HomeMy WebLinkAboutElectrical Combined - Copy 6E D C B A 1 1.5 2 3 4 5 6 7 7.5 8 W1E W1E W1E X1 W2E W2E X1 L2E L2L2L2EL2 L2E L2L2 L2L2EL2L2E HP-5 HP-2 HP-5 PC5 PC5-1 ARDALAN RESIDENCE 301 STAIR ST1 STAIR ST2 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 SC3 4 L2 HP - 6 1 2 3 3 3 4 3a 3b 3c a a a a a a b c 3c 3d 3e 3a 3b 3g 3h 3g 3h 3d 3e h g h e d e e e 3 35 5 S2 11 hh hh S2 11 a SC3 4 a c c c c c c S2 11 e 6 e 6 6 275 Veterans Way Carmel, Indiana 46032 317.810.1502 Client Information Architect / Interiors / Structural Design Construction Manager Status Revisions Project Information Design Team Member 275 Veterans Way Carmel, Indiana 46032 317.344.8044 2/14/2025 EL103 THIRD FLOOR LIGHTING PLAN - CORE & SHELL Ardalan on Main ISSUED FOR BID AND STATE PERMIT Project Number 24062 331 W. Main Street Carmel, IN 46032 N 1/8" = 1'-0" THIRD FLOOR LIGHTING PLAN1 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LIGHT FIXTURE SCHEDULES AND PANEL SCHEDULES. C LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICE SERVES. D MOUNT EXIT SIGNS ON WALL NOT OVER DOOR +7’-6” AFF. EXIT SIGNS OVER DOOR TO BE +0’-6” ABOVE TOP EDGE OF DOOR FRAME. E `NL’ SYMBOL REPRESENTS NIGH LIGHT AND INDICATES LIGHT WILL REMAIN ON 24/7. F COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS, ARCHITECTURAL ELEVATIONS, MECHANICAL EQUIPMENT, DIFFUSERS, SUPPORTS, PIPING, DUCTWORK AND STRUCTURAL PLANS PRIOR TO ROUGH-IN AND INSTALLATION OF LIGHTS. G LOCATE CEILING MOUNTED OCCUPANCY SENSORS TO PROVIDE COMPLETE COVERAGE OF THE SPACE THEY ARE INSTALLED IN. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE MANUFACTURER. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY FOR PROPER OPERATION. H ALL MOUNTING HEIGHTS NOTED ON THE PLANS ARE TO THE BOTTOM OF THE FIXTURES UNLESS NOTED OTHERWISE. I THE EC IS RESPONSIBLE FOR VERIFYING (FIELD VERIFICATION IF NECESSARY) ALL LINEAR PRODUCT LENGTHS INCLUDING ANY DOWNLIGHTS, WALL SLOTS, PENDANTS, OR ACCENT LIGHTS. J ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHERPROOF AND RAIN TIGHT. K WHERE MULTIPLE SWITCHES ARE SHOWN ADJACENT TO EACH OTHER, GANG TOGETHER IN SINGLE FACEPLACE WITH MULTIPLE SWITCH OUTLET. L CONTRACTOR IS RESPONSIBLE FOR VERIFYING COMPATIBILITY OF LIGHT FIXTURES WITH CEILING MATERIALS, ADJACENT FINISHES AND CONSTRUCTION MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF FIXTURE. SHEET KEYNOTES 1 MOUNT LIGHT FIXTURE AT +12” BELOW TOP OF ELEVATOR SHAFT TO TOP OF LIGHT FIXTURE. COORDINATE FINAL PLACEMENT WITH ELEVATOR MANUFACTURER PRIOR TO ROUGH-IN. 2 PROVIDE LIGHT FIXTURE AND SWITCH ON DEDICATED CIRCUIT FOR ELEVATOR CONTROL PANEL WHICH IS LOCATED IN ELEVATOR JAMB. LOCATE SWITCH NEXT TO ELEVATOR CONTROL PANEL WITHIN REACH OF ELEVATOR DOOR FRAME. SHOWN FOR REFERENCE, COORDINATE WITH ELEVATOR MANUFACTURER TO VERIFY PLACEMENT AND LOCATION PRIOR TO ROUGH-IN. (SHOW ARROW POINTING TO LIGHT FIXTURE AND SWITCH. 3 MOUNT FIXTURE AT 8'-6" AFF (OR STAIR LANDING) TO BOTTOM OF LIGHT FIXTURE. 4 SUSPEND LIGHT FIXTURES IN THIS SPACE AT 10'-0" AFF TO BOTTOM OF LIGHT FIXTURE. 5 PROVIDE 3 WAY SWITCH FOR STUMBLE LIGHTING. 6 LINEAR TAPELIGHT TO BE SURFACE MOUNTED IN THE CAVITY OF THE CORNICE. REFER TO ARCHITECTURAL DRAWINGS AND DETAILS TO VERIFY LENGTHS AND EXACT MOUNTING LOCATION. #DESCRIPTION DATE