HomeMy WebLinkAboutRepublic_HotelAdd-ADLS _ARCH AND LA DWGS 19UP A. REFER TO DRAWING SET OF EXISTING REPUBLIC HOTEL PROJECT FOR TYPICAL WALL TYPES FOR TYPICAL HOTEL UNIT WALLS B. REFERENCE A-001 AND A-002 FOR GENERAL ARCHITECTURAL NOTES AND PARTITION STANDARDS. C. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E. 1001-1. REFERENCE SPECIFICATIONS FOR ATYPICAL DOORS TO EXISTING HOTEL. D. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALL UNLESS NOTED OTHERWISE E. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS TO INSURE PROPER ROUGH-IN CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE. F. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS GYPSUM BOARD AND MASONRY, MASONRY AND CONCRETE, COUNTERTOPS AND WALL, ETC. G. PROVIDE BLOCKING IN GUESTROOMS AT ALL LOCATIONS WHERE CASEGOODS ARE SPECIFIED TO BE ANCHORED AT THE WALL. REFERENCE ECISTING HOTEL ARCHITECTURAL DRAWINGS AND FFE PACKAGE FOR SPECIFICATIONS. H. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION UNLESS OTHERWISE INDICATED. I. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW AND STOREFRONT FRAME PERIMETERS AND SURROUNDING CONSTRUCTION UNLESS OTHERWISE INDICATED. J. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL SHEETS FOR COORDINATION ITEMS. COORDINATE AS REQUIRED INCLUDING NECESSARY FRAMING, BLOCKING, ETC. K. PROVIDE MINIMUM CLEARANCES AT ALL DOORS AND CORRIDORS PER ADA REQUIREMENTS. L. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING SCOPE OF WORK, AND REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION. M. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL DIMENSIONS. N. MATCH EXISTING WAYFINDING, INFORMATIONAL, AND CODE REQUIRED SIGNAGE SPECIFICATIONS FOR ALL PUBLIC SPACE, BACK OF HOUSE, GUESTROOMS, AND EXTERIOR BUILDING SIGNAGE. O. REFERENCE ROOM FFE PACKAGE FOR ALL WINDOW TREATMENTS IN GUEST ROOMS. REFERENCE EXISTING HOTEL DRAWINGS FOR WINDOW TREATMENTSIN LOUNGE SPACES. P. ALL PUBLIC SPACE CONCRETE COLUMNS TO RECIEVE GYP FURRING. 10 10 B B 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 C C D D E E 11 11 12 12 F F A-201 A1 8.H8.H 7.H7.H 6.H6.H 5.H5.H 4.H4.H 3.H3.H 2.H2.H 9.H9.H A.H A.H 1.H1.H B.H B.H C.H C.H D.H D.H A-202 A1 A1 A-323 1.5.H1.5.H A-201D1 A1 A-301 CORRIDOR 301 ELEC 301A IDF 301B LAUNDRY 301C ELEVATORS SHAFT TYPE 2 GUESTROOM 302 TYPE 2 GUESTROOM 304 TYPE 2 GUESTROOM 306 TYPE 2 GUESTROOM 308 TYPE 2 GUESTROOM 310 TYPE 2 GUESTROOM 312 TYPE 2 GUESTROOM 314 TYPE 2 GUESTROOM 316 TYPE 2 GUESTROOM 318 TYPE 2 GUESTROOM 320 TYPE 2 GUESTROOM 322 TYPE 2 GUESTROOM 324 TYPE 2 GUESTROOM 326 LOUNGE 340 TYPE 2 GUESTROOM 328 TYPE 2 GUESTROOM 330 TYPE 2 GUESTROOM 332 ADA GUESTROOM TYPE3, SIM 334 CORRIDOR 300 A A6 A-322 8'-4 7/8" 7' - 4 1 / 2 " 24'-9 1/8" 24 ' - 9 1 / 4 " 1'-11 1/4" ELEV LOBBY 300 A5 A-323 1 A-302 10 ' - 1 0 " 10 ' - 1 0 " 10 ' - 1 0 " 10 ' - 1 0 " 10 ' - 1 0 " 10 ' - 1 0 " A-501 E1F1 USL USL USL USL USL USL USL USL USL USL USL USL USL USL USL USL UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN UEN 301C 301B 301A301 340 USL A-203A1 A-203 A4 UEN A-401 C7 A-404 A4 A-403 A1 A-402 A5 STAIR 2 S-342 STAIR 1 S-341 1' - 0 1 / 4 " 13 ' - 5 " 11 ' - 3 " A4 / A 4 0 4 , T Y P 12 ' - 8 " R E F E R T O 12 ' - 8 " 1' - 0 " 12 ' - 8 " 12 ' - 8 " 1' - 0 " 12 ' - 8 " 12 ' - 8 " 1' - 0 " 12 ' - 8 " 12 ' - 8 " 1' - 0 " 12 ' - 8 " 12 ' - 8 " 1' - 0 " 12 ' - 8 " 12 ' - 8 " 1' - 0 " 12 ' - 8 " 15 ' - 0 1 5 / 3 2 " 2'-6 1/2"24'-0 1/2"8'-4 3/4"12'-8"12'-8"1'-0"12'-8"8'-4 3/8"1'-6"4'-8"3'-5 1/2" 5' - 0 1 / 8 " 28 ' - 3 1 / 4 " 21'-0 1/4"2'-9 1/2"12'-2"17'-8" 7' - 7 1 / 4 " 9' - 7 1 / 4 " 19 ' - 1 1 1 / 2 " 19 ' - 7 3 / 4 " 10 ' - 7 3 / 4 " 7' - 3 3 / 8 " 12 ' - 8 1 / 8 " 17 ' - 2 1 / 2 " 5' - 6 " 7'-5 3/8"4'-7 3/4" 5'-11 7/8" 3'-5 5/8"11'-8 1/8"5'-11 7/8"2'-11 5/8"18'-0 5/8" 2' - 1 1 5 / 8 " 11 ' - 5 5 / 8 " 2' - 1 1 5 / 8 " 2' - 0 1 / 2 " 26 ' - 5 5 / 8 " 1' - 9 5 / 8 " 2'-11 1/2"23'-7 1/2"5'-11"8'-4 3/4"17'-11 7/8" 8 1 1 / 3 2 " 5' - 1 1 / 8 " 9' - 3 " CORRIDOR 300 B CORRIDOR 300 C AP-X071 AP-X06 1 AP-X05 1 S1-3 S2-3 A. BASE BID: FULL FIT OUT AS SHOWN IN THE DD PRICING DOCUMENTS B. ALTERNATE NO.1: PRICE AS A DEDUCT TO SHELL OUT THE THIRD HOTEL FLOOR IN ITS ENTIRETY. PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT C. ALTERNATE NO.2: PRICE AS A DEDUCT TO SHELL OUT THE THIRD AND FOURTH HOTEL FLOORS IN THEIR ENTIRETY. PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT SHEET TITLE SHEET NUMBER Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect / Landscape Architect O'Donnell & Naccarato Structural Engineer Mechanical / Electrical/ Plumbing Engineer Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 Three Parkwood Crossing 450 East 96th Street, Suite 175 Indianapolis, IN 46240 317-580-0402 CIRCLE DESIGN GROUP 9229 Delegates Row #150 Indianapolis, Indiana 46240 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. IT / Technology DESIGN 27 1650 East 49th Street Indianapolis, IN 46205 (317) 536-8000 Acoustics Jaffe Holden 114-A Washington Street Norwalk, Connecticut 06854 (203) 838-4167 4/ 1 8 / 2 0 2 5 3 : 2 6 : 2 3 P M A-103 THIRD FLOOR PLAN - OVERALL 24220.000 REPUBLIC HOTEL ADDITION 12201 N. Meridian Street Carmel, Indiana 46032 KEYNOTES (SPEC BASED) GENERAL FLOOR PLAN NOTES 3/32" = 1'-0"A-103 A2 THIRD LEVEL FLOOR PLAN 1 SD PRICING SET 02/21/25 2 DESIGN DEVELOPMENT 04/18/25 04/18/25 ALTERNATE NOTES FOR PRICING