11
12-13
15
~ KIM UGttTNl
SITE I AREA
PARKING STRUCTURE
ROADWAY
ARCHITECTURAL FLOOD
ACCENT
LANDSCAPE
MAILING ADDRESS:
P.O. BOX 60080
CITY OF INDUSTRY, CA
91716-0080
BUSINESS ADDRESS:
16555 EAST GALE AVENUE
CITY OF INDUSTRY, CA 91745
U.S.A
PHONE 626 I 968 - 5666
FAX 626 I 369-2695
ENTIRE CONTENTS
@COPYRIGHT2000 KIM LIGHTING INC.
ALL RIGHTS RESERVED
REPRODUCTION IN WHOLE OR IN PAAT
WITHOUT PERMISSION IS STRICTLY PROHIBITED.
PATENTS PENDING
www.kimlighting.com
......,..
~ ~
~ 11
. .
., ~
~ . ~
., . ., ..
~
AvA Council
lor Accreditation
Audited to ISO 9001 Standards
Printed in U.SA
5501600122
Version 5/00
CC/CCS
Curvilinear Cutoff Series
-.~ ~,
. I
...
The CC/CCS Series:
These performance luminaires
are conceived as a total
integration of design and
technology, Kim's third generation
of Curvilinear Cutoff luminaires
represents the most current
technology in specification-grade
outdoor lighting.
This family of cutoff luminaires is a
direct response to the needs of
today, engineered with tOmorrON'S
insight. The CCICCS product line
is designed \0 surpass tough
demands, such as energy
efficiency, glare control, light
trespass, aesthetic and structural
integrity, all manufactured to Kim's
standards for quality, longevity and
performance.
., ......
f=-
-1l1li \:j~.
. ~ ...,.
Iii ~
Q~~I
.
,. I
(011
I
---
I
~,-
~- -
--
_:... ~
~
--
-
]
~
. I
/ ,,.:.,,....
.--
-
--
....
.!
~4
~ . >
Kim Theory of Relativity
Integration of Luminaire Design and Architectural Site
CCA Curvilinear Cutoff Arm CCP Curvilinear Cutoff Post LTV LighlvaulfA
VRB Vandal Resistant Bollard
AFl Architectural Roodlight WF Wall Farm'
/('1.
''''''0
l". ~,
f1),'J.:>' "If.. . ^
41Te 0;, ~l:.
Sign A~O'"
<l11(j riA1..q
Sc<lle If "'C~ .
elt'ili~ PITO"
Slop, ""00
Osilion. rJ ""0",
""thin S.
Its Are .
"h"eel
lIre
KIM THEORY OF RELATIVITY
AI Kim, product is developed In conte>:t, as It relates to Detail.
Performance and Proportion. Oetan to connect fixture
appearance to the site and archrtoctural clements. Performance
to provid" high visibilil)i while using energy e<<",iently. Proportion
to reflect the proximity to structures as well as site occupants, As
illustrated below. each zone leading to a structure presents a
unique set of criteria. The Slle I Roadway Zone roquires large
scale sources, rrJOunted high and spaced widely. to provide
uniiorm illumination. Pedestrian Zone luminaires are more visible,
mounted lower and provide higher illumination levels 10 draw
CCP
21'or25'
,...
,...
,...
,...
,
SW Site Wallfarm
we Wall Director'"
attention and enhance security, The landscape I Path Zone
requires fixtures closest to occupants, delineating paths and
connecting the site with the structure Itself. The Building I
Perimeter Zone requires design intimate with physical
architectural elements while proViding texture and highlight.
draWing attention Lo entries, and producing a sense of secunly.
lighting practice is a blend of aesthetic design, perfonnance and
effect. Integraling Ouldoor Lighting Wlth Sit. Archllectur. is the
Kim Theory of ReloUvlty.
~
i ':'#&,
01 10
D QU
o
SITE I ROADWAY ZONE
The CC Curvilinear Cutoff Seres on 20' - SO' poles, provides large sit" and roadway
areas the IlIum.,ance and uniformity required for safety and securil)i. Efficient cul-<lff
oplics Improve Visibility and reduce light trespass. The optional Accent Reveals feature
9Jslomizes the fi>:ture to conn""t with the architectural dotailing
PEDESTRIAN ZONE
The CC CuNilnear Ctldl Series on 10' - a:r pJies
providas peOOsttm arW3 rcrm>Jd V1Slb1ty ood
acca1l The II3d.ced fixlue scale ald cpiJCn3J
Accent Reveals feature mailtains contif'lJity.
LANDSCAPE I PATH ZONE
VRB I'ardaI P<Js<sIar( Bdmts ooi'mle paIto, delre
lraffi:: panems <nl esIabIsh a 9EJ'\OO d wetxm; inl
secuty lTV li;t\Ml~, h.graOO In:ls:ape i111i1Q
pt>.'i:Es Iij1I g"i wItIu.I ""-"I d:lsln.d0l.
BUILDING I PERIMETER ZONE
AFL Architectural Floodlights provide highlight in archilec1urally sensitiva enclosures
WD Wall Directors<!ll provide an up or down light function while maintaining aesthetiC
continuny. SW Site Wall forms highlight entries and facades v.I1ile enhancing archlectural
style WF Wall Fcrms" provide unobtrusive stair and perimeter walk illumination.
KI" LIGHTING
Optical Design I Versatility
Sharp Cutoff, Visual Uniformity, Maximum Pole Spacing
Anyone of these criteria is demanding. To achieve all three in a
single luminaire requires Kim's expertise. The ee optical system
utilizes a horizontal lamp orientation to achieve sharp cutoff and a
flat lens configuration for minimum visual brightness. The primary
reflector panels are highly specular to achieve precise
distribution and cutoff. A careful redirection of the uplight spreads
light downward to properly fill the mid-ranges, while excessive
straight down illumination is avoided by the elimination of
downward reflecting surfaces.
A. High-angle maximum candlepower and sharp cutoff are
produced by the smooth specular side panels.
B. A specular peened upper reflector spreads light into the
mid-range, gradually increasing the intensity toward higher
angles while avoiding any low-angle reflections.
C. At low angles, bare lamp illumination is adequate,
eliminating the need for downward reflecting surfaces to
optimize uniformity.
~~
A. Typical horizontal lamp luminaires produce excessive straight-
down illumination in relation to the side throw. This causes poor
uniformity.
B. The ee's reflectors have reduced straight-down illumination with
increased side throw. This produces excellent pole spacing and
uniformity.
Rotatable Optics
All ee reflectors are field rotatable in 900 increments. This allows
design flexibility in producing very high illumination levels for
special applications, or maintaining a constant fixture geometry in
relation to surrounding architecture.
~@4~
Types II, III or IV reflectors can
be rotated into a parallel
orientation with a standard dual
mounting configuration. This
provides very high illumination
levels often required for
tennis courts and automobile
dealerships.
Design Flexibility
If a constant fixture alignment is desired, single or dual mounts can
remain in the same orientation while rotating reflectors to change
light patterns.
For single post top mounts, the fixture yokes can be installed in
alignment throughout the site with reflectors rotated to optimize
light distribution.
[:g
C!JE]
+
%
+
4 KIM LIGHTING
Four Light Distributions
The CC series offers a selection of light
distributions to tailor the lighting system to
site geometry. The following distributions
are available:
Type II: Typically used as a single fixture
for narrow roadways or alleys, and as a
dual mount for site entrances,
Available in 17: 21"and 25",
Type III: Typically used as a single fixture
for roadways, pathways or site
perimeters, and as a dual or quad mount
for site lighting. Excellent for wall
mounting.
Available in 17~ 21~ 25' and 29~
Type IV: Typically used as a single fixture
for site perimeter or wall mounted,
Excellent results with houseside shield
option,
Available in 17: 21: and 25',
Type V Square: Typically used as a
single, dual or quad mounting for general
open site lighting.
Available in 17~ 21~ 25' and 29'.
Where light trespass must be controlled
on adjacent property, houseside shielding
is available on Types II, III, or IV
asymmetric distributions.
Seven Mounting COnfi;n~ + ~
Seven mounting configurations
are available using one to four
fixtures per pole, plus single wall
mounting.
--
--l
,"" :..-:=-: - -.' ~
-- - .-
<;::-,~
-
8
G G 0
/,
I.E.S, Type III I.E.S. Type IV I.E.S. Type V
Forward Throw Square
I.E.S, Type II
Superior Visual Uniformity
While maintaining sharp cutoff and wide
pole spacings, the CC produces excellent
visual uniformity. For pole-mounted area
and roadway luminaires, optimum visual
uniformity is achieved when the maximum-
to-minimum footcandle (Fc) ratio is held
below 12:1.
I 8 3.45 1.17 3.45 g
4.00 2.50 1.10 2.50 4.00
120' 2.22 1.45 1.00 1.45 2.22
1 4.00 2.50 1.10 2.50 4.00
8 3.45 1.17 3.45 g
170'
Test No.: ITL 39429
Fixture No:
2B/CC25A3/400HPS
Mounting Height: 30'
Maintained Average: 2.7 Fe
Maintained Maximum: 11.3
Maintained Minimum: 1.0
Maximum/Minimum: 11.3
KIM LIGHTING I>
Mechanical Design
Strength Coupled with
Architectural Character
Engineering and design were
conceived as one discipline in
the CC series. The goal was to
produce a housing with very
high strength, low weight and
aerodynamic drag, simple
geometry, and basic architectural
compatibility. The logical solution
was a clean cylinder accented
by horizontal reveals.
Our precision computer-controlled
spinning process is used to
produce the clean, crisp
housing with consistent wall
thickness and smooth sides.
Three reveals are rolled into the
housing for stiffening and to
create a smart, classic profile.
The final process adds a
support flange by mechanical
hemming, eliminating welds
and fasteners.
,
,t
t...
\
t..
\ .
~
......
--
:;;.-
:r'~
~.
....
~r~:--':
I'
d _
"F:
f[::
~~
High Strength Yoke
Post top mounted CCs utilize
Kim's unique yoke configuration
which optimizes component
strength while reducing stress
on the welds. The key element
of this design is a single tube
system which spans the lens
frame with longitudinal welding
at the hub. This design
efficiently transfers the fixture
weight to the center hub and
away from the welds. Stress at
the weld is minimized to resist
wind and vibration forces. The
base hub serves as a splice
compartment and completes
the horizontal-plane design
developed in the housing.
Heavy cast
aluminum lens frame
\-;1-----
..-
--- ---
360' welding of support arm on
inside surface of lens frame
. /
_J p~->
---- . ~
I
--
Cast Aluminum splice
compartment cover
--1-
~~
One-piece heavy
tubular aluminum arms
Cast Aluminum base
and splice compartment
Longitudinal
arm welds
U KIM LIGHTING
..,
Durable Powder
Coat Finish
Kim's state-of-the-art powder
coat paint system is
engineered to provide the
highest quality finish with
absolute paint adhesion under
weather extremes. The Super
TGIC thermoset polyester
powder coat finish is applied
over a chromate pretreatment,
This finish system has
exceeded the A.S.T.M. 1000
hour salt spray test, enduring
over 5000 hours without failure.
ALUMINUM
Eight Stage Finish
1. Power wash and degrease.
2. Detergent tank bath.
3. Clear water rinse bath.
4. Chromate bath. The best
known pretreatment of
aluminum for corrosion
resistance and paint
adhesion.
5. Clear water rinse bath.
6. Dry off oven.
7. Powder coating, 2.5 mil
nominal thickness.
8. Bake for 20 minutes at
410oF.
CHROMATE
- PCWIIDER COAT
Low E.P.A. Housing and Components
The choice between round or square housings becomes a "no
contest" selection when the effect of wind is compared. A round
housing produces 40% less E.PA (Effective Projected Area) than
a square housing having the same width and heigh\. This
translates to a large potential savings, as lighter gauge poles may
be utilized.
Square Luminaire
===-1P~ '\
-)
~~J.
SJ
""......
Coefficient of Drag (CD)
I
25'
--L
1.2
Round Luminaire
25'
L
0.7
EPA
1.5
2.5
Comparison of 25' round and square arm mounted luminaires
shows 40% less E.PA for the round unit. The same percentage
decrease also applies to post top mounted fixtures.
Sealed Optics
In outdoor lighting it is not
enough to seal the optical
chamber from outside air,
moisture and insects. Some of
these contaminants can also
enter through internal
wi reways , which is why all CC
optics are totally sealed inside
and out. This assures
maximum performance
between maintenance cycles
which are typically three to five
years.
\,..~
--'fl.'
~
Self-Retained
Screw
Housing
Flat Tempered
Glass Lens
Cast Aluminum
Lens Frame
Silicone Lens Gasket
KIM LIGHTING S
l'nstallation and Maintenance
Maintenance and Access
Fast installation and easy maintenance are achieved by modular
construction. Hinged lens frames (arm mounts) and housings (post
top mounts) lock in the open position freeing both hands for work.
Reflectors snap out for easy access to the housing interior. The
ballast module is factory prewired with quick-disconnect plugs, and
mounts inside the housing with keyhole slots. Pole mounting uses
the least number of fasteners, maintaining simple, clean detailing.
Post Top Installation
Post top mounts can be
specified with Kim's patented
wedge grip. A single concealed
bolt attaches the fixture.
Prewlred ballast module
Arm Mount Installation
Arm mounts utilize a draw-bolt
system concealed within the
arm's internal centering guides.
ll_
~--
,
J
III
B KIM LIGHTING
:;--= ~ .-.-
I~" ~;:::- --::
.1- - -1 ~..,..,.., ....
=-..S -- .~. . . 1
......."",." ~
-~ ~-
.1-1 f J. ...~ ....1
,.,.,.- r;.,., ~
- ~
...,jloi-
~
r'. ;
I
.... ~
~....~
...
..
~
....-
";\.~~,..,:\~ ': * I"
. ,;'"~_~~..:1;~~..'t..-:.. If'
--
.' ~k~~'f"< ~-
- .....-.:;;...; ........
...... _ "'::.J. - ~.....--
-----~ -~~ - ...--
~ .~ ~--
-- ~.-- ---. ..~ -- :;..~
-- ~ ~~ - --- ~ ~
... _...--~~
~
---'
l' _......-&
~ --"~ ...
---.- - - - -- "":.:.- ,
:...-----r - ----- --l
....--;-- . ~- ---:
~~ __ . _~.i
~ ____ I
1.-- ~ -- --
.. -:~ ...-o:.~
r:-:::r _ .. 1 ~ ~~ --::;::;
.., __ __ .J ~ .....~. ~
-- - ,---
_ .-J-- --
.. ~
...
.. .......
- - -
r-~ ~ ~-
..... :..;.. ,.,. .......
-:. --~-
","""~
-~...~
.,.
-...
---
--
~
~_...
...
....,
...-
...
---
-.,-
..~
-,,;
-~
;:;:-
.-
.. ....
...~
.....,. IJ~
_ _---... r ~ -,' ..,.. \
__-- _ .-._ _ '--r
~_I_ _ --- ----- .....,r-.""'--'"
..J.--- _......_.....-.~
.................-~
r.....-r .
. I ~ ~ ]
.......;.jj
................ -.-
...; ....,J:o.-.o. ~
---
---- ....-.--.
..
--- ........---
...----
Ordering Information
Curvilinear Arm Mount
17"S~l~~~~
70 to 1000 Walt II
Ordering Example:
For Standard Fixture
and Pole
l.tutr,g FO:.tUHl E)Q;trlCalYodu!e FnI$l1 OctOO$ AccoMlQ8"I.ealS,--- P:-\It' -----,
1A I CC25A3/400MH277/ LG-P/ A-33 / BL-REV / PRA30~250A / LG.P
1 2 3 4 5-11 12 13
For CC onfy. ~ ~at.; Kim ~ CetaI~.
Qrritfcy1WWaIPA:xrt.
4 Finish:
Super TGIC powder ooa, paint
fNff ctrarate <:coJSrSi:f1 coa!i'Q
'- ... e;: + ~Wall
Mounl
2L 3T 3Y 4C 1W
1.6 2.5 25 2.6
2.2 34 3.4 39
2.7 4.3 43 49
33 5.2 5.2 59
r or seleCtiOn of ftXlLJ'e and moLIlting conftQlr"atiofl based (Y1
pIlOtornetnc performance, see ~Ie CClCCS PI1olomolric Catalog
/, ' ,
,-..... ,. ,
Ughr DiS1ributiofl' TWell TIP" III T ypa IV TI'IJOV
Forwa/aThrc'H s"",.
Cat. No.: CC17 AZ CC17A3 CC17A4 CC17A5
CCS17AZ CCS17A3 CCS17A4 CCS17A5
light Distribution Typo II TIP" III Type IV Twe V
r.llw.dnll,.'W 3~",
Cat. No CC21 A2 CC2IA] CC21 A4 CC2 I A5
CCS2 lAZ CCS21A3 CCS21A4 CCS21A5
L ighl Distribution: Type II Twelll Type IV Type V
'y Fo-w....c111"w0000 ~re
Cat No.: CC25A2 (CC:a.~3) CC25A4 CC25A5
CCS25A2 CCS25A3 CCS25A4 CCS25A5
5 Optional Photocell:
Factory ins.ta.lled photocell in
housirlg with tully UCIfi"'l:ltBd
serIS()l"OOsidewaJLFor 17.,21",
and 25' fixtures only
Mounting:
3Y confIguration is available
for round poles only.
Plan View . ..
Cat No' 1A 28
EPA 17': 0.9 lB
21': ,.2 2.4
25': 1.5 30
29': 1.8 36
Fl:o:ture
.. Fixture with phOtocel
. 51"", uni~s)
2 Fixture:
Cat. No, designates CC/CCS
fixture and light distribution.
CC fixtures tla\l€ 3 horizontal
reveals.
CCS fiXlUres have 1 horizontal
groove.
See the K!m Site/Roadway
Optical Systems Catalog lor
detailod irlforrn<l.tion on reflector
des~n and applicatk>n.
CC
ccs
9
Color: Block Dart< Bronze light Gray
Cat No.: BL-P D8-P LG-P
'Consult representative for OJSlom COIOfS.
'Custcrn Colors
CC-P
~
17'
CC
CCS
P1i1tinum Silver
White
WH-P
~
9l
PS-P
Mourdillg (st:!f't pagA 1 D)
21'
.;~
~j9
./
CCS
CC
... .~~a
lA.tW :>H
~, 'I~l
2L 3r,3Y
wat1age per fixture VoltagB
1:>0
70-400W 200
240
7O-250W 400
1:20 2A.30
20B 2A-31
400W 240 lA,32
277 2A-33
347 lA-35
48() 2A-34
rfE
~',
.I~,. 4C
r'
I~. 4C
6 Optional Photocell F Cal. No.: A.25 Factory installed in flat portion of housing top for NEMA base
Receptacle: pho1ocells by others Cat. No. A-25 applies tm all voltagt'ts
29" fixture only. (1211V-4HOV).
One per ti:dura required.
7 Optional Convex Glass ~ Cal. No.: CGL TemperEd convex glass lens f4Jplaces stand<:trd tlat lens
Lens:
8 Optional Polycarbonate ~~~,~ C", "".: PotycartKJnale RhiAlrt rep..mas slandard tempered glass lens.
Shield: L17 for 17' nodels 250 watt ma:dmum, May be used with 4~PS in OIJtdoor
U1 fer 21' models k:>cations were ambient air temperature during fi>cture operation
US kr 25' rrojels will not exceed 8~"F.
9 Optional Houseslde
Shield:
CJ:f'-::
CC29A:l
CCS29A:l
CC29A5
CCS29A5
2'>'
Type III
Type V
....."
1 0 Optional Vertical
SlipflUer Mounts:
3 Electrical Module: CCiCCS 17' CClCCS 21' and 25' CCICCS 29'
HI'S . HIgh Pressure Sodium 70H1'S120 100HPS120 150HPS120 150HPS120 2SOHPS120 4OOHPSI20 750HPSI20 1000HPSl20
70HPS208 100HPS2C8 150HPS208 150HPS20B 2SOHPS208 4OOHPS208 750HPS208 lOOOHPS2C8
MH . M""'I~KJe 70HPS240 l00HPS240 150HPS2411 150HPS2411 2SOHPS2411 4OOHPS240 750HI'S24O 1000HPS240
70HPS277 100HPS277 150HPS277 150H~77 250H~77 400HPSID 750HPS277 lOOOHPSm
PMH _ PU!:E Slalt 70HPS3o\7 100HPS3o\7 150HPS347 150HPS347 250HPS347 4OOHPS3o\7 750H1'S3o\7 lOOOHPS3o\7
Metal HalH:le 150HPS480 25OHPS480 4OOHPS480 750HPS480 101lOHPS480
70MH120 looMH120 150MH120 175MH120 25OUH120 4OOMH120 1000MH120
~ 70MH208 10010111208 150MH20B 175MH208 25OUH208 411CMH208 1000MH208
70MH240 1ooMH2411 150MH2411 175MH2411 25OMH2411 411CMH2411 1000MH240
70MH277 100MH277 150MH277 175MH277 25OMH277 4OOMH277 ll1OOMH277
70MH347 100MH347 I5OMH347 175MH347 25OMH347 4OOMH347 1 1IOOM1l347
175MH480 25OMH480 411CMH480 100OMH4BO
Lamp lamp Line 175MH120 250PMH120 4OOPMHI20
Wans Type Volts 175MH20B 2SOPMH208 411CPMH208
175MH2411 25Of'MH240 4OOPMH240
400 HPS 277 175MH277 250PMH277 400PMHID
175MH347 4OOPMH3o\7
4OOPMH4eO
KIM UGHTlNG
11 Optional Horizontal
Sllpfltter Mount:
12 Optional Accent
Reveals:
For CC <Hies OIly
13 Poles:
Cat. No.: HS
for 11'. 21', and 25" models with Types II, III, or IV distributions
only. HeoommendEld for use with clear la:TIps only.
Fffeclivp.n~*, ifl rodllClld fCH coaled lamps.
Cat. No.: HSC
For lixluftf:i witll optional COfW€X glass lens or JJQlycarbonate
shield. Nut for use with T~'J}e V light diSltibtJtioos
~D
II "' Sl~fi"€, noond
Cat. No
VSf.1A
VSF.2B
VSF-2L
VSF-3T
VSF-3Y
VSF-4C
Allows Sl<:Indard fil(luftl arid arm
to be IT\CtJnred 10 polos having a
2' pipe-size tenon (2Ys" 0.0.)( 4'h"
minimum length).
Mounting Configuration
1 A - Single arm mount
28-2a11600
.2:L-2al904
3T - :3 at 9lr>
3Y . 3 at 120=
4C - 4 at 9ll"
~
Cat. No: HSF
Replaces standard mounting arm with a slipfiUer for mourlling
to a horizontal pde dOlvi\-<wrl ..v;th 2' pipp.~sile mOlJoting end
(2%'00)
rpg
coc.r!'lad< [8k Ekme Lkt1t Gray PIatir1.rn SMI ''''h'e 'Cu;bn la",
Cat No' BL./lEV ~ LG-REV PS-.'IE\I WK-REV CC~
I CCoSlAt rep-esernati've fer ClJStC('l colors.
See Kim Pole Cata~ for a complele selection of round and sqLJare poles in aluminum or steal.
KI M L..IGHTlN(i
Ordering Information
Curvilinear Post Top Mount
CC/CCS
17' - 29' Post Top Mount
70 to 1000 Watt
T
Ordering Example:
FCll Standard FIXture
a'1d Pc;e
Mc.ur.iv Fl':tufe ElKllicaJ U;:dJ1e r .,1Sl'1 Opfbn~ ~~l F\twelll'l. I Pr>>:e I
FM / CC25P5/400MH2771 LG-P / A.J3/ BL-REV {PRAJ0-6250FM / LG-P
1 2 3 4 5-9 10 11
4 Finish:
Super TG1C fX)wder coal pain!
lJ'.6 dIDml:e cn1VEr'OOl 00:lbrg.
For CCorw".
Mounting:
EPA. 17' 21" 25' 29'
0.7 10 1.2 1.5
~~
\~."J
PT Post Tenon Mount
2" Pipe-9ro To-un (2%" 0.0. )( 4~' L)
2" PIpe-size TetUl (2W 0 D. )( 4W L)
2' f1pe-size Teooo (2l\' 0 D x 414' l)
2' f1pe-size Teooo (2l\' 0.0. x 414' l)
~
Cat No
Pole Top
Requirements
17' 30/.t. 4', 4W 5' Dia
21' 4: 41>". S', or 6"[]a
25' 4: 4W. ~.., a: 6'DIS.
29" 4: 4W. S', or tn)ia
2 Fixture:
Gal. No. designates CC/CCS
fixture and ti~t distribution.
~ 'WP$fstEl Kim PQ.e- Cataog
~
5 Optional Photocell:
Fac1OI'y installed photocell in
housing with fully gasketed
SflfE(I OIl 008 wall. For 1 r, 21'.
and 25" fixtures (Xlly_
DM Direct Mounl
r<a
31"loa9' lJia.
3.1"1039' Dia
31'1039' Dia
6 Opllonal Photocell
Receptacle:
29' fi_e onty.
FiKl:urB
For selection of fixn.e <ifill frvUlti'1g conligt,mtm based on
pha1afTlclric perkxlJ1anoo, see the CClCCS Photometric Catalog.
7 Optional Convex Glass
Lens:
3 Electrical Module: CCiCCS 17' CCICCS 21" and 25' CClCCS 29'
HPS ... Hgh Pressure Soc:Iium 7OHPS120 1DOHPS120 150HPS120 150HPS120 250HPS120 .woHPS120 75OHPS120 1DOOHP5120
70HPS208 I DOHPS208 150HPS208 150HPS208 250HPS208 _5208 75OHP5208 1000HPS208
MH ' Metal Halide 70HPS2oIO 1 DOHPS2AO 150HPSUO 150HPS240 250HPS240 _S240 75OHPS240 1UDOHP5240
PMH = PUse Start 7UHPS277 1 DOHPSm 150HPS277 150HPS277 250HPS277 _5277 75OHP5277 1000HP5277
70HPS347 lDOHPS:W7 150HPS347 150HPS347 250HPS:W7 _5347 75UHPS347 1000HPS347
Metal Halide 150HPSo4aO 250HPSo4aO 4OOHPS480 750HPS480 1000HPS48U
70MH120 1DOMH120 150Mli120 175MH120 250MH120 4OOMH120 1DOUMH120
~ 70MH208 1 DOMH208 150MH208 175MH20B 2!iOMH208 4OOMH208 1DOUMH2U8
7OMH240 1 DOMH240 150MH240 175MH240 2!iOMH240_ lDOUMH201O
70MH277 100MH277 150MH277 175MH277 2!iOMH277 M~ 77 1UIlUMH277
70MH347 lUOMH347 150MH347 17~MH347 2!iOMH347 4OOMH:W 10DOMH347
175MH4BO 25OMH4BO 4UOMH4llO 1000MH480
Lamp lamp line 175MH120 250PMH120 4OCPMHl20
Watts Type IIolts 175MH208 250PMH208 4OOPMH208
175MH240 250PMH201O 4OOPMH201O
400 HPS Xl7 175MH277 250PMH217 4OOPMH217
175MH347 4UOPMH347
4OOPMH480
........ /-
ee CCS light Di~1ributiof1' TYflt-:! 11 lype lit
~ T
Cal No: ee17P2 ee17P3
17' eCS17P2 eeS17P3
CC fixtures have 3 horizontal
reveal9
ee ees Light Di~iribuliotl Type It lype III
~ 9
Cat. r-.k:l.: CC21 P2 eC21P3
21' CCS21P2 ee521P3
CCS fhdures have 1 tto.ilOlltal IH ees Light Distribution Type II Type III
groove. ~. err
~' Cat 1\\).. CC25P2 ee25P3
See the Kim Site/Roadway CCS25P2 eeS25P3
Optical Systems Catalog for
delaJled information 011 reflector ec ee5 ligh1 Distribution: Type III
design and applicatKxl. I 9
Cat. No: CC29P 3
29" CeS29P3
" ' -
, ,
Type IV Type V
.euwardThlI."lY S,"",",I(O
CC17P4 eC17P5
eeS17P4 CeS17P5
Type IV Type V
Fof.,.~dnro", SQ\,UIrlr
CC21P4 ee21P5
CCS21 P4 eCS21PS
TwelV
~~Ttvt.\III
CC2~P4 \
CCS25P4
Typo V
s......
eC29P5
eCS29P~
8
Optional Polycarbonate
Shield:
9 Optional Houseside
Shield:
10 Optionel Accent
Reveals:
FrI a.; !Hies oiy-
11 Poles:
KIM L.IGI-lTlNG
/'
Color: Black Dark Bronze (ugh Gray
Cat No.: BL-P OB-P LC-P
'Coosu~ f1lI)feSeI1tabve tar cusIom -.-s
9
lirlHVoItS
Cat No..
/ R&:Ep~c'e Cat N:).: A.25
~
~ ~,~
Co<w.. G1.., l&<1S
Cat No:
~ L17 for 17' rrodeIs
L21 for 21' rrodeIs
L25 for 25" mxteIs
PCilycarbon.a'~ Shie-ld
~ Cat.No HS
urr'\- HS 101 ''''' I." "I
_ Cal No' H5C
~ HSCb...""" lensD!
.. poIYCArbMR.te shldd
Platinum Silver
PS-P
Whih:l
'r.:l~torn C'..nklrs
WH-P
ee-p
(9
347V
...-3~
120V
A-:W
208V
....31
240V
...-32
4BOV
A-34
Factory installed ill rlousing lOp lor NEMA base
ptKJtocel!9 bV other9 Cat No_ A.2! applirn:; for all voltClgBS
( 120V-4BOV).
eGL
Tempered cOl1\lex: glass lens replaces standard Mat lens,
Pdycarbor~o Stj~d u...'PIaces. ~1<mdard lelnpt100 gldss lens
250 v..att maximLm May be UStX:l v.ith 4OOI-lPS irl UlAd:x:r IocatblS
were ambief1t air temperalUfe d.nng fixn.re operation v.;tl not
6"ceed 85~F.
For 17',21", and 25' rrodels....i1h Types 11,111, or IV disUiblltioos
only. Recomrnen<led tar use with clear lamps only. EMecliveness
is reduced tor coaled lamps.
For fiKtures with optional conV8)1 glass lens Of polycarbonate
shield. Not for use wi1h Type V lighl distributions.
lr: Color: _k Dark E!ro1ze lightG-ay. Aallrun"""" V_ 'OJstamQ::bs
Cat No.: OB-REV LG-REV P5-I<EV WH-REV ~
" 'COnsuIt fe abve for custom COlors.
Rti...wI8~
See Kim Pole Catalog Jar a oomplele selection of round and square poles in alumil1lJm or slool
..
. -.
.. -
"I.
)
;;.
.~~
... .
~ ~ -..:
.... -.
"'" .....
-l:.~' ,
. L
-
h
Proportion Guide
70 to 1000 Watt / 1 A' to 50' Poles
48'
46'
50'
29. DIA. Models: 750 to 1000 Watt
35' to 50' poles
44'
This proportion diagram is inlended to help visualize and
select the best CC system to satisfy aesthetic requirements.
Remember, the pole height also affects performance; the
higher the fixture is mounted, the greater the light throw. If
poles are mounted on concrete pedestals such as in parking
lots, the height of the pedestal must be considered in
selecting the pole height.
42'
40'
38'
36'
34'
32'
25. DIA. Models: 150 to 400 Watt
25' to 35' poles
30'
28'
26'
24'
22'
21. DIA. Models: 150 to 400 Watt
20' to 30' poles
18'
5"
6" x 10n
Tapered
Poles
20'
16'
14'
17' CIA. Models:
70 to 175 Watt
10' to 20' poles
12'
10'
8'
4"
5"
5"
40
6'
4'
2'
GRADE
KIM LIGHTING 11 5