HomeMy WebLinkAboutRepublic_HotelAdd-ADLS _ARCH AND LA DWGS 14A. REFER TO DRAWING SET OF EXISTING REPUBLIC HOTEL
PROJECT FOR TYPICAL WALL TYPES FOR TYPICAL HOTEL
UNIT WALLS
B. REFERENCE A-001 AND A-002 FOR GENERAL
ARCHITECTURAL NOTES AND PARTITION STANDARDS.
C. DOOR AND FRAME NUMBERS CORRESPOND TO
RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE
OPENINGS A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS,
I.E. 1001-1. REFERENCE SPECIFICATIONS FOR ATYPICAL
DOORS TO EXISTING HOTEL.
D. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES
FROM FINISH FACE OF ADJACENT WALL UNLESS NOTED
OTHERWISE
E. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS
AND SUPPLIERS TO INSURE PROPER ROUGH-IN
CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE.
F. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH
AS GYPSUM BOARD AND MASONRY, MASONRY AND
CONCRETE, COUNTERTOPS AND WALL, ETC.
G. PROVIDE BLOCKING IN GUESTROOMS AT ALL LOCATIONS
WHERE CASEGOODS ARE SPECIFIED TO BE ANCHORED AT
THE WALL. REFERENCE ECISTING HOTEL ARCHITECTURAL
DRAWINGS AND FFE PACKAGE FOR SPECIFICATIONS.
H. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME
PERIMETERS AND SURROUNDING WALL CONSTRUCTION
UNLESS OTHERWISE INDICATED.
I. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR
WINDOW AND STOREFRONT FRAME PERIMETERS AND
SURROUNDING CONSTRUCTION UNLESS OTHERWISE
INDICATED.
J. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL SHEETS FOR COORDINATION ITEMS.
COORDINATE AS REQUIRED INCLUDING NECESSARY
FRAMING, BLOCKING, ETC.
K. PROVIDE MINIMUM CLEARANCES AT ALL DOORS AND
CORRIDORS PER ADA REQUIREMENTS.
L. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING
SCOPE OF WORK, AND REPORT DISCREPANCIES
IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
M. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL
DIMENSIONS.
N. MATCH EXISTING WAYFINDING, INFORMATIONAL, AND CODE
REQUIRED SIGNAGE SPECIFICATIONS FOR ALL PUBLIC
SPACE, BACK OF HOUSE, GUESTROOMS, AND EXTERIOR
BUILDING SIGNAGE.
O. REFERENCE ROOM FFE PACKAGE FOR ALL WINDOW
TREATMENTS IN GUEST ROOMS. REFERENCE EXISTING
HOTEL DRAWINGS FOR WINDOW TREATMENTSIN LOUNGE
SPACES.
P. ALL PUBLIC SPACE CONCRETE COLUMNS TO RECIEVE GYP
FURRING.
B
B
6 6
5 5
4 4
3 3
2 2
C
C
D
D
E
E
A-201 A1
6.H6.H
5.H5.H
4.H4.H
3.H3.H
2.H2.H
A.H
A.H
1.H1.H
B.H
B.H
C.H
C.H
D.H
D.H
2389 SF
TENANT 2
T2
728 SF
TRASH /
SERVICE
111
SERVICE
DOCK
A-202
D1
A1
A-321
A3
A-321
A4
A-321
B1
A-301
A1
A-323
1.5.H1.5.H
A2
A-324
A4
A-324
GRAY SHELL -NO SLAB
262 SF
PLUMBING
112
134 SF
ELECTRICAL
113
326 SF
CORRIDOR
110
EXST MECH
SHAFT
3-YD DUMPSTERS (OFOI)
M8A.D
M8A.D
M8A.D
DEMO OPENING IN EXISTING FOR NEW DOOR
EXISTING 2-HOUR RATED WALL
M8A.D.1
M8A.D.1
M8A.D.1
M8A.D.1
180 MIN RATED DOOR (TYP FOR ALL DOORS
PASSING THROUGH SEPARATION BETWEEN
EXST. GARAGE AND NEW HOTEL / RETAIL
17'-8 3/8"
15
'
-
0
3
/
8
"
16
'
-
3
3
/
8
"
ROLLING OH DOOR
REFER TO L-SERIES FOR SITE DESIGN
GRAY SHELL -NO SLAB
EXST. GARAGE
ASSUME (1) 3'6" W X 9' H
DOOR PER STOREFRONTS
INDICATED
A1
A-301
4937 SF
TENANT 1
T1
756 SF
CORRIDOR
101
S6A.D
EXTERIOR WALL ASSEMBLY
02-A
1
A-324
A3
A-323
A6
A-322
2'
-
0
5
/
8
"
2'-0 5/8"
2'
-
0
5
/
8
"
A5
A-323
2
A-302
1
A-302
A-355
C1
A-355
A1
A-355
C6
A-355
E6
W01
A-203A1
A-203
F1
E1
AP-X06 1
AP-X04
1
A. THESE NOTES APPLY TO ARCHITECTURAL DRAWINGS.
B. EXTERIOR WALL ASSEMBLIES
a. *ALL EXTERIOR CLADDING FINISHES ARE INTENDED TO
MATCH THOSE SHOWN ON THE EXISTING REPUBLIC
HOTEL PROJECT. REFER TO THOSE DRAWINGS FOR
REFERENCE*
b. EXTERIOR WALL ASSEMBLY 01-A
• (EXTERIOR FINISH)
• FORMED METAL PANEL WITH 3-COAT
FLUOROPOLYMER FINISH, COLOR TO MATCH
ARCHITECT'S SAMPLE (BOD: CENTRIA CONCEPT
SERIES CS-220 OR COMPARABLE PRODUCT)
• SUBFRAMING PER MANUF. REQUIREMENTS
• 3" CONTINUOUS INSULATION (MINERAL-WOOL BOARD)
• FLUID-APPLIED MEMBRANE AIR BARRIER
• 5/8" GLASS-MAT GYPSUM SHEATHING
• 6" COLD FORM STUD FRAMING
• 5/8" GYPSUM WALL BOARD
• (INTERIOR FINISH)
c. EXTERIOR WALL ASSEMBLY 01-B (GARAGE CLADDING
ONLY)
• (EXTERIOR FINISH)
• FORMED METAL PANEL WITH 3-COAT
FLUOROPOLYMER FINISH, COLOR TO MATCH
ARCHITECT'S SAMPLE (BOD: CENTRIA CONCEPT
SERIES CS-220 OR COMPARABLE PRODUCT)
• SUBFRAMING PER MANUF. REQUIREMENTS
• 6" COLD FORM STUD FRAMING
• PROVIDE FRAMING CLIPS FOR ATTACHMENT BACK TO
EXISTING GARAGE STRUCTURE (CIP CONCRETE OR
CMU)
• (NO INTERIOR FINISH)
d. EXTERIOR WALL ASSEMBLY 01-C (GARAGE CLADDING
ONLY)
• (EXTERIOR FINISH)
• FORMED METAL PANEL WITH 3-COAT
FLUOROPOLYMER FINISH, COLOR TO MATCH
ARCHITECT'S SAMPLE (BOD: CENTRIA CONCEPT
SERIES CS-220 OR COMPARABLE PRODUCT)
• SUBFRAMING PER MANUF. REQUIREMENTS
• EXISTING STRUCTURE (CMU OR CIP CONCRETE)
• (NO INTERIOR FINISH)
e. EXTERIOR WALL ASSEMBLY 02-A (HOTEL ONLY)
• (EXTERIOR FINISH)
• 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL
ONLY)
• MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY
YANKEE HILL)
• ~2" AIR GAP
• 3" CONTINUOUS INSULATION (MINERAL-WOOL BOARD)
• FLUID-APPLIED MEMBRANE AIR BARRIER
• 5/8" GLASS-MAT GYPSUM SHEATHING
• 8" COLD FORM STUD FRAMING
• 5/8" GYPSUM WALL BOARD
• (INTERIOR FINISH)
f. EXTERIOR WALL ASSEMBLY 02-B (GARAGE CLADDING
ONLY)
• (EXTERIOR FINISH)
• 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL
ONLY)
• MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY
YANKEE HILL)
• ~2" AIR GAP
• 8" CMU
• (NO INTERIOR FINISH)
g. EXTERIOR WALL ASSEMBLY 02-C
• (EXTERIOR FINISH)
• 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL
ONLY)
• MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY
YANKEE HILL)
• ~2" AIR GAP
• EXISTING STRUCTURE (CMU OR CIP CONCRETE)
• (NO INTERIOR FINISH)
h. EXTERIOR WALL ASSEMBLY 02-D (GARAGE CLADDING
ONLY)
• (EXTERIOR FINISH)
• 2" THICK GRANITE BASE, 8" HEIGHT (BASE OF WALL
ONLY)
• MODULAR BRICK (BOD: DARK IRON SPOT SMOOTH BY
YANKEE HILL)
• ~2" AIR GAP
• INFILL WITH 8" CMU BETWEEN EXISTING GARAGE
STRUCTURE AS NEEDED FOR STRUCTURAL BACKUP
• (NO INTERIOR FINISH)
A. BASE BID: FULL FIT OUT AS SHOWN IN THE DD PRICING
DOCUMENTS
B. ALTERNATE NO.1: PRICE AS A DEDUCT TO SHELL OUT THE
THIRD HOTEL FLOOR IN ITS ENTIRETY. PROVIDE METAL
STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL
FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT
C. ALTERNATE NO.2: PRICE AS A DEDUCT TO SHELL OUT THE
THIRD AND FOURTH HOTEL FLOORS IN THEIR ENTIRETY.
PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO
DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT
SHEET TITLE
SHEET NUMBER
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
O'Donnell & Naccarato
Structural Engineer
Mechanical / Electrical/ Plumbing Engineer
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
Three Parkwood Crossing
450 East 96th Street, Suite 175
Indianapolis, IN 46240
317-580-0402
CIRCLE DESIGN GROUP
9229 Delegates Row #150
Indianapolis, Indiana 46240
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
IT / Technology
DESIGN 27
1650 East 49th Street
Indianapolis, IN 46205
(317) 536-8000
Acoustics
Jaffe Holden
114-A Washington Street
Norwalk, Connecticut 06854
(203) 838-4167
4/
1
8
/
2
0
2
5
3
:
2
6
:
0
7
P
M
A-101A
FIRST FLOOR PLAN -
NORTH
24220.000
REPUBLIC
HOTEL
ADDITION
12201 N. Meridian
Street
Carmel, Indiana
46032
KEYNOTES (SPEC BASED)
GENERAL FLOOR PLAN NOTES
1/8" = 1'-0"A-101A
A2 FIRST LEVEL FLOOR PLAN (NORTH)
GENERAL EXTERIOR DESIGN NOTES
1 SD PRICING SET 02/21/25
2 DESIGN DEVELOPMENT 04/18/25
04/18/25
ALTERNATE NOTES FOR PRICING