HomeMy WebLinkAboutRepublic_HotelAdd-ADLS _ARCH AND LA DWGS 21A. REFER TO DRAWING SET OF EXISTING REPUBLIC HOTEL
PROJECT FOR TYPICAL WALL TYPES FOR TYPICAL HOTEL
UNIT WALLS
B. REFERENCE A-001 AND A-002 FOR GENERAL
ARCHITECTURAL NOTES AND PARTITION STANDARDS.
C. DOOR AND FRAME NUMBERS CORRESPOND TO
RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE
OPENINGS A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS,
I.E. 1001-1. REFERENCE SPECIFICATIONS FOR ATYPICAL
DOORS TO EXISTING HOTEL.
D. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES
FROM FINISH FACE OF ADJACENT WALL UNLESS NOTED
OTHERWISE
E. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS
AND SUPPLIERS TO INSURE PROPER ROUGH-IN
CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE.
F. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH
AS GYPSUM BOARD AND MASONRY, MASONRY AND
CONCRETE, COUNTERTOPS AND WALL, ETC.
G. PROVIDE BLOCKING IN GUESTROOMS AT ALL LOCATIONS
WHERE CASEGOODS ARE SPECIFIED TO BE ANCHORED AT
THE WALL. REFERENCE ECISTING HOTEL ARCHITECTURAL
DRAWINGS AND FFE PACKAGE FOR SPECIFICATIONS.
H. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME
PERIMETERS AND SURROUNDING WALL CONSTRUCTION
UNLESS OTHERWISE INDICATED.
I. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR
WINDOW AND STOREFRONT FRAME PERIMETERS AND
SURROUNDING CONSTRUCTION UNLESS OTHERWISE
INDICATED.
J. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL SHEETS FOR COORDINATION ITEMS.
COORDINATE AS REQUIRED INCLUDING NECESSARY
FRAMING, BLOCKING, ETC.
K. PROVIDE MINIMUM CLEARANCES AT ALL DOORS AND
CORRIDORS PER ADA REQUIREMENTS.
L. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING
SCOPE OF WORK, AND REPORT DISCREPANCIES
IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
M. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL
DIMENSIONS.
N. MATCH EXISTING WAYFINDING, INFORMATIONAL, AND CODE
REQUIRED SIGNAGE SPECIFICATIONS FOR ALL PUBLIC
SPACE, BACK OF HOUSE, GUESTROOMS, AND EXTERIOR
BUILDING SIGNAGE.
O. REFERENCE ROOM FFE PACKAGE FOR ALL WINDOW
TREATMENTS IN GUEST ROOMS. REFERENCE EXISTING
HOTEL DRAWINGS FOR WINDOW TREATMENTSIN LOUNGE
SPACES.
P. ALL PUBLIC SPACE CONCRETE COLUMNS TO RECIEVE GYP
FURRING.
10 10
B
B
9 9
8 8
7 7
C
C
D
D
E
E
11 11
12 12
8.H8.H
7.H7.H
6.H6.H
9.H9.H
A.H
A.H
B.H
B.H
C.H
C.H
D.H
D.H
B6
A-420
B4
A-420
A4
A-321
A6
A-321
B1
A-301
A6
A-324
A1
A-322
TYPE 2
GUESTROOM
302
TYPE 2
GUESTROOM
304
TYPE 2
GUESTROOM
306
TYPE 2
GUESTROOM
308
TYPE 2
GUESTROOM
310
CORRIDOR
301
ELEC
301A
LAUNDRY
301C
2
A-302
A-203
A4
A-418
F4
ELEV LOBBY
300
ELEVATORS
E1 SHAFT
IDF
301B
STAIR 1
S-341
CORRIDOR
300 A
300
301C
301B
301 301A
492
198-4
493
USL
UEN
UEN
USL
USL
UEN
UEN
UEN
USL
USL
S1-3
UEN
A. BASE BID: FULL FIT OUT AS SHOWN IN THE DD PRICING
DOCUMENTS
B. ALTERNATE NO.1: PRICE AS A DEDUCT TO SHELL OUT THE
THIRD HOTEL FLOOR IN ITS ENTIRETY. PROVIDE METAL
STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL
FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT
C. ALTERNATE NO.2: PRICE AS A DEDUCT TO SHELL OUT THE
THIRD AND FOURTH HOTEL FLOORS IN THEIR ENTIRETY.
PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO
DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT
SHEET TITLE
SHEET NUMBER
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
O'Donnell & Naccarato
Structural Engineer
Mechanical / Electrical/ Plumbing Engineer
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
Three Parkwood Crossing
450 East 96th Street, Suite 175
Indianapolis, IN 46240
317-580-0402
CIRCLE DESIGN GROUP
9229 Delegates Row #150
Indianapolis, Indiana 46240
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
IT / Technology
DESIGN 27
1650 East 49th Street
Indianapolis, IN 46205
(317) 536-8000
Acoustics
Jaffe Holden
114-A Washington Street
Norwalk, Connecticut 06854
(203) 838-4167
4/
1
8
/
2
0
2
5
3
:
2
6
:
2
5
P
M
A-103B
THIRD FLOOR PLAN -
SOUTH
24220.000
REPUBLIC
HOTEL
ADDITION
12201 N. Meridian
Street
Carmel, Indiana
46032
KEYNOTES (SPEC BASED)
GENERAL FLOOR PLAN NOTES
1/8" = 1'-0"A-103B
A2 THIRD LEVEL FLOOR PLAN (SOUTH)
GENERAL NOTE: REFER TO SECOND FLOOR PLANS FOR
SIMILAR NOTES, WALL TYPES, DIMENSIONS AND
DETAILS. THE ONLY SIGNIFICANT DIFFERENCE BETWEEN
FLOOR 2 AND 3 IS THAT FLOOR 3 HAS AN ADDITIONAL
UNIT BETWEEN GRID 3.H AND 4.H
1 SD PRICING SET 02/21/25
2 DESIGN DEVELOPMENT 04/18/25
04/18/25
ALTERNATE NOTES FOR PRICING