HomeMy WebLinkAboutE6.0DESCRIPTION LTG ZONE CIRCUIT WATTS LTG CONTROL # SCENE 1 SCENE 2 SCENE 3 SCENE 4 SCENE 5 SCENE 6 MORNINGS LUNCH COCKTAIL EVENING CLEANING AFTER HOURS DINNING CHANDELIER Z#1 #1 640 INC DIM#1 OFF 80% 60% 50% OFF OFF DINNING DOWN LTG Z#2 #2 600 MLV DIM#1 50% 70% 60% 50% 50% 50% WALL SCONCE Z#3 #3 300 INC DIM#1 70% 100% 80% 70% OFF OFF GENERAL DINNING LTG Z#4 #4 1100 MLV DIM#1 50% 70% 60% 50% 50% 50% CIRC LIGHTING Z#5 #5 1250 MLV DIM#1 100% 50% 40% 40% 70% 50% COLUMN WALL WASHER Z#6 #6 300 MLV DIM#1 40% 70% 70% 60% OFF OFF BAR CHANDELIER Z#7 #7 360 INC DIM#3 OFF 70% 70% 60% OFF 30% BAR GEN LTG Z#8 #8 250 MLV DIM#3 80% 80% 70% 60% 100% 30% BAR Z#9 #9 1000 MLV DIM#3 80% 80% 70% 60% 100% 30% BAR WALL WASHERS Z#10 #10 100 MLV DIM#3 OFF 70% 70% 60% OFF 30% BAR SEATING Z#11 #11 600 MLV DIM#3 80% 80% 70% 60% 100% 30% BAR WALL SCONCES Z#12 #12 480 INC DIM#3 70% 100% 70% 70% OFF 30% WAITING Z#13 #13 150 MLV DIM#2 100% 70% 70% 50% 100% 30% WAITING Z#14 #14 100 INC DIM#2 100% 70% 70% 40% 100% 30% VEST #134 Z#15 #15 120 MLV DIM#2 100% 70% 70% 60% 50% 30% WOMEN ROOM Z#16 #16 150 FLD DIM#1 100% 70% 60% 50% 100% 50% MEN ROOM Z#17 #17 150 FLD DIM#1 100% 70% 60% 50% 100% 50% PROD KITCH Z#18 #18 750 INC DIM#1 100% 100% 60% 80% 70% 70% PROD KITCH Z#19 #19 750 MLV DIM#1 100% 100% 80% 100% 100% 70% PROD KITCH Z#19 #20 750 MLV DIM#1 100% 100% 100% 100% 100% 70% BREWERY TRACK Z#20 #21 750 MLV DIM#3 OFF 90% 60% OFF SPARE #22 SPARE #23 SPARE #24 NIGHT LIGHTING/BATT UNITS #25 800 INC NON SWITCHED ELV- ELECTRONIC LOW VOLTAGE TOTAL 11450 ` 1. VALUES REPRESENT PROGRAMMED ZONE INTENSITY FLN- FLOURESCENT/NON-DIM WATTS 2. VALUES SHOWN ARE FOR GENERAL REFERENCE. COORDINATE THE EXACT FLD- FLOURESCENT I INTENSITY AND SCENE WITH THE OWNER. INC- INCANDESCENT TOTAL 31.8 MHN- METAL HALID/NON-DIM AMPS MLV- MATIC LOW VOLTAGE NCC- NEON COLD CATHODE OTH- OTHER SPR- SPARE SWI- SWITCH/NON-DIM DIMMING CONTROL SCHEDULE (DCP)