HomeMy WebLinkAboutSign Description_Stamped Approved
PENN ON PARKWAY WALL SIGN CRITERIA
PURPOSE:
GENERAL:
The purpose of these sign requirements is to assure sign continuity and
uniformity throughout the office complex. It is always essential that the
signage compliment the Architectural design of the area and that the
esthetics of the complex be maintained.
All signs must be approved, in writing, by Landlord or its representative.
All signs must consist of illuminated channel letters cross section with LEDS
flush mounted to the building. All letter components are to be constructed
and installed as described within the following criteria.
Tenant shall be responsible for the fulfillment of all requirements and
specifications, including those of the applicable local governing agency
and/or codes, and obtaining all necessary sign permits.
Tenant shall be responsible for the installation and maintenance of their sign.
Should Tenant's sign require maintenance or repair, Landlord shall give
Tenant thirty {30) days written notice to effect said maintenance or repair.
Should Tenant fail to do same; Landlord shall have the right to undertake
repairs and Tenant shall reimburse Landlord.
Wording of the sign shall not include the trade name of products sold or the
price of items sold except as a part of the Occupant's trade name or
insignia. Use of generic terms will be reviewed on an individual basis.
DESIGN: Tenant signs shall not be restricted to a certain letter style or font. Each letter
or logo construction, lighting, and installation must be consistent with the
letter components of the National Electrical Code. Layouts must be
submitted to the Landlord for written approval prior to sign construction.
Drawings must include copy, size, colors, placement and a cross section
detailing the installation. Upon approval, a permit application must be files,
by tenant, with the Carmel/Clay Township Department of Community
Development. A copy of the approved permit must be returned to the
Landlord prior to sign installation.
No sign of any sort shall be permitted on top of the building roof.
All exterior signs exposed to the weather shall be flush mounted.
3/18/2025
CONSTRUCTION:
LIGHTING:
Letter and logo components are to be constructed from 5" depth
.040" Aluminum Returns, painted black. The faces are to be
fabricated from 3/16" acrylic faces with black perforated vinyl
overlay with a 1" black trim cap.
Illumination is to be white LED's.
BUILDINGS: 301 Pennsylvania Avenue
There may be a combined total of four (4) wall signs for the building.
The north and south facades may have a maximum of two (2) signs.
401 Pennsylvania Avenue
There may be a combined total of four (4) wall signs for the building.
The north and south facades may have a maximum of two (2) signs
501 Pennsylvania Avenue
There may be a combined total of six (6) wall signs for the building.
The maximum number of signs per facade shall be not more than
two (2) signs.
SIZE:
PLACEMENT:
INSTALLATION
No letter can be taller than 54" in height. Sign lettering may be on
two lines, but shall not exceed a total height of 54" .
Final placement will be determined by the Landlord. Signs must be
centered horizontally with adjacent signage on the building. A
photo rendering of placement must accompany the spec drawing
for final approval. The Landlord reserves the right to adjust
placement to ensure architectural compatibility with the facade.
All components are to be installed flush mount. All lighting to be
manufactured to be UL Codes. All secondary wiring is to be
installed on the backside of the wall enclosed in grounded metallic
flexible conduit. Transformers are to be installed in metal boxes on
the backside of the wall. Primary wiring to the sign shall be
separately metered and is the responsibility of the tenant. The
tenant is to maintain a consistent on/off schedule as specified by
the Landlord or City Code requirement. All signs are to be
fabricated and installed based on LL. specifications. All Illuminated
signs to include a disconnect switch.
All conductors, transformers, and other equipment shall be
concealed. Electrical service to the sign shall be on Tenants meter
and shall be part of Tenant's construction and operation costs.
All bolts, fastenings, clips, railway, etc., shall be painted to match
the building fascia.
No sign maker's label or other identification will be permitted on the
exposed surface of sign except for those required by local
ordinance, in which case it shall be placed in an inconspicuous
location.
3/18/2025
All penetrations of the building structure required for sign installation shall be
neatly sealed in a watertight condition.
Sign contractor shall repair any damage caused by their work. Damage to
structure that is not repaired by the sign contractor shall become the Tenant's
responsibility to correct.
Tenant shall be fully responsible for the operation of the Tenant's sign
contractor and shall indemnify, defend and hold the parties harmless from
damage or liabilities on account thereof.
NOTE: The Landlord shall be notified a minimum of 48 hours in advance prior
to the sign being installed on the building.
INSTALLATION WORK MUST BE PERFORMED AFTER WORKING HOURSE OR
WEEKENDS.
REMOVAL
GUARANTEE
Upon lease termination, the Tenant is responsible for the removal of the
sign and repair to the wall from the installation and use of the sign to the
condition of the wall prior to the Tenant's installation of the sign.
The Sign Company shall carry workman's compensation and public liability
insurance against all damage suffered or done to and all persons and/or
property while engaged in the construction or erection of signs in the
amount of up to $2,000,000.00 and $1,000,000.00 per occurrence.
Landlord reserves the right to hire an independent electrical engineer (at
Tenant's sole expense) to inspect the installation of Tenant sign and to
require the Tenant to have any discrepancies and/or code violations
corrected at the Tenant's expense.