HomeMy WebLinkAboutRepublic_HotelAdd-ADLS _ARCH AND LA DWGS 31S S
S
S S
A. REFER TO DRAWING SET OF EXISTING REPUBLIC HOTEL
PROJECT FOR TYPICAL WALL TYPES FOR TYPICAL HOTEL
UNIT WALLS
B. REFERENCE A-001 AND A-002 FOR GENERAL
ARCHITECTURAL NOTES AND PARTITION STANDARDS.
C. DOOR AND FRAME NUMBERS CORRESPOND TO
RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE
OPENINGS A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS,
I.E. 1001-1. REFERENCE SPECIFICATIONS FOR ATYPICAL
DOORS TO EXISTING HOTEL.
D. LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES
FROM FINISH FACE OF ADJACENT WALL UNLESS NOTED
OTHERWISE
E. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS
AND SUPPLIERS TO INSURE PROPER ROUGH-IN
CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE.
F. PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH
AS GYPSUM BOARD AND MASONRY, MASONRY AND
CONCRETE, COUNTERTOPS AND WALL, ETC.
G. PROVIDE BLOCKING IN GUESTROOMS AT ALL LOCATIONS
WHERE CASEGOODS ARE SPECIFIED TO BE ANCHORED AT
THE WALL. REFERENCE ECISTING HOTEL ARCHITECTURAL
DRAWINGS AND FFE PACKAGE FOR SPECIFICATIONS.
H. PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME
PERIMETERS AND SURROUNDING WALL CONSTRUCTION
UNLESS OTHERWISE INDICATED.
I. PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR
WINDOW AND STOREFRONT FRAME PERIMETERS AND
SURROUNDING CONSTRUCTION UNLESS OTHERWISE
INDICATED.
J. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, AND
ELECTRICAL SHEETS FOR COORDINATION ITEMS.
COORDINATE AS REQUIRED INCLUDING NECESSARY
FRAMING, BLOCKING, ETC.
K. PROVIDE MINIMUM CLEARANCES AT ALL DOORS AND
CORRIDORS PER ADA REQUIREMENTS.
L. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING
SCOPE OF WORK, AND REPORT DISCREPANCIES
IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
M. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL
DIMENSIONS.
N. MATCH EXISTING WAYFINDING, INFORMATIONAL, AND CODE
REQUIRED SIGNAGE SPECIFICATIONS FOR ALL PUBLIC
SPACE, BACK OF HOUSE, GUESTROOMS, AND EXTERIOR
BUILDING SIGNAGE.
O. REFERENCE ROOM FFE PACKAGE FOR ALL WINDOW
TREATMENTS IN GUEST ROOMS. REFERENCE EXISTING
HOTEL DRAWINGS FOR WINDOW TREATMENTSIN LOUNGE
SPACES.
P. ALL PUBLIC SPACE CONCRETE COLUMNS TO RECIEVE GYP
FURRING.
10 10
B
B
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
C
C
D
D
E
E
12 12
B
B
11 11
9 9
8 8
7 7
6 6
5 5
4 4
2 2
C
C
D
D
E
E
B.4
B.4
3 3
10 10
3.3 3.3
B.5
B.5
D.5
D.5
C.5
C.5
9.9 9.9
B.3
B.3
2.1 2.1
B.1
B.1
D.9
D.9
11 11
12 12
F
F
A-201 A1
8.H8.H
7.H7.H
6.H6.H
5.H5.H
4.H4.H
3.H3.H
2.H2.H
9.H9.H
A.H
A.H
1.H1.H
B.H
B.H
C.H
C.H
D.H
D.H
A-202
A1
A1
A-323
1.5.H1.5.H
A-201D1
ASSUME 2" ROOF TO WALL BELLOWS
STYLE EXPANSION JOINT. HOTEL
PARAPET WALL WILL CONTINUE
ALONG THE ENTIRE PERIMETER
INCLUDING WHERE THE HOTEL
MEETS THE EXISTING GARAGE TO
ALLOW FOR ROOFING TERMINATION.
PROVIDE NEW M8A-2H WALL INFILL
BETWEEN EXISTING GARAGE
STRUCTURE AS NEEDED.
A1
A-301
ELEVATOR OVERRUN
ROOF DRAIN WITH OVERFLOW
AND TAPERED INSULATION.
FINAL DRAIN AND TAPERED
INSULATION LAYOUT IS IN
PROGRESS (TYP.)
EXST. GARAGE
12 12
B
B
11 11
9 9
B.4
B.4
10 10
9.9 9.9
8 8
7 7
6 6
5 5
4 4
3.3 3.3
3 3
2 2
B.5
B.5
C
C
2.H2.H
A.H
A.H
1.H1.H
B.H
B.H
C.H
C.H
1.5.H1.5.H
D.H
D.Hhq8
hq8
C.5
C.5
D
D
D.5
D.5
E
E
A.8.H
A.8.H
9.H 9.H
1/4" / 12"
1/4" / 12"
3/8" / 12"
A6
A-322
A5
A-323
1
A-302
8.H8.H
7.H7.H
6.H6.H
5.H5.H
4.H4.H
3.H3.H
2.H2.H
9.H9.H
1.H1.H
1.5.H1.5.H
K K
J J
H H
G G
L L
tcJtcJ
tcHtcH
H.4 H.4
H.8 H.8
K.6 K.6
F.8 F.8
K.8K.8
Ex. H Ex. H
Ex. J Ex. J12 12
11 11
9
9
8
8
7
7
6
6
5
5
4
4
2
2
3
3
10 10
3.3 3.3
9.9 9.9
2.1 2.1
B.5
B.5
D.5
D.5
C.5
C.5
D.9
D.9hq8
hq8
2.8
2.8
2.6
2.6
1.6
1.6
A-203A1
A-203
A4
AP-X071
AP-X06 1
AP-X05
1
A. THESE GENERAL NOTES APPLY TO ROOF DRAWINGS.
B. VERIFY SIZE, LOCATION AND NUMBER OF ROOF
PENETRATIONS INCLUDING VENTS, PIPES, CURBS, ROOF
DRAINS, CONDUITS, ETC. PROVIDE NEW FLASHING AND
SEAL PENETRATIONS WHETHER OR NOT INDICATED ON THE
DRAWINGS.
C. COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY,
WELDING, MASONRY RESTORATION, ETC., PRIOR TO
STARTING ROOFING WORK.
D. VERIFY AND MAINTAIN ROOF SLOPES AND DRAINAGE
PATTERNS. TEST FOR AND CORRECT ANY PONDING
CONDITIONS.
E. REPAIR AND REPLACE ROOFING SYSTEM OR STRUCTURE
DAMAGED BY IMPROPER STORAGE, CONSTRUCTION
ACTIVITIES, OR LACK OF ADEQUATE TEMPORARY
PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO
FINISHES, EQUIPMENT, FURNISHINGS, ETC., RESULTING
FROM LEAKS.
F. NEW BLOCKING SHALL BE PRESERVATIVE-TREATED WOOD.
G. PAINT EXTERIOR LADDERS, BRACKETS, ETC., UNLESS
NOTED OTHERWISE.
H. CAP FASTENERS THAT PENETRATE ROOF DECK IN AREAS
NOT CONCEALED BY CEILINGS WITH WIRE NUTS OR OTHER
MEANS ACCEPTABLE TO ARCHITECT UNLESS OTHERWISE
INDICATED. AREAS SUCH AS JANITOR CLOSETS, STORAGE
ROOMS, MECHANICAL AND ELECTRICAL EQUIPMENT
ROOMS, ETC., ARE EXEMPT FROM THIS REQUIREMENT
UNLESS OTHERWISE INDICATED.
I. REFER TO WALL SECTIONS NOTED ON ROOF PLANS FOR
INFORMATION.
J. REFER TO MECHANICAL DRAWINGS TO COORDINATE ROOF
CONDUCTOR LOCATIONS.
K. OVERALL ROOFING DESIGN CRITERIA FOR PRICING:
a. MATCH TYPICAL ROOFING ASSEMBLY OF EXISTING
HOTEL
b. MINIMUM R-30 INSULATION ON AVERAGE ACROSS THE
FULL ROOF EXTENT
c. TAPERED INSULATION TO SLOPE 1/4" = 1'-0" TO DRAINS,
TYPICAL
A. BASE BID: FULL FIT OUT AS SHOWN IN THE DD PRICING
DOCUMENTS
B. ALTERNATE NO.1: PRICE AS A DEDUCT TO SHELL OUT THE
THIRD HOTEL FLOOR IN ITS ENTIRETY. PROVIDE METAL
STUD FRAMING AND MEP ROUGH-INS. NO DRYWALL
FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT
C. ALTERNATE NO.2: PRICE AS A DEDUCT TO SHELL OUT THE
THIRD AND FOURTH HOTEL FLOORS IN THEIR ENTIRETY.
PROVIDE METAL STUD FRAMING AND MEP ROUGH-INS. NO
DRYWALL FINISHES, FIXTURES, FURNITURE, OR EQUIPMENT
SHEET TITLE
SHEET NUMBER
Owner
Republic Airways Holdings
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect / Landscape Architect
O'Donnell & Naccarato
Structural Engineer
Mechanical / Electrical/ Plumbing Engineer
Civil Engineer
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
Three Parkwood Crossing
450 East 96th Street, Suite 175
Indianapolis, IN 46240
317-580-0402
CIRCLE DESIGN GROUP
9229 Delegates Row #150
Indianapolis, Indiana 46240
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
IT / Technology
DESIGN 27
1650 East 49th Street
Indianapolis, IN 46205
(317) 536-8000
Acoustics
Jaffe Holden
114-A Washington Street
Norwalk, Connecticut 06854
(203) 838-4167
4/
1
8
/
2
0
2
5
3
:
2
6
:
4
3
P
M
A-107
ROOF FLOOR PLAN -
OVERALL
24220.000
REPUBLIC
HOTEL
ADDITION
12201 N. Meridian
Street
Carmel, Indiana
46032
KEYNOTES (SPEC BASED)
GENERAL FLOOR PLAN NOTES
3/32" = 1'-0"A-107
A2 ROOF LEVEL - HOTEL
GENERAL ROOFING NOTES
1 SD PRICING SET 02/21/25
2 DESIGN DEVELOPMENT 04/18/25
04/18/25
ALTERNATE NOTES FOR PRICING