Loading...
HomeMy WebLinkAboutConstruction & Landscape Plans7260 SHADELAND STATION INDIANAPOLIS, IN 46256-3957 TEL 317.547.5580 FAX 317.543.0270 www.structurepoint.com 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 APP R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C002 GENERAL NOTES GENERAL NOTES DEMOLITION NOTES SITE NOTES GRADING NOTES UTILITY NOTES EROSION CONTROL NOTES GR A N D B O U L E V A R D FAIRFAX MANOR DRIVE (FUTURE BY OTHERS) ALLEY (FUTURE BY OTHERS) AL L E Y ( F U T U R E B Y O T H E R S ) ST R E E T A ST R E E T A (F U T U R E B Y O T H E R S ) G R A N D B O U L E V A R D ( F U T U R E B Y O T H E R S ) (FUTURE BY OTHERS) 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C101 EXISTING TOPOGRAPHY/ DEMOLITION PLAN GR A N D B O U L E V A R D FAIRFAX MANOR DRIVE (FUTURE BY OTHERS) ALLEY (FUTURE BY OTHERS) AL L E Y ( F U T U R E B Y O T H E R S ) ST R E E T A ST R E E T A (F U T U R E B Y O T H E R S ) G R A N D B O U L E V A R D ( F U T U R E B Y O T H E R S ) (FUTURE BY OTHERS) 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C201 SITE PLAN GR A N D B O U L E V A R D FAIRFAX MANOR DRIVE (FUTURE BY OTHERS) ALLEY (FUTURE BY OTHERS) AL L E Y ( F U T U R E B Y O T H E R S ) ST R E E T A ST R E E T A (F U T U R E B Y O T H E R S ) G R A N D B O U L E V A R D ( F U T U R E B Y O T H E R S ) (FUTURE BY OTHERS) 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C301 GRADING PLAN GR A N D B O U L E V A R D FAIRFAX MANOR DRIVE (FUTURE BY OTHERS) ALLEY (FUTURE BY OTHERS) AL L E Y ( F U T U R E B Y O T H E R S ) ST R E E T A ST R E E T A (F U T U R E B Y O T H E R S ) G R A N D B O U L E V A R D ( F U T U R E B Y O T H E R S ) (FUTURE BY OTHERS) 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C401 UTILITY PLAN GR A N D B O U L E V A R D FAIRFAX MANOR DRIVE (FUTURE BY OTHERS) ALLEY (FUTURE BY OTHERS) AL L E Y ( F U T U R E B Y O T H E R S ) ST R E E T A ST R E E T A (F U T U R E B Y O T H E R S ) G R A N D B O U L E V A R D ( F U T U R E B Y O T H E R S ) (FUTURE BY OTHERS) 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C501 EROSION CONTROL PLAN 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 x x x x x x x x x x x C510 STORM WATER POLLUTION PREVENTION PLAN x x x x x x x x x x x x x x x x x x x x 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NOT F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C520 EROSION CONTROL DETAILS x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NOT F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C521 EROSION CONTROL DETAILS x x x x x x x x x x x 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NOT F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C522 EROSION CONTROL DETAILS 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C800 SITE DETAILS 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C801 SITE DETAILS BIKE RACK DETAIL 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NOT F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C810 CITY OF CARMEL SANITARY SPECIFICATIONS 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 AP P R O V A L P E N D I N G NOT F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 C820 CITY OF CARMEL SPECIFICATIONS F.F.E:869.00 PROPOSED HOTEL BUILDING 14,180 S.F. T 0.2 0.3 0.3 0.6 0.7 0.6 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.6 0.7 0.6 0.4 0.4 0.5 0.5 0.4 0.3 0.2 0.1 0.8 1.4 3.0 5.8 7.1 4.8 2.3 1.2 0.8 0.7 0.8 1.0 1.5 3.1 5.7 7.0 4.8 2.4 1.3 1.1 0.9 0.6 0.4 0.2 0.1 1.0 2.0 4.2 7.0 8.4 6.5 3.1 1.7 1.0 0.9 1.0 1.3 2.3 4.3 7.0 8.4 6.4 3.3 2.1 1.7 1.3 0.9 0.5 0.2 0.1 1.0 1.6 2.9 4.7 5.2 4.3 2.5 1.5 1.1 1.0 1.1 1.4 2.0 3.1 4.7 5.1 4.3 3.1 2.6 2.4 1.9 1.1 0.5 0.3 0.2 0.5 1.0 1.5 1.7 1.5 1.3 1.3 1.6 2.4 3.4 3.8 3.2 2.2 1.5 1.2 1.1 1.3 1.7 2.1 2.6 3.4 3.8 3.7 3.4 3.5 3.3 2.5 1.3 0.7 0.4 0.2 0.6 1.2 2.2 2.7 2.4 2.0 1.8 1.9 2.4 3.1 4.0 3.3 2.5 1.9 1.6 1.6 1.9 2.7 3.1 2.9 3.1 3.4 3.7 4.2 4.6 4.2 3.0 2.1 1.3 0.7 0.2 1.0 3.7 3.0 2.5 2.4 2.9 3.9 5.6 4.3 3.1 2.3 2.0 2.2 2.9 4.6 4.9 3.8 3.5 3.6 4.1 4.6 5.2 5.7 4.4 3.9 2.3 0.3 4.6 3.7 3.0 2.9 3.5 5.2 8.5 5.9 3.9 2.8 2.4 2.9 4.4 7.7 7.8 5.0 3.8 3.6 3.8 4.1 4.7 6.8 9.4 5.7 0.8 0.3 7.1 5.9 4.4 3.6 3.1 2.9 3.3 4.8 8.0 5.4 3.5 2.5 2.2 2.5 3.5 5.8 5.9 3.8 3.1 3.0 3.4 3.8 4.5 6.8 9.5 5.7 10.0 6.1 3.8 3.3 2.8 2.5 2.5 2.9 4.5 3.2 2.2 1.7 1.5 1.7 2.2 3.3 3.3 2.4 2.1 2.2 2.9 3.8 4.8 5.6 4.5 4.0 2.0 4.6 5.7 5.4 4.1 3.3 2.6 2.0 1.7 1.8 2.4 1.8 1.4 1.2 1.1 1.2 1.4 1.8 1.8 1.4 1.3 1.6 2.2 3.2 4.2 4.3 3.3 2.4 1.5 0.9 1.7 2.6 3.0 4.3 4.1 3.1 2.1 1.5 1.2 1.1 1.3 1.1 0.9 0.8 0.8 0.8 0.9 1.1 1.0 0.9 0.9 1.1 1.5 2.2 3.2 3.7 3.3 2.0 1.2 0.9 0.9 1.5 2.6 3.2 3.1 2.2 1.5 1.0 0.8 0.8 0.9 0.8 0.7 0.6 0.6 0.6 0.7 0.8 0.7 0.6 0.6 0.7 1.0 1.5 2.3 3.1 3.2 2.5 1.5 1.4 0.5 2.0 2.3 1.9 1.4 0.9 0.6 0.5 0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.5 0.7 1.1 1.8 2.7 3.4 3.3 2.4 2.7 1.3 1.4 1.1 0.8 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.5 0.8 3.5 3.9 3.4 4.6 0.2 0.2 0.2 0.2 0.2 0.2 3.4 4.1 3.6 5.0 3.2 3.4 2.8 3.5 2.8 2.7 2.0 2.1 2.6 2.4 1.7 1.8 2.9 2.9 2.2 2.7 3.1 3.5 3.1 4.4 3.1 3.8 3.4 4.8 2.7 3.0 2.5 3.5 2.0 2.0 1.5 1.7 1.2 1.1 0.8 0.7 0.6 0.4 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.2 0.3 0.3 0.2 0.1 0.2 0.2 0.2 0.1 0.0 0.0 0.00.00.1 0.1 0.1 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.00.10.10.20.20.20.20.20.30.40.40.40.20.20.20.20.20.20.20.30.40.40.40.20.20.1 0.2 0.30.30.20.20.20.20.10.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.5 0.7 0.7 0.6 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.5 1.0 1.9 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.8 1.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.3 Luminaire Schedule Symbol Qty Label Arrangement Lum. Lumens LLF Description 2 LH-4 SINGLE 12560 0.950 CBMC DL00103435 VERIFY COLOR AND VOLTAGE 2 L-4 SINGLE 15535 0.950 CBMC DL103444 VERIFY COLOR AND VOLTAGE 2 L5 SINGLE 15674 0.950 CBMC DL103592 VERIFY COLOR AND VOLTAGE 2 LH-4a 2 @ 90 DEGREES 12560 0.950 CBMC DL00103435 VERIFY COLOR AND VOLTAGE Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min ALL POINTS Illuminance Fc 2.41 10.0 0.1 24.10 100.00 PROPERTY LINE Illuminance Fc 0.13 0.4 0.0 N.A.N.A. SIDEWALKS Illuminance Fc 0.24 1.9 0.0 N.A.N.A. Based on the information provided, all dimensions and luminaire locations shown represent recommended positions. The engineer and/or architect must determine applicability of the layout to existing or future field conditions. This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with Illuminating Engineering Society approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps, and other variable field conditions. PHOTOMETRIC NOTES MOUNTING HEIGHT 25' -0" A.F.F. LIGHT LOSS FACTOR .95 FOOTCANDLES CALCULATED AT GRADE FOR PRICING REQUESTS CONTACT RUSS MILLER: 317-780-8350 rmiller@cbmcinc.com 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 APP R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 5855 KOPETSKY DR, SUITE G INDIANAPOLIS, IN 46217 317-780-8350 C900 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 APP R O V A L P E N D I N G NO T F O R C O N S T R U C T I O N 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 Based on the information provided, all dimensions and luminaire locations shown represent recommended positions. The engineer and/or architect must determine applicability of the layout to existing or future field conditions. This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with Illuminating Engineering Society approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps, and other variable field conditions. PHOTOMETRIC DETAILS MOUNTING HEIGHT LIGHT LOSS FACTOR FOOTCANDLES CALCULATED AT FOR PRICING REQUESTS CONTACT RUSS MILLER: 317-780-8350 rmiller@cbmcinc.com 5855 KOPETSKY DR, SUITE G INDIANAPOLIS, IN 46217 317-780-8350 C901 FUTURE TOWNHOUSES FUTURE TOWNHOUSES FU T U R E T O W N H O U S E S FU T U R E T O W N H O U S E S FU T U R E T O W N H O U S E S GR A N D B L V D MAIN STREET (10)Bux-g (60)Heu-a(48)Lir-s (7)Ite-v (9)Hyd-w (44)Heu-a (168)Iri-c (15)Bux-g (9)Deu-g (9)Spo-h (5)Cor-s (57)Iri-c (7)Pan-v (39)Ach-m (5)Car-c (7)Pan-v (141)Ech-x (10)Bux-x (14)Cal-k (10)Fot-g (29)Rud-h (1)Ulm-a (17)Rhu-g (31)Pan-v (1)Lir-t (2)Lir-t (6)Jun-c (1)Gle-x (1)Gle-x (6)Jun-c (2)Gle-x (12)Jun-c (80)Lir-s (14)Hyd-w (8)Bux-g (33)Nep-x (4)Cor-s (25)Nep-x (8)Pan-v (10)Fot-g (29)Rud-h (14)Cal-k (10)Bux-x (95)Ech-x (5)Car-c (57)Ach-m (17)Rhu-g (1)Ulm-a (1)Ulm-a (1)Gle-x (1)Gle-x (6)Jun-c (4)Jun-c (1)Ulm-a (1)Ulm-a (13)Phy-d (135)Lir-s (24)Ile-x (4)Ile-v (2)Ile-v (6)Ile-x Mulch or Groundcover Mulch or Groundcover Mulch or Groundcover Mulch or Groundcover (14)Jun-c (1)Ulm-a (6)Jun-c (13)Vib-b 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 0 Scale 1" = 20'-0" 402010 North 1.Plant material to be installed and maintained by a qualified and experienced landscape installer. 2.All materials are subject to the approval of the Landscape Architect and Owner at any time. Landscape Architect to inspect all plant locations and plant bed conditions prior to installation. Stake all plant locations for review and approval by the Landscape Architect before planting. On-site adjustments may be required. Plants are to be freshly dug. Transporting of plants shall be done in a manner as to not destroy the natural shape, compromise the health, or alter the characteristics of plant materials. 3.Rootballs shall meet or exceed size standards as set forth in 'American Standards for Nursery Stock'. MAIN LEADERS OF ALL TREES SHALL REMAIN INTACT. Remove from the site any plant material that turns brown or defoliates within five (5) days after planting. Replace immediately with approved, specified material. 4.Plant counts indicated on drawings are for Landscape Architect's use only. Contractor shall make own plant quantity takeoffs using drawings, specifications, and plant schedule requirements (i.e., spacing), unless otherwise directed by Landscape Architect. Contractor to verify bed measurements and install appropriate quantities as governed by plant spacing per schedule. 5.All plant beds shall receive 3" minimum of genuine shredded hardwood bark mulch (unless otherwise noted). Apply pre-emergent herbicide as directed by the manufacturer prior to installing mulch. Seed all areas disturbed by construction activities that are not otherwise noted to receive pavement, planting bed, or other treatment. 6.The Contractor shall install and/or amend topsoil in all proposed bed areas to meet ASTM D5268 standards. Landscaper shall verify depth and quality of topsoil prior to plant installation. A minimum of 4" of topsoil is required for lawn areas; 12" for plant beds. Topsoil sources shall include the reuse of surface soil stockpiled on site, clean of roots, plants, sod, stones, clay lumps, and other extraneous or foreign materials larger than 1". Supplement with imported topsoil from off-site sources when quantities are insufficient. Do not obtain supplemental topsoil from agricultural land, bogs, or marshes. Inorganic amendments, organic amendments, and fertilizers shall be used to amend topsoil as needed for long-term plant health. 7.Verify all utility locations in the field prior to beginning work. Repair all damaged utilities to satisfaction of the Owner and Operating Authority at no additional cost. 8.Install all plant material in accordance with all local codes and ordinances. Coordinate with the Owner to obtain any required permits necessary to complete work. All workmanship and materials shall be guaranteed by the Contractor for a period of one (1) calendar year after Final Acceptance. 9.Maintain all plant material for a three (3) month period from date of Substantial Completion. Maintenance shall include pruning, cultivating, watering, weeding, fertilizing, restoring plant saucers, spraying for disease and insects, and replacing tree wrappings. Recommended long-term maintenance procedures shall be provided to the Owner before expiration of this period. 10.Satisfactory Seeded Lawn: At end of maintenance period, a healthy, uniform, close stand of grass has been established, free of weeds and surface irregularities, with coverage exceeding 90 percent over any 10 sq. ft. (0.92 sq. m) and bare spots not exceeding 3 by 3 inches.Reestablish lawns that do not comply with requirements and continue maintenance until lawns are fully satisfactory to the Owner. GENERAL LANDSCAPE AND PLANTING NOTES L100 PLANTING PLAN LANDSCAPE ORDINANCE REQUIREMENTS Zoned: PUD Street Trees - Provided in previous project Foundation Planting Required: planting beds @ 5' minimum depth. Maximum 5' spacing. 75% of beds planted. Parking Lot Interior Planting - 106 Spaces Required: (1) Shade Tree + (5) Shrubs/every (10) Spaces Provided: (11) Shade Trees + (53) Shrubs Parking Lot Perimeter Planting Required: (4) Shade Trees + (20) Shrubs/100lf West Edge - 20 l.f. + 57 l.f. Provided: (3) Shade + (14) Shrubs North Edge - 22 l.f. Provided: (1) Shade + (5) Shrubs East Edge - Not Required South Edge - Not Required NOTE: LANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET L101 - SEE PLANTING DETAILS. Area to receive lawn LANDSCAPE HATCH LEGEND 7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 2014.02691 02/16/2015 DESIGN FAIRFIELD INN AND SUITES BY MARRIOTT @ GRAND & MAIN MAIN STREET & GRAND BOULEVARD, CARMEL, IN. 46032 L101 PLANTING DETAILS GROUNDCOVER PLANTING Not to Scale Note: All groundcover beds shall be planted using triangular planting scheme. Refer to Planting Schedule for On-Center planting dimension. Refer to Plans for Finish Grade. 3" Shredded Hardwood Bark Mulch Split Peat Pot 12" Prepared Soil; Refer to Specifications Compacted Subgrade PERENNIAL PLANTING Not to Scale Note: All perennial beds shall be planted using triangular planting scheme. Refer to Planting Schedule for On-Center planting dimension. 3" Shredded Hardwood Bark Mulch Remove Container 12" Prepared Soil; Refer to Specifications Compacted Subgrade Existing Grade NOTE: LANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON THIS SHEET. SPADE EDGE Not to Scale Existing Grade Area to Receive Hardwood Bark Mulch Topsoil (As Specified) 5" 3" 3"