Loading...
HomeMy WebLinkAboutRepublic_HotelAdd-ADLS _ARCH AND LA DWGS 14A. REFER TO DRAWING SET OF EXISTING REPUBLIC HOTEL PROJECT FOR TYPICAL WALL TYPES FOR TYPICAL HOTEL UNIT WALLS B. REFERENCE A-001 AND A-002 FOR GENERAL ARCHITECTURAL NOTES AND PARTITION STANDARDS. C. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E. 1001-1. REFERENCE SPECIFICATIONS FOR ATYPICAL DOORS TO EXISTING HOTEL. D. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALL UNLESS NOTED OTHERWISE E. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS TO INSURE PROPER ROUGH-IN CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE. F. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS GYPSUM BOARD AND MASONRY, MASONRY AND CONCRETE, COUNTERTOPS AND WALL, ETC. G. PROVIDE BLOCKING IN GUESTROOMS AT ALL LOCATIONS WHERE CASEGOODS ARE SPECIFIED TO BE ANCHORED AT THE WALL. REFERENCE ECISTING HOTEL ARCHITECTURAL DRAWINGS AND FFE PACKAGE FOR SPECIFICATIONS. H. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION UNLESS OTHERWISE INDICATED. I. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW AND STOREFRONT FRAME PERIMETERS AND SURROUNDING CONSTRUCTION UNLESS OTHERWISE INDICATED. J. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL SHEETS FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING NECESSARY FRAMING, BLOCKING, ETC. K. PROVIDE MINIMUM CLEARANCES AT ALL DOORS AND CORRIDORS PER ADA REQUIREMENTS. L. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING SCOPE OF WORK, AND REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION. M. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL DIMENSIONS. N. MATCH EXISTING WAYFINDING, INFORMATIONAL, AND CODE REQUIRED SIGNAGE SPECIFICATIONS FOR ALL PUBLIC SPACE, BACK OF HOUSE, GUESTROOMS, AND EXTERIOR BUILDING SIGNAGE. O. REFERENCE ROOM FFE PACKAGE FOR ALL WINDOW TREATMENTS IN GUEST ROOMS. REFERENCE EXISTING HOTEL DRAWINGS FOR WINDOW TREATMENTSIN LOUNGE SPACES. P. ALL PUBLIC SPACE CONCRETE COLUMNS TO RECIEVE GYP FURRING. B B 6 6 5 5 4 4 3 3 2 2 C C D D E E A-201 A1 6.H6.H 5.H5.H 4.H4.H 3.H3.H 2.H2.H A.H A.H 1.H1.H B.H B.H C.H C.H D.H D.H 2389 SF TENANT 2 T2 728 SF TRASH / SERVICE 111 SERVICE DOCK A-202 D1 A1 A-321 A3 A-321 A4 A-321 B1 A-301 A1 A-323 1.5.H1.5.H A2 A-324 A4 A-324 GRAY SHELL -NO SLAB 262 SF PLUMBING 112 134 SF ELECTRICAL 113 326 SF CORRIDOR 110 EXST MECH SHAFT 3-YD DUMPSTERS (OFOI) M8A.D M8A.D M8A.D DEMO OPENING IN EXISTING FOR NEW DOOR EXISTING 2-HOUR RATED WALL M8A.D.1 M8A.D.1 M8A.D.1 M8A.D.1 180 MIN RATED DOOR (TYP FOR ALL DOORS PASSING THROUGH SEPARATION BETWEEN EXST. GARAGE AND NEW HOTEL / RETAIL 17'-8 3/8" 15 ' - 0 3 / 8 " 16 ' - 3 3 / 8 " ROLLING OH DOOR REFER TO L-SERIES FOR SITE DESIGN GRAY SHELL -NO SLAB EXST. GARAGE ASSUME (1) 3'6" W X 9' H DOOR PER STOREFRONTS INDICATED A1 A-301 4937 SF TENANT 1 T1 756 SF CORRIDOR 101 S6A.D EXTERIOR WALL ASSEMBLY 02-A 1 A-324 A3 A-323 A6 A-322 2' - 0 5 / 8 " 2'-0 5/8" 2' - 0 5 / 8 " A5 A-323 2 A-302 1 A-302 A-355 C1 A-355 A1 A-355 C6 A-355 E6 W01 A-203A1 A-203 F1 E1 AP-X06 1 AP-X04 1 A. THESE NOTES APPLY TO ARCHITECTURAL DRAWINGS. B. EXTERIOR WALL ASSEMBLIES a. *ALL EXTERIOR CLADDING FINISHES ARE INTENDED TO MATCH THOSE SHOWN ON THE EXISTING REPUBLIC HOTEL PROJECT. REFER TO THOSE DRAWINGS FOR REFERENCE* b. EXTERIOR WALL ASSEMBLY 01-A • (EXTERIOR FINISH) • FORMED METAL PANEL WITH 3-COAT FLUOROPOLYMER FINISH, COLOR TO MATCH ARCHITECT'S SAMPLE (BOD: CENTRIA CONCEPT SERIES CS-220 OR COMPARABLE PRODUCT) • SUBFRAMING PER MANUF. REQUIREMENTS • 3" CONTINUOUS INSULATION (MINERAL-WOOL BOARD) • FLUID-APPLIED MEMBRANE AIR BARRIER • 5/8" GLASS-MAT GYPSUM SHEATHING • 6" COLD FORM STUD FRAMING • 5/8" GYPSUM WALL BOARD • (INTERIOR FINISH) c. EXTERIOR WALL ASSEMBLY 01-B (GARAGE CLADDING ONLY) • (EXTERIOR FINISH) • FORMED METAL PANEL WITH 3-COAT FLUOROPOLYMER FINISH, COLOR TO MATCH ARCHITECT'S SAMPLE (BOD: CENTRIA CONCEPT SERIES CS-220 OR COMPARABLE PRODUCT) • SUBFRAMING PER MANUF. REQUIREMENTS • 6" COLD FORM STUD FRAMING • PROVIDE FRAMING CLIPS FOR ATTACHMENT BACK TO EXISTING GARAGE STRUCTURE (CIP CONCRETE OR CMU) • (NO INTERIOR FINISH) d. EXTERIOR WALL ASSEMBLY 01-C (GARAGE CLADDING ONLY) • (EXTERIOR FINISH) • FORMED METAL PANEL WITH 3-COAT FLUOROPOLYMER FINISH, COLOR TO MATCH ARCHITECT'S SAMPLE (BOD: CENTRIA CONCEPT SERIES CS-220 OR COMPARABLE PRODUCT) • SUBFRAMING PER MANUF. REQUIREMENTS • EXISTING STRUCTURE (CMU OR CIP CONCRETE) • (NO INTERIOR FINISH) e. EXTERIOR WALL ASSEMBLY 02-A (HOTEL ONLY) • (EXTERIOR FINISH) • 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL ONLY) • MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY YANKEE HILL) • ~2" AIR GAP • 3" CONTINUOUS INSULATION (MINERAL-WOOL BOARD) • FLUID-APPLIED MEMBRANE AIR BARRIER • 5/8" GLASS-MAT GYPSUM SHEATHING • 8" COLD FORM STUD FRAMING • 5/8" GYPSUM WALL BOARD • (INTERIOR FINISH) f. EXTERIOR WALL ASSEMBLY 02-B (GARAGE CLADDING ONLY) • (EXTERIOR FINISH) • 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL ONLY) • MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY YANKEE HILL) • ~2" AIR GAP • 8" CMU • (NO INTERIOR FINISH) g. EXTERIOR WALL ASSEMBLY 02-C • (EXTERIOR FINISH) • 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL ONLY) • MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY YANKEE HILL) • ~2" AIR GAP • EXISTING STRUCTURE (CMU OR CIP CONCRETE) • (NO INTERIOR FINISH) h. EXTERIOR WALL ASSEMBLY 02-D (GARAGE CLADDING ONLY) • (EXTERIOR FINISH) • 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL ONLY) • MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY YANKEE HILL) • ~2" AIR GAP • INFILL WITH 8" CMU BETWEEN EXISTING GARAGE STRUCTURE AS NEEDED FOR STRUCTURAL BACKUP • (NO INTERIOR FINISH) A. BASE BID: FULL FIT OUT AS SHOWN IN THE DD PRICING DOCUMENTS B. ALTERNATE NO.1: PRICE AS A DEDUCT TO SHELL OUT THE THIRD HOTEL FLOOR IN ITS ENTIRETY. PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT C. ALTERNATE NO.2: PRICE AS A DEDUCT TO SHELL OUT THE THIRD AND FOURTH HOTEL FLOORS IN THEIR ENTIRETY. PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT SHEET TITLE SHEET NUMBER Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect O'Donnell & Naccarato Structural Engineer Mechanical / Electrical/ Plumbing Engineer Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 Three Parkwood Crossing 450 East 96th Street, Suite 175 Indianapolis, IN 46240 317-580-0402 CIRCLE DESIGN GROUP 9229 Delegates Row #150 Indianapolis, Indiana 46240 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. IT / Technology DESIGN 27 1650 East 49th Street Indianapolis, IN 46205 (317) 536-8000 Acoustics Jaffe Holden 114-A Washington Street Norwalk, Connecticut 06854 (203) 838-4167 4/ 1 8 / 2 0 2 5 3 : 2 6 : 0 7 P M A-101A FIRST FLOOR PLAN - NORTH 24220.000 REPUBLIC HOTEL ADDITION 12201 N. Meridian Street Carmel, Indiana 46032 KEYNOTES (SPEC BASED) GENERAL FLOOR PLAN NOTES 1/8" = 1'-0"A-101A A2 FIRST LEVEL FLOOR PLAN (NORTH) GENERAL EXTERIOR DESIGN NOTES 1 SD PRICING SET 02/21/25 2 DESIGN DEVELOPMENT 04/18/25 04/18/25 ALTERNATE NOTES FOR PRICING