Loading...
HomeMy WebLinkAboutC8.6 Construction DetailsREVISIONS BA K E R V I L L A G E C8.6 CO N S T R U C T I O N D E T A I L S CONSTRUCTION DETAILSPRE CAST CONCRETE END SECTION NO SWIMMING POND SAFETY SIGN BEDDING AND BACKFILL FOR SSD INDIANAPOLIS - TERRE HAUTE LAFAYETTE - MUNCIE - NEW ALBANY www.hwcengineering.com DOUBLE ROLL CURB INLET 2'x2' BOX INLET TYPICAL SIDEWALK DETAILS CA R M E L , I N NOT FOR CONSTRUCTION PRELIMINARY WATER QUALITY DIVERSION STRUCTURE 102 WATER QUALITY DIVERSION STRUCTURE 122 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date: Rvwed Rvw. Date U.S. Patent No. 11002000 Aqua-Swirl® XCelerator As Shown OFlores Standard Detail 3/28/2022 XC-4 HorseShoe CW XC-4 STD Aqua-Swirl® Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover Detail For Non-Traffic Areas Only NTS 48 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in [1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in [13 mm] 4 1/2 in [114 mm] 14 in [356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl® specification notes. See Site Plan for actual System orientation. Approximate dry (pick) weight: 2000 lbs 900 kg]. Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. XC-4 inlet/outlet pipe size ranges up to 27 in [686 mm]. XC-4 chamber height may vary up to 99 in [2515 mm], depending on inlet/outlet pipe size. Clockwise or counterclockwise orientation as needed. 2 3 3 2 Plan View SCALE 1:40 66 in [1676 mm] 66 in [1676 mm] 2 Octagonal Base Plate Ø54 in [Ø1375 mm] Elevation View SCALE 1:40 84 in [2134 mm] Varies Varies 5 MH Frame [127 mm] n30 in [762 mm] Band Coupler by Manufacturer. (as needed) Riser Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finish grade. 4 4 In l e t Ou t l e t el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies Projected View SCALE 1:70 Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] Lifting Lugs Lifting Lugs Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. n12 in [305 mm] n12 in [305 mm] 50 in [1266 mm] 57 in [1448 mm] n54 in [1372 mm] 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date: Rvwed Rvw. Date U.S. Patent No. 11002000 Aqua-Swirl® XCelerator As Shown OFlores Standard Detail 3/28/2022 XC-6 HorseShoe CW XC-6 STD Aqua-Swirl® Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover Detail For Non-Traffic Areas Only NTS 48 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in [1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in [13 mm] 4 1/2 in [114 mm] 14 in [356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl® specification notes. See Site Plan for actual System orientation. Approximate dry (pick) weight: 3000 lbs [1400 kg]. Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. XC-6 inlet/outlet pipe size ranges up to 36 in [914 mm]. XC-6 chamber height may vary up to 133 in [3378 mm], depending on inlet/outlet pipe size. Clockwise or counterclockwise orientation as needed. 2 3 3 2 Plan View SCALE 1:40 90 in [2286 mm] 90 in [2286 mm] 2 Octagonal Base Plate Ø78 in [Ø1985 mm] Elevation View SCALE 1:40 112 in [2845 mm] Varies Varies 5 MH Frame [127 mm] n30 in [762 mm] Band Coupler by Manufacturer. (as needed) Riser Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finish grade. 4 4 In l e t Ou t l e t el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies Projected View SCALE 1:70 Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] Lifting LugsLifting Lugs Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. n15 in [381 mm] n15 in [381 mm] 73 in [1858 mm] 79 in [2007 mm] n78 in [1981 mm] MECHANICAL WATER QUALITY UNIT DETAIL