Loading...
HomeMy WebLinkAboutEL101 - FIRST FLOOR LIGHTING PLAN - CORE & SHELLM MM J MMMME D C B A 1 1.5 2 3 4 5 6 7 7.5 8 SW2 HP - 3 SW2 HP - 3 SW2 HP - 3 SW2 HP - 3 SW2 HP - 3 SC2 HP - 3 SC1 HP - 3 SC2 HP - 3 L2E L3E L3E L2 L2 L2 L2 L2 L2 L1 L1 L1 L1 L1 L1 L1L1 L1 L1L1 L1 L1 X1 X1 X1 X1 W1E W1E L3 L3 L3EL3 X1 W1E W1E EM1EM1EM1 X1 X3 L2 L2 L2 SW1 HP - 3 SW1 HP - 3 SW1 HP - 3 SW1 HP - 3 SW3 HP - 3 SW3 HP - 3 SW4 HP - 3 SW4 HP - 3 SW1 HP - 3 SW1 HP - 3 X2 X2 W2E W2E SW1 HP - 3 SW1 HP - 3 D2 L4E L4 L4L4 L4 L4E L4L4L4EL4 L4E D4 D4 D3D3 L2E L2E L2 L2L2 L2 L2EL2 L2L2 L2E L2 L2 L2E L2 D4 1 2 2 2 3 4 5 5 HP 6 6 6 6 7 8 8 8 PT1 PT2 PT3 3 3 PT1-1 8 PT2-1 PT3-1 HP-5 RETAIL SPACE 101 RETAIL SPACE 102 TENANT LOBBY 103 GARAGE 112 GARAGE 111 GARAGE 110 GARAGE 109 GARAGE 108 CORRIDOR 106 CORRIDOR 107 WATER ROOM 115 RETAIL SPACE 105 RETAIL SPACE 104 STAIR ST1-1 STAIR ST2-1 ELEC METERS 113 DEMARK 114 HP-5 HP-5 HP-5 HP-5 HP-2 HP-2 HP-5 HP-2 PC5-3 PC1-3 PC2-3 PC3-3 PC4-3 5 SW4 HP - 3 NL NL NL NL NL NL NL 10 10 10 X3 X3 X3 X3 X3 X3 X3 9 9 9 9 9 9 9 X3 9 X3 9 1 1 1 1 1 1 101 9 1 SW5E HP - 25 SW5E HP - 25SW5E HP - 25 SW5E HP - 25 SW5E HP - 25 SW5E HP - 25 10 10 10 SW5E HP - 25 3 SW1 HP - 3 3SW1 HP - 3 3 275 Veterans Way Carmel, Indiana 46032 317.810.1502 Client Information Architect / Interiors / Structural Design Construction Manager Status Revisions Project Information Design Team Member 275 Veterans Way Carmel, Indiana 46032 317.344.8044 2/14/2025 EL101 FIRST FLOOR LIGHTING PLAN - CORE & SHELL Ardalan on Main ISSUED FOR BID AND STATE PERMIT Project Number 24062 331 W. Main Street Carmel, IN 46032 N 1/8" = 1'-0" FIRST FLOOR LIGHTING PLAN1 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LIGHT FIXTURE SCHEDULES AND PANEL SCHEDULES. C LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICE SERVES. D MOUNT EXIT SIGNS ON WALL NOT OVER DOOR +7’-6” AFF. EXIT SIGNS OVER DOOR TO BE +0’-6” ABOVE TOP EDGE OF DOOR FRAME. E `NL’ SYMBOL REPRESENTS NIGH LIGHT AND INDICATES LIGHT WILL REMAIN ON 24/7. F COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS, ARCHITECTURAL ELEVATIONS, MECHANICAL EQUIPMENT, DIFFUSERS, SUPPORTS, PIPING, DUCTWORK AND STRUCTURAL PLANS PRIOR TO ROUGH-IN AND INSTALLATION OF LIGHTS. G LOCATE CEILING MOUNTED OCCUPANCY SENSORS TO PROVIDE COMPLETE COVERAGE OF THE SPACE THEY ARE INSTALLED IN. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE MANUFACTURER. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY FOR PROPER OPERATION. H ALL MOUNTING HEIGHTS NOTED ON THE PLANS ARE TO THE BOTTOM OF THE FIXTURES UNLESS NOTED OTHERWISE. I THE EC IS RESPONSIBLE FOR VERIFYING (FIELD VERIFICATION IF NECESSARY) ALL LINEAR PRODUCT LENGTHS INCLUDING ANY DOWNLIGHTS, WALL SLOTS, PENDANTS, OR ACCENT LIGHTS. J ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHERPROOF AND RAIN TIGHT. K WHERE MULTIPLE SWITCHES ARE SHOWN ADJACENT TO EACH OTHER, GANG TOGETHER IN SINGLE FACEPLACE WITH MULTIPLE SWITCH OUTLET. L CONTRACTOR IS RESPONSIBLE FOR VERIFYING COMPATIBILITY OF LIGHT FIXTURES WITH CEILING MATERIALS, ADJACENT FINISHES AND CONSTRUCTION MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF FIXTURE. SHEET KEYNOTES 1 MOUNT FIXTURE AT 1'-0" ABOVE FINISHED GARAGE DOOR TO BOTTOM OF LIGHT FIXTURE. REFER TO ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION. TYPICAL FOR ALL TYPE 'SW2'. 2 SUSPEND DECORATIVE PENDANT AT APPROXIMATELY 12' AFG TO BOTTOM OF FIXTURE. ARCHITECT TO CONFIRM MOUNTING HEIGHT. 3 MOUNT DECORATIVE WALL SCONCE AT 6'-0" AFG TO CENTER OF LIGHT FIXTURE. TYPICAL OF ALL TYPE 'SW1'. 4 MOUNT RECESSED STEPLIGHT AT 12" ABOVE FINISHED STAIR TREAD TO BOTTOM OF FIXTURE. TYPICAL OF ALL TYPE 'SW3'. 5 MOUNT WALL PACK AT 9'-0" AFG. CONFIRM MOUNTING HEIGHT PRIOR TO ROUGH-IN. 6 MOUNT FIXTURE AT 8'-6" AFF (OR STAIR LANDING) TO BOTTOM OF LIGHT FIXTURE. 7 MOUNT LIGHT FIXTURE AT +12” FROM BOTTOM OF ELEVATOR PIT TO BOTTOM OF LIGHT FIXTURE AND PROVIDE 12 HOUR MECHANICAL TIMER SWITCH. COORDINATE FINAL PLACEMENT WITH ELEVATOR MANUFACTURER PRIOR TO ROUGH-IN 8 MOUNT STUMBLE LIGHTING IN THIS ROOM AT 10'-0" AFF TO BOTTOM OF LIGHT FIXTURE. 9 PENDANT MOUNT EXIT SIGN. MOUNT AT 8'-0" AFF TO BOTTOM OF EXIT SIGN. 10 MOUNT LINEAR EGRESS LIGHT FIXTURE TO THE HIGHEST MULLION AT APPROXIMATELY 13'-6" AFG. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING HEIGHT. #DESCRIPTION DATE 1 ASI-04 5/6/2025 1 1