HomeMy WebLinkAboutRepublic_HotelAdd-ADLS _ARCH AND LA DWGS 15A. REFER TO DRAWING SET OF EXISTING REPUBLIC HOTEL PROJECT FOR TYPICAL WALL TYPES FOR TYPICAL HOTEL UNIT WALLS B. REFERENCE A-001 AND A-002 FOR GENERAL ARCHITECTURAL NOTES AND PARTITION STANDARDS. C. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E. 1001-1. REFERENCE SPECIFICATIONS FOR ATYPICAL DOORS TO EXISTING HOTEL. D. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALL UNLESS NOTED OTHERWISE E. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS TO INSURE PROPER ROUGH-IN CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE. F. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS GYPSUM BOARD AND MASONRY, MASONRY AND CONCRETE, COUNTERTOPS AND WALL, ETC. G. PROVIDE BLOCKING IN GUESTROOMS AT ALL LOCATIONS WHERE CASEGOODS ARE SPECIFIED TO BE ANCHORED AT THE WALL. REFERENCE ECISTING HOTEL ARCHITECTURAL DRAWINGS AND FFE PACKAGE FOR SPECIFICATIONS. H. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION UNLESS OTHERWISE INDICATED. I. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW AND STOREFRONT FRAME PERIMETERS AND SURROUNDING CONSTRUCTION UNLESS OTHERWISE INDICATED. J. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL SHEETS FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING NECESSARY FRAMING, BLOCKING, ETC. K. PROVIDE MINIMUM CLEARANCES AT ALL DOORS AND CORRIDORS PER ADA REQUIREMENTS. L. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING SCOPE OF WORK, AND REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION. M. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL DIMENSIONS. N. MATCH EXISTING WAYFINDING, INFORMATIONAL, AND CODE REQUIRED SIGNAGE SPECIFICATIONS FOR ALL PUBLIC SPACE, BACK OF HOUSE, GUESTROOMS, AND EXTERIOR BUILDING SIGNAGE. O. REFERENCE ROOM FFE PACKAGE FOR ALL WINDOW TREATMENTS IN GUEST ROOMS. REFERENCE EXISTING HOTEL DRAWINGS FOR WINDOW TREATMENTSIN LOUNGE SPACES. P. ALL PUBLIC SPACE CONCRETE COLUMNS TO RECIEVE GYP FURRING. 10 10 B B 9 9 8 8 7 7 C C D D E E 11 11 12 12 A-201 A1 8.H8.H 7.H7.H 6.H6.H 9.H9.H A.H A.H B.H B.H C.H C.H D.H D.H 4937 SF TENANT 1 T1 423 SF ELEVATOR LOBBY 100A 73 SF IDF 103 756 SF CORRIDOR 101 387 SF LAUNDRY 102 121 SF ELEVATORS E1 A-420 D2 B6 A-420 B4 A-420 A4 A-321 A6 A-321 B1 A-301 A6 A-324 GRAY SHELL -NO SLAB MECH CHASE ABOVE DEMO 8' H OPENING IN EXST WALL M8A.D DEMO EXISTING DOUBLE DOOR AND INFILL TO MATCH EXISTING WALL (CMU) DEMO OPENING IN EXISTING WALL FOR NEW DOOR (3-HR RATED) S6X.D.1.A S6A.D S6A.D.A EXISTING GARAGE STRUCTURE. INFILL BETWEEN EXISTING CIP WITH M8A-2H (TYPICAL FOR SEPARATING WALLS BETWEEN EXISTING GARAGE AND NEW HOTEL / RETAIL 132 SF VESTIBULE 100 SLIDING VESTIBULE DOORS - MATCH EXISTING HOTEL 084113.B03 FUTURE ELEVATOR / NOT IN SCOPE EXISTING GARAGE EXST. COLUMNS, TYP. MATCH EXISTING HOTEL VESTIBULE A1 A-322 2 A-302 A-355 C3 A-355 A3 A-355 A6 W01 W01 W01 A-203 A4 AP-X06 1 BRICK RETURNS BACK TO CURTAIN WALL, TYPICAL AT ALL RETAIL OPENINGS SIM A. BASE BID: FULL FIT OUT AS SHOWN IN THE DD PRICING DOCUMENTS B. ALTERNATE NO.1: PRICE AS A DEDUCT TO SHELL OUT THE THIRD HOTEL FLOOR IN ITS ENTIRETY. PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT C. ALTERNATE NO.2: PRICE AS A DEDUCT TO SHELL OUT THE THIRD AND FOURTH HOTEL FLOORS IN THEIR ENTIRETY. PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT SHEET TITLE SHEET NUMBER Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect O'Donnell & Naccarato Structural Engineer Mechanical / Electrical/ Plumbing Engineer Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 Three Parkwood Crossing 450 East 96th Street, Suite 175 Indianapolis, IN 46240 317-580-0402 CIRCLE DESIGN GROUP 9229 Delegates Row #150 Indianapolis, Indiana 46240 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. IT / Technology DESIGN 27 1650 East 49th Street Indianapolis, IN 46205 (317) 536-8000 Acoustics Jaffe Holden 114-A Washington Street Norwalk, Connecticut 06854 (203) 838-4167 4/ 1 8 / 2 0 2 5 3 : 2 6 : 1 0 P M A-101B FIRST FLOOR PLAN - SOUTH 24220.000 REPUBLIC HOTEL ADDITION 12201 N. Meridian Street Carmel, Indiana 46032 KEYNOTES (SPEC BASED) 084113.B03 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS - EXTERIOR, 6" FRAME DEPTH GENERAL FLOOR PLAN NOTES 1/8" = 1'-0"A-101B A2 FIRST LEVEL FLOOR PLAN (SOUTH) 1 SD PRICING SET 02/21/25 2 DESIGN DEVELOPMENT 04/18/25 04/18/25 ALTERNATE NOTES FOR PRICING